Literature DB >> 20199910

Computer-assisted scan protocol and reconstruction (CASPAR)-reduction of image noise and patient dose.

Jonathan Sperl1, Dirk Beque, Bernhard Claus, Bruno De Man, Bob Senzig, Martin Brokate.   

Abstract

X-ray computed tomography is a powerful medical imaging device. It allows high-resolution 3-D visualization of the human body. However, one drawback is the health risk associated with ionizing radiation. Simply downscaling the radiation intensities over the entire scan results in increased quantum noise. This paper proposes the concept of computer-assisted scan protocol and reconstruction. More specifically, we propose a method to compute patient and task-specific intensity profiles that achieve an optimal tradeoff between radiation dose and image quality. Therefore, reasonable image variance and dose metrics are derived. Conventional third-generation systems as well as inverted geometry concepts are considered. Two dose/noise minimization problems are formulated and solved by an efficient algorithm providing optimized milliampere (mA)-profiles. Thorax phantom simulations demonstrate the promising advantage of this technique: in this particular example, the dose is reduced by 53% for third-generation systems and by 86% for an inverted geometry in comparison to a sinusoidal mA-profile at a constant upper noise limit.

Entities:  

Mesh:

Year:  2010        PMID: 20199910     DOI: 10.1109/TMI.2009.2034515

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  14 in total

1.  Direct two-dimensional reconstruction algorithm for an inverse-geometry CT system.

Authors:  Jongduk Baek; Norbert J Pelc
Journal:  Med Phys       Date:  2009-02       Impact factor: 4.071

2.  Design of a digital beam attenuation system for computed tomography: part I. System design and simulation framework.

Authors:  Timothy P Szczykutowicz; Charles A Mistretta
Journal:  Med Phys       Date:  2013-02       Impact factor: 4.071

3.  The feasibility of an inverse geometry CT system with stationary source arrays.

Authors:  Scott S Hsieh; Joseph A Heanue; Tobias Funk; Waldo S Hinshaw; Brian P Wilfley; Edward G Solomon; Norbert J Pelc
Journal:  Med Phys       Date:  2013-03       Impact factor: 4.071

4.  The feasibility of a piecewise-linear dynamic bowtie filter.

Authors:  Scott S Hsieh; Norbert J Pelc
Journal:  Med Phys       Date:  2013-03       Impact factor: 4.071

5.  Dose reduction using a dynamic, piecewise-linear attenuator.

Authors:  Scott S Hsieh; Dominik Fleischmann; Norbert J Pelc
Journal:  Med Phys       Date:  2014-02       Impact factor: 4.071

6.  Control algorithms for dynamic attenuators.

Authors:  Scott S Hsieh; Norbert J Pelc
Journal:  Med Phys       Date:  2014-06       Impact factor: 4.071

7.  Design of a digital beam attenuation system for computed tomography. Part II. Performance study and initial results.

Authors:  Timothy P Szczykutowicz; Charles A Mistretta
Journal:  Med Phys       Date:  2013-02       Impact factor: 4.071

8.  Fast analytical approach of application specific dose efficient spectrum selection for diagnostic CT imaging and PET attenuation correction.

Authors:  Xue Rui; Yannan Jin; Paul F FitzGerald; Mingye Wu; Adam M Alessio; Paul E Kinahan; Bruno De Man
Journal:  Phys Med Biol       Date:  2016-10-18       Impact factor: 3.609

9.  A multi-source inverse-geometry CT system: initial results with an 8 spot x-ray source array.

Authors:  Jongduk Baek; Bruno De Man; Jorge Uribe; Randy Longtin; Daniel Harrison; Joseph Reynolds; Bogdan Neculaes; Kristopher Frutschy; Louis Inzinna; Antonio Caiafa; Robert Senzig; Norbert J Pelc
Journal:  Phys Med Biol       Date:  2014-02-20       Impact factor: 3.609

10.  Experimental realization of fluence field modulated CT using digital beam attenuation.

Authors:  T P Szczykutowicz; C A Mistretta
Journal:  Phys Med Biol       Date:  2014-02-20       Impact factor: 3.609

View more