Literature DB >> 20189303

A simple and rapid new dispersive liquid-liquid microextraction based on solidification of floating organic drop combined with inductively coupled plasma-optical emission spectrometry for preconcentration and determination of aluminium in water samples.

Mohammad Rezaee1, Yadollah Yamini, Alireza Khanchi, Mohammad Faraji, Abolfazl Saleh.   

Abstract

A new dispersive liquid-liquid microextraction method based on solidification of floating organic drop (DLLME-SFO) combined with inductively coupled plasma-optical emission spectrometry (ICP-OES) was developed for the determination of aluminium. An appropriate mixture of acetone and 1-undecanol was injected rapidly into the aqueous sample containing aluminium-morin complex and as a result cloudy mixture was formed. After centrifugation, the test tube was cooled for 5 min. The solidified 1-undecanol on top of the solution was transferred into a suitable vial. Then, 100 microL of it was dissolved in 100 microL of 1-propanol and finally injected into the ICP-OES. Under the optimum conditions, the enhancement factor of 128 was obtained for only 20.0 mL of the water sample. The calibration graph was linear in the range of 1.0-250.0 microg L(-1) with the limit of detection of 0.8 microg L(-1). The relative standard deviation (RSD) for five replicate measurements of aluminium was 4.5%. Copyright 2010 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20189303     DOI: 10.1016/j.jhazmat.2010.02.006

Source DB:  PubMed          Journal:  J Hazard Mater        ISSN: 0304-3894            Impact factor:   10.588


  4 in total

1.  Determination of aluminium in groundwater samples by GF-AAS, ICP-AES, ICP-MS and modelling of inorganic aluminium complexes.

Authors:  Marcin Frankowski; Anetta Zioła-Frankowska; Iwona Kurzyca; Karel Novotný; Tomas Vaculovič; Viktor Kanický; Marcin Siepak; Jerzy Siepak
Journal:  Environ Monit Assess       Date:  2011-01-20       Impact factor: 2.513

2.  Solid-phase extraction and separation procedure for trace aluminum in water samples and its determination by high-resolution continuum source flame atomic absorption spectrometry (HR-CS FAAS).

Authors:  Harun Ciftci; Cigdem Er
Journal:  Environ Monit Assess       Date:  2012-06-29       Impact factor: 2.513

3.  Graphene Assisted in the Analysis of Coumarins in Angelicae Pubescentis Radix by Dispersive Liquid-Liquid Microextraction Combined with 1H-qNMR.

Authors:  Yanmei Feng; Qian Li; Daiyu Qiu; Guichen Li
Journal:  Molecules       Date:  2021-04-21       Impact factor: 4.411

Review 4.  Application of hollow fiber liquid phase microextraction and dispersive liquid-liquid microextraction techniques in analytical toxicology.

Authors:  Vahid Sharifi; Ali Abbasi; Anahita Nosrati
Journal:  J Food Drug Anal       Date:  2016-01-07       Impact factor: 6.157

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.