Literature DB >> 20188375

Studies on the effect of column angle in centrifugal helix counter-current chromatography.

Yi Yang1, Dongyu Gu, Haji Akber Aisa, Yoichiro Ito.   

Abstract

The performance of the coiled column of centrifugal counter-current chromatography was investigated by changing the angle between column axis and centrifugal force in the separation of dipeptides or DNP-amino acids each with suitable two-phase solvent systems. In general, retention of the stationary phase (Sf) decreased, and peak resolution (Rs) increased as the column angle was increased. The first series of experiments was performed using a polar two-phase solvent system composed of 1-butanol-acetic acid-water (4:1:5, v/v/v) to separate two dipeptide samples, Trp-Tyr and Val-Tyr, at a flow rate of 1 ml/min at 1, 000 rpm. When the column angle was changed from 0 degrees to 90 degrees , Rs increased from 1.05 (Sf=60.1%) to 1.17 (Sf=38.7%) with the lower phase mobile and from 1.02 (Sf=67.8%) to 1.14 (Sf=47.4%) with the upper phase mobile, respectively. The second series of experiments was similarly performed with a more hydrophobic two-phase solvent system composed of hexane-ethyl acetate-methanol-0.1M hydrochloric acid (1:1:1:1, v/v/v/v) to separate three DNP-amino acids, DNP-glu, DNP-beta-ala and DNP-ala, at a flow rate of 1 ml/min at 1, 000 rpm. When the column angle was changed from 0 degrees to 90 degrees , Rs increased from 1.38 (1st peak/2nd peak) and 1.20 (2nd peak/3rd peak) (Sf=61.1%) to 1.66 and 1.45 (Sf=34.4%) with the lower phase mobile and from 1.14 and 0.63 (Sf=72.2%) to 1.53 and 0.87 (Sf=51.1%) with the upper phase mobile, respectively. The overall results of our studies indicate that increasing the column angle against the radially acting centrifugal force enhances the mixing of two phases in the column to improve the peak while decreasing the stationary phase retention by interrupting the laminar flow of the mobile phase. Published by Elsevier B.V.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20188375      PMCID: PMC2838955          DOI: 10.1016/j.chroma.2010.02.003

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  6 in total

Review 1.  Role of counter-current chromatography in the modernisation of Chinese herbal medicines.

Authors:  Ian A Sutherland; Derek Fisher
Journal:  J Chromatogr A       Date:  2008-12-09       Impact factor: 4.759

Review 2.  Countercurrent chromatography: people and applications.

Authors:  A Berthod; M J Ruiz-Angel; S Carda-Broch
Journal:  J Chromatogr A       Date:  2008-10-22       Impact factor: 4.759

3.  APPLICATION OF PREPARATIVE HIGH-SPEED COUNTERCURRENT CHROMATOGRAPHY FOR SEPARATION OF ELATINE FROM DELPHINIUM SHAWURENSE.

Authors:  Yi Yang; Dongyu Gu; Hankui Wu; Haji Akber Aisa; Tianyou Zhang; Yoichiro Ito
Journal:  J Liq Chromatogr Relat Technol       Date:  2008-01-01       Impact factor: 1.312

4.  Countercurrent chromatography with the flow-through centrifuge without rotating seals.

Authors:  Y Ito; R L Bowman
Journal:  Anal Biochem       Date:  1978-04       Impact factor: 3.365

5.  Flat-twisted tubing: novel column design for spiral high-speed counter-current chromatography.

Authors:  Yi Yang; Haji Akber Aisa; Yoichiro Ito
Journal:  J Chromatogr A       Date:  2009-05-18       Impact factor: 4.759

6.  Novel Design for Centrifugal Countercurrent Chromatography: I. Zigzag Toroidal Column.

Authors:  Yi Yang; Haji Akber Aisa; Yoichiro Ito
Journal:  J Liq Chromatogr Relat Technol       Date:  2009-01-01       Impact factor: 1.312

  6 in total
  3 in total

1.  Evaluation on the performance of four different column models mounted on the compact type-I coil planet centrifuge.

Authors:  Yi Yang; Dongyu Gu; Haji Akber Aisa; Yoichiro Ito
Journal:  J Chromatogr A       Date:  2010-10-26       Impact factor: 4.759

2.  Evaluation of the performance of protein separation in figure-8 centrifugal counter-current chromatography.

Authors:  Yi Yang; Dongyu Gu; Haji Akber Aisa; Yoichiro Ito
Journal:  J Chromatogr B Analyt Technol Biomed Life Sci       Date:  2011-10-25       Impact factor: 3.205

3.  Studies on the effect of column angle in figure-8 centrifugal counter-current chromatography.

Authors:  Yi Yang; Dongyu Gu; Haji Akber Aisa; Yoichiro Ito
Journal:  J Chromatogr A       Date:  2010-11-21       Impact factor: 4.759

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.