Literature DB >> 20196177

Optimization of electrospray interface and quadrupole ion trap mass spectrometer parameters in pesticide liquid chromatography/electrospray ionization mass spectrometry analysis.

Anneli Kruve1, Koit Herodes, Ivo Leito.   

Abstract

Optimization of both the ionization process and ion transportation in the mass spectrometer is of crucial importance in order to achieve high sensitivity and low detection limits and acceptable accuracy in liquid chromatography/electrospray ionization mass spectrometry (LC/ESI-MS) analysis. In this paper four optimization procedures of electrospray interface and quadrupole ion-trap mass spectrometer parameters (ESI-MS) (nebulizer gas and drying gas flow rate, end plate voltage, capillary voltage, skimmer voltage, octopoles direct current and radio frequency, trap drive and lens voltages) were studied on three pesticides--thiabendazole, aldicarb and imazalil. The results demonstrate that the methodology of optimization strongly influences the effectiveness of finding true optima of the operating parameters. Both eluent flow rate and composition during optimization have to mimic the situation during real analysis as closely as possible in order to achieve parameters giving the highest sensitivity. Therefore, post-column addition of analyte to the mobile phase identical in composition to the one in which analyte elutes during real analysis combined with software-based optimization was found to be the most effective and fastest method for achieving intensity maxima. The parameters most strongly affecting ion formation and transportation, hence sensitivity, were capillary voltage, direct current of the first octopole, trap drive and the second lens for all pesticides under study. In addition to sensitivity and detection limit matrix effect was considered in the optimization process. It was found that the matrix effect can be reduced but not eliminated by adjusting the ESI and MS parameters. The optimal parameters from the point of view of the matrix effect can only be found with factorial design. Parameters giving higher sensitivity tended to be more affected by matrix effect causing higher ionization suppression by co-eluting compounds. 2010 John Wiley & Sons, Ltd.

Entities:  

Year:  2010        PMID: 20196177     DOI: 10.1002/rcm.4470

Source DB:  PubMed          Journal:  Rapid Commun Mass Spectrom        ISSN: 0951-4198            Impact factor:   2.419


  7 in total

1.  Determination of glyphosate in surface water with high organic matter content.

Authors:  Vahur Toss; Ivo Leito; Sergei Yurchenko; Rene Freiberg; Anneli Kruve
Journal:  Environ Sci Pollut Res Int       Date:  2017-02-13       Impact factor: 4.223

2.  Resolving the Discrepancies Between Empirical and Rayleigh Charge Limiting Models for Globular Proteins.

Authors:  Karen C B De Freitas
Journal:  J Am Soc Mass Spectrom       Date:  2018-07-24       Impact factor: 3.109

3.  Enhanced nebulization efficiency of electrospray mass spectrometry: improved sensitivity and detection limit.

Authors:  Anneli Kruve; Ivo Leito; Koit Herodes; Asko Laaniste; Rünno Lõhmus
Journal:  J Am Soc Mass Spectrom       Date:  2012-09-22       Impact factor: 3.109

4.  Optimization of the Ion Source-Mass Spectrometry Parameters in Non-Steroidal Anti-Inflammatory and Analgesic Pharmaceuticals Analysis by a Design of Experiments Approach.

Authors:  Paula Paíga; Luís M S Silva; Cristina Delerue-Matos
Journal:  J Am Soc Mass Spectrom       Date:  2016-08-15       Impact factor: 3.109

5.  Impact of instrumental settings in electrospray ionization ion trap mass spectrometry on the analysis of O-methoxyethyl-O-methyl cellulose: a comprehensive quantitative evaluation.

Authors:  Sarah Schleicher; Dominik Horoba; Philip Krafzig; Petra Mischnick
Journal:  Anal Bioanal Chem       Date:  2022-05-03       Impact factor: 4.478

Review 6.  Optimizing Mass Spectrometry Analyses: A Tailored Review on the Utility of Design of Experiments.

Authors:  Elizabeth S Hecht; Ann L Oberg; David C Muddiman
Journal:  J Am Soc Mass Spectrom       Date:  2016-03-07       Impact factor: 3.109

7.  Impact of instrumental settings in electrospray ionization ion trap mass spectrometry on the analysis of multi-CH3-/CD3-isotopologs in cellulose ether analysis: a quantitative evaluation.

Authors:  Sarah Schleicher; Inka-Rosalia Lottje; Petra Mischnick
Journal:  Anal Bioanal Chem       Date:  2021-12-16       Impact factor: 4.142

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.