Literature DB >> 20191267

Exploiting automatic on-line renewable molecularly imprinted solid-phase extraction in lab-on-valve format as front end to liquid chromatography: application to the determination of riboflavin in foodstuffs.

Hugo M Oliveira1, Marcela A Segundo2, José L F C Lima1, Manuel Miró3, Victor Cerdà3.   

Abstract

In the present work, it is proposed, for the first time, an on-line automatic renewable molecularly imprinted solid-phase extraction (MISPE) protocol for sample preparation prior to liquid chromatographic analysis. The automatic microscale procedure was based on the bead injection (BI) concept under the lab-on-valve (LOV) format, using a multisyringe burette as propulsion unit for handling solutions and suspensions. A high precision on handling the suspensions containing irregularly shaped molecularly imprinted polymer (MIP) particles was attained, enabling the use of commercial MIP as renewable sorbent. The features of the proposed BI-LOV manifold also allowed a strict control of the different steps within the extraction protocol, which are essential for promoting selective interactions in the cavities of the MIP. By using this on-line method, it was possible to extract and quantify riboflavin from different foodstuff samples in the range between 0.450 and 5.00 mg L(-1) after processing 1,000 microL of sample (infant milk, pig liver extract, and energy drink) without any prior treatment. For milk samples, LOD and LOQ values were 0.05 and 0.17 mg L(-1), respectively. The method was successfully applied to the analysis of two certified reference materials (NIST 1846 and BCR 487) with high precision (RSD < 5.5%). Considering the downscale and simplification of the sample preparation protocol and the simultaneous performance of extraction and chromatographic assays, a cost-effective and enhanced throughput (six determinations per hour) methodology for determination of riboflavin in foodstuff samples is deployed here.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20191267     DOI: 10.1007/s00216-010-3522-1

Source DB:  PubMed          Journal:  Anal Bioanal Chem        ISSN: 1618-2642            Impact factor:   4.142


  3 in total

Review 1.  Pharmaceutical and biomedical applications of affinity chromatography: recent trends and developments.

Authors:  David S Hage; Jeanethe A Anguizola; Cong Bi; Rong Li; Ryan Matsuda; Efthimia Papastavros; Erika Pfaunmiller; John Vargas; Xiwei Zheng
Journal:  J Pharm Biomed Anal       Date:  2012-01-14       Impact factor: 3.935

Review 2.  Optimising factors affecting solid phase extraction performances of molecular imprinted polymer as recent sample preparation technique.

Authors:  Gabriella Josephine Maranata; Natasha Octavianti Surya; Aliya Nur Hasanah
Journal:  Heliyon       Date:  2021-01-28

3.  Online Coupling of Lab-on-Valve Format to Amperometry Based on Polyvinylpyrrolidone-Doped Carbon Paste Electrode and Its Application to the Analysis of Morin.

Authors:  Yang Wang; Guojun Yao; Jie Tang; Chun Yang; Qin Xu; Xiaoya Hu
Journal:  J Anal Methods Chem       Date:  2012-04-05       Impact factor: 2.193

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.