Literature DB >> 20192143

Computer-assisted 3-dimensional anthropometry of the scaphoid.

Wolfgang Pichler1, Gunther Windisch, Gottfried Schaffler, Nima Heidari, Katrin Dorr, Wolfgang Grechenig.   

Abstract

Scaphoid fracture fixation using a cannulated headless compression screw and the Matti-Russe procedure for the treatment of scaphoid nonunions are performed routinely. Surgeons performing these procedures need to be familiar with the anatomy of the scaphoid. A literature review reveals relatively few articles on this subject. The goal of this anatomical study was to measure the scaphoid using current technology and to discuss the findings with respect to the current, relevant literature.Computed tomography scans of 30 wrists were performed using a 64-slice SOMATOM Sensation CT system (resolution 0.6 mm) (Siemens Medical Solutions Inc, Malvern, Pennsylvania). Three-dimensional reconstructions from the raw data were generated by MIMICS software (Materialise, Leuven, Belgium). The scaphoid had a mean length of 26.0 mm (range, 22.3-30.7 mm), and men had a significantly longer (P<.001) scaphoid than women (27.861.6 mm vs 24.561.6 mm, respectively). The width and height were measured at 3 different levels for volume calculations, resulting in a mean volume of 3389.5 mm(3). Men had a significantly larger (P<.001) scaphoid volume than women (4057.86740.7 mm(3) vs 2846.56617.5 mm(3), respectively).We found considerable variation in the length and volume of the scaphoid in our cohort. We also demonstrated a clear correlation between scaphoid size and sex. Surgeons performing operative fixation of scaphoid fractures and corticocancellous bone grafting for nonunions need to be familiar with these anatomical variations. Copyright 2010, SLACK Incorporated.

Entities:  

Mesh:

Year:  2010        PMID: 20192143     DOI: 10.3928/01477447-20100104-16

Source DB:  PubMed          Journal:  Orthopedics        ISSN: 0147-7447            Impact factor:   1.390


  7 in total

1.  Determination of the Central Axis of the Scaphoid.

Authors:  Dennis J Heaton; Thomas Trumble; Diana Rhodes
Journal:  J Wrist Surg       Date:  2015-08

Review 2.  Computer-assisted Surgery for Scaphoid Fracture.

Authors:  Zi-Run Xiao; Ge Xiong
Journal:  Curr Med Sci       Date:  2018-12-07

3.  Volume slicing of cone-beam computed tomography images for navigation of percutaneous scaphoid fixation.

Authors:  Erin J Smith; Hisham A Al-Sanawi; Braden Gammon; Paul J St John; David R Pichora; Randy E Ellis
Journal:  Int J Comput Assist Radiol Surg       Date:  2011-06-25       Impact factor: 2.924

4.  Computer-assisted percutaneous scaphoid fixation: concepts and evolution.

Authors:  Erin J Smith; Randy E Ellis; David R Pichora
Journal:  J Wrist Surg       Date:  2013-11

5.  Three-Dimensional Printed Targeting Device for Scaphoid Fracture Fixation.

Authors:  Matthew C DeWolf; Alexander Hartov; Thomas A Fortney; Lance G Warhold
Journal:  Hand (N Y)       Date:  2020-02-28

6.  Quantification of contralateral differences of the scaphoid: a comparison of bone geometry in three dimensions.

Authors:  Claudio Letta; Andreas Schweizer; Philipp Fürnstahl
Journal:  Anat Res Int       Date:  2014-02-11

7.  3D computational anatomy of the scaphoid and its waist for use in fracture treatment.

Authors:  Marc-Daniel Ahrend; Teun Teunis; Hansrudi Noser; Florian Schmidutz; Geoff Richards; Boyko Gueorguiev; Lukas Kamer
Journal:  J Orthop Surg Res       Date:  2021-03-24       Impact factor: 2.359

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.