Literature DB >> 20192149

Superior gluteal artery injury during iliosacral screw placement due to aberrant anatomy.

Meir Marmor1, Terry Lynch, Amir Matityahu.   

Abstract

Percutaneous iliosacral screws are considered the standard of care for disruptions of the sacroiliac joint. This article describes a case of iatrogenic injury to the superior gluteal artery during iliosacral screw insertion and analyzes the possible reasons for this complication.A 32-year-old man diagnosed with an unstable pelvic ring injury underwent percutaneous fixation of the right sacroiliac joint. A 2-cm skin incision was made, and a straight cannulated awl was placed with the tip directly lateral to the S1 body. A guide wire was inserted and a partially threaded 6.5-mm cannulated screw with a washer was then placed over the guide wire and was found to be in excellent position. At this time, increased bleeding from the incision was observed. The incision was enlarged and dissection was carried down through the muscle. The bleeding vessel could not be visualized. Therefore, the wound was packed with sponges, and coil embolization of the right superficial gluteal artery was successfully performed.Analysis of the angiography reveled that our patient's superficial branch of the superior gluteal artery measured more than twice the average length reported in a previous anatomic study. We believe this is the first case of superior gluteal artery bleeding due to aberrant superior gluteal artery anatomy. When planning iliosacral screw insertion, the possibility of anatomical variance of the superior gluteal artery should be acknowledged and sought after in preoperative angiography, when available. Copyright 2010, SLACK Incorporated.

Entities:  

Mesh:

Year:  2010        PMID: 20192149     DOI: 10.3928/01477447-20100104-26

Source DB:  PubMed          Journal:  Orthopedics        ISSN: 0147-7447            Impact factor:   1.390


  15 in total

1.  Biomechanical comparison of three types of internal fixation in a type C zone II pelvic fracture model.

Authors:  Tao Wu; Wei Chen; Xu Li; Qi Zhang; Hong-Zhi Lv; Ying-Ze Zhang
Journal:  Int J Clin Exp Med       Date:  2015-02-15

Review 2.  Robotic versus freehand S2 alar iliac fixation: in-depth technical considerations.

Authors:  Joseph L Laratta; Jamal N Shillingford; Joshua S Meredith; Lawrence G Lenke; Ronald A Lehman; Jeffrey L Gum
Journal:  J Spine Surg       Date:  2018-09

3.  Therapeutic effects of minimally invasive adjustable and locking compression plate for unstable pelvic fractures via posterior approach.

Authors:  Tao Wu; Wei Chen; Qi Zhang; Xu Li; Hong-Zhi Lv; Guang Yang; Ying-Ze Zhang
Journal:  Int J Clin Exp Med       Date:  2015-01-15

4.  Management of the open book APC II pelvis: Survey results from pelvic and acetabular surgeons in the United Kingdom.

Authors:  James R Gill; Colin Murphy; Ben Quansah; Andrew Carrothers
Journal:  J Orthop       Date:  2017-08-09

5.  Superior Gluteal Artery Injury during Percutaneous Iliosacral Screw Fixation: A Case Report.

Authors:  Suk Kang; Phil Hyun Chung; Jong Pil Kim; Young Sung Kim; Ho Min Lee; Gyeong Soo Eum
Journal:  Hip Pelvis       Date:  2015-03-31

6.  The percutaneous stabilisation of the sacroiliac joint with hollow modular anchorage screws: a prospective outcome study.

Authors:  Lyndon W Mason; Iqroop Chopra; Khitish Mohanty
Journal:  Eur Spine J       Date:  2013-05-18       Impact factor: 3.134

7.  Osteology of the ilium revised: illuminating the clinical relevance.

Authors:  Alexander von Glinski; Sven Frieler; Emre Yilmaz; Basem Ishak; Ryan Goodmanson; Joe Iwanaga; Thomas A Schildhauer; Jens R Chapman; Rod J Oskouian; Keith Mayo; R Shane Tubbs
Journal:  Eur J Trauma Emerg Surg       Date:  2020-09-04       Impact factor: 3.693

8.  Superior gluteal artery injury risk from third sacral segment transsacral screw insertion.

Authors:  Jonathan G Eastman; Quintin A Kuse; Milton L Chip Routt; Trevor J Shelton; Mark R Adams
Journal:  Eur J Orthop Surg Traumatol       Date:  2021-07-05

9.  Anatomic relationship between S2 sacroiliac screws' entry points and pelvic external branches of superior gluteal artery.

Authors:  Yong Zhao; Wenliang Li; Wei Lian; Jingning Li; Dexin Zou; Xiujiang Sun; Gong Cheng; Shengjie Dong; Tao Sun
Journal:  Eur J Trauma Emerg Surg       Date:  2021-03-06       Impact factor: 3.693

10.  Biomechanical Comparison of Two Kinds of Internal Fixation in a Type C Zone II Pelvic Fracture Model.

Authors:  Tao Wu; Wei Chen; Qi Zhang; Zhan-Le Zheng; Hong-Zhi Lyu; Yun-Wei Cui; Xiao-Dong Cheng; Ying-Ze Zhang; Yan-Jiang Yang
Journal:  Chin Med J (Engl)       Date:  2015-09-05       Impact factor: 2.628

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.