Literature DB >> 20188962

Studies on the stripping voltammetric determination and speciation of chromium at a rotating-disc bismuth film electrode.

E O Jorge1, M M Rocha, I T E Fonseca, M M M Neto.   

Abstract

An adsorptive stripping voltammetric protocol coupled with a rotating-disc bismuth film electrode for the determination and speciation of chromium (III) and chromium (VI) in the presence of diethylenetriaminepentaacetic acid (DTPA) is presented. The developed methodology involves a mass-transport controlled preconcentration step, during which a Cr(III)-DTPA complex is adsorbed onto a pre-plated rotating-disc bismuth film electrode held at -0.4V, followed by a reductive square wave stripping scan. At -1.07 V vs. Ag/AgCl, a peak is recorded due to the catalytic reduction of Cr(III)-DTPA to Cr(II)-DTPA. As a result of different chemical behaviours of Cr(III) and Cr(VI) in the presence of DTPA, the corresponding voltammetric signals presented different stabilities in time. A univariate optimization study was performed with several experimental parameters as variables. For Cr(VI) and total chromium, Cr(III)+Cr(VI), an accumulation time of 60s at -0.4V vs. Ag/AgCl resulted in detection limits of 0.336 and 0.414 nM and quantification limits of 1.12 and 1.40 nM, respectively. The relative standard deviation for 10 measurements of 5.0 nM chromate was 2.4%. Interference of other electroactive trace metals and surfactants was considered. A simple speciation scheme was proposed and satisfactorily applied to Cr(III) and Cr(VI) determinations in river water samples. (c) 2009 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20188962     DOI: 10.1016/j.talanta.2009.12.043

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  4 in total

1.  Improved Bi Film Wrapped Single Walled Carbon Nanotubes for Ultrasensitive Electrochemical Detection of Trace Cr(VI).

Authors:  Ruizhuo Ouyang; Wangyao Zhang; Shilin Zhou; Zi-Ling Xue; Lina Xu; Yingying Gu; Yuqing Miao
Journal:  Electrochim Acta       Date:  2013-12-15       Impact factor: 6.901

2.  Gold nanostar-based voltammetric sensor for chromium(VI).

Authors:  Susom Dutta; Guinevere Strack; Pradeep Kurup
Journal:  Mikrochim Acta       Date:  2019-10-31       Impact factor: 5.833

3.  Electrogenerated Chemiluminescence Behavior of Au nanoparticles-hybridized Pb (II) metal-organic framework and its application in selective sensing hexavalent chromium.

Authors:  Hongmin Ma; Xiaojian Li; Tao Yan; Yan Li; Haiyang Liu; Yong Zhang; Dan Wu; Bin Du; Qin Wei
Journal:  Sci Rep       Date:  2016-02-23       Impact factor: 4.379

4.  On-line micro column preconcentration system based on amino bimodal mesoporous silica nanoparticles as a novel adsorbent for removal and speciation of chromium (III, VI) in environmental samples.

Authors:  Hamid Shirkhanloo; Aisan Khaligh; Farideh Golbabaei; Zargham Sadeghi; Amir Vahid; Alimorad Rashidi
Journal:  J Environ Health Sci Eng       Date:  2015-05-22
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.