Literature DB >> 20194317

Revision arthroscopic rotator cuff repair: repair integrity and clinical outcome.

Jay D Keener1, Anthony S Wei, H Mike Kim, Edward S Paxton, Sharlene A Teefey, Leesa M Galatz, Ken Yamaguchi.   

Abstract

BACKGROUND: Literature regarding the outcomes of revision rotator cuff repair is limited. The purposes of the present study were to report the tendon repair integrity and clinical outcomes for a cohort of patients following revision arthroscopic rotator cuff repair and to examine factors related to tendon healing and the influence of healing on clinical outcomes.
METHODS: Twenty-one of twenty-nine consecutive revision arthroscopic rotator cuff repairs with a minimum of two years of postoperative follow-up were retrospectively reviewed. Outcomes were evaluated on the basis of a visual analog pain scale, the range of motion of the shoulder, the Simple Shoulder Test, the American Shoulder and Elbow Surgeons score, and the Constant score. Ultrasonography was used to examine repair integrity at a minimum of one year following surgery. Ten shoulders underwent arthroscopic repair of a recurrent single-tendon posterior rotator cuff tear, whereas eleven shoulders had repair of both the supraspinatus and infraspinatus.
RESULTS: The mean age of the twenty-one subjects was 55.6 years; thirteen subjects were male and eight were female. Complete preoperative and postoperative clinical data were available for nineteen subjects after an average duration of follow-up of thirty-three months. Significant improvements were seen in terms of postoperative pain (p < 0.05), the Simple Shoulder Test score (p < 0.05), the American Shoulder and Elbow Surgeons function (p < 0.05) and total scores (p < 0.05), active forward elevation (p < 0.05), and active external rotation (p < 0.05). Postoperative ultrasound data were available for all twenty-one shoulders after a mean duration of follow-up of twenty-five months. Ten (48%) of the twenty-one shoulders had an intact repair. Seven (70%) of the ten single-tendon repairs were intact, compared with three (27%) of the eleven supraspinatus/infraspinatus repairs (p = 0.05). Patient age (p < 0.05) and the number of torn tendons (p = 0.05) had significant effects on postoperative tendon repair integrity. Shoulders with an intact repair had better postoperative Constant scores (p < 0.05) and scapular plane elevation strength (p < 0.05) in comparison with those with a recurrent tear.
CONCLUSIONS: Revision arthroscopic rotator cuff repair results in reliable pain relief and improvement in shoulder function in selected cases. Approximately half of the revision repairs can be expected to be intact at a minimum of one year following surgery. Patient age and the number of torn tendons are related to postoperative tendon integrity. The postoperative integrity of the rotator cuff can have a significant influence on shoulder abduction strength and the Constant score.

Entities:  

Mesh:

Year:  2010        PMID: 20194317     DOI: 10.2106/JBJS.I.00267

Source DB:  PubMed          Journal:  J Bone Joint Surg Am        ISSN: 0021-9355            Impact factor:   5.284


  22 in total

1.  Management of complications after rotator cuff surgery.

Authors:  Stephen A Parada; Matthew F Dilisio; Colin D Kennedy
Journal:  Curr Rev Musculoskelet Med       Date:  2015-03

2.  Arthroscopic transosseous rotator cuff repair: technical note, outcomes, and complications.

Authors:  Eric M Black; Albert Lin; Uma Srikumaran; Nitin Jain; Michael T Freehill
Journal:  Orthopedics       Date:  2015-05       Impact factor: 1.390

Review 3.  [Recurrent defects of the rotary cuff : Causes and therapeutic strategies].

Authors:  M Scheibel
Journal:  Oper Orthop Traumatol       Date:  2012-11       Impact factor: 1.154

4.  The cost-effectiveness of single-row compared with double-row arthroscopic rotator cuff repair.

Authors:  James W Genuario; Ryan P Donegan; Daniel Hamman; John-Erik Bell; Martin Boublik; Theodore Schlegel; Anna N A Tosteson
Journal:  J Bone Joint Surg Am       Date:  2012-08-01       Impact factor: 5.284

5.  Rotator cuff re-tear or non-healing: histopathological aspects and predictive factors.

Authors:  C Chillemi; V Petrozza; L Garro; B Sardella; R Diotallevi; A Ferrara; A Gigante; C Di Cristofano; A Castagna; C Della Rocca
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-04-30       Impact factor: 4.342

6.  Clinical outcome and prognostic factors of revision arthroscopic rotator cuff tear repair.

Authors:  Maria Valencia Mora; Diana Morcillo Barrenechea; Maria Dolores Martín Ríos; Antonio M Foruria; Emilio Calvo
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2016-12-29       Impact factor: 4.342

7.  Does augmentation with a reinforced fascia patch improve rotator cuff repair outcomes?

Authors:  Andrew R Baker; Jesse A McCarron; Carmela D Tan; Joseph P Iannotti; Kathleen A Derwin
Journal:  Clin Orthop Relat Res       Date:  2012-09       Impact factor: 4.176

Review 8.  Scaffolds for tendon and ligament repair and regeneration.

Authors:  Anthony Ratcliffe; David L Butler; Nathaniel A Dyment; Paul J Cagle; Christopher S Proctor; Seena S Ratcliffe; Evan L Flatow
Journal:  Ann Biomed Eng       Date:  2015-02-04       Impact factor: 3.934

9.  Revision wrist arthroscopy after failed primary arthroscopic treatment.

Authors:  Eugene Jang; Jonathan R Danoff; Rebecca A Rajfer; Melvin P Rosenwasser
Journal:  J Wrist Surg       Date:  2014-02

10.  [Arthroscopic rotator cuff repair with patch augmentation].

Authors:  M Flury
Journal:  Oper Orthop Traumatol       Date:  2012-11       Impact factor: 1.154

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.