Literature DB >> 20187184

Determination of the venous output function from MR signal phase: feasibility for quantitative DCE-MRI in human brain.

Claire Foottit1, Greg O Cron, Matthew J Hogan, Thanh Binh Nguyen, Ian Cameron.   

Abstract

For dynamic contrast-enhanced MRI studies in the human brain, it is useful to measure the venous output function (VOF). The purpose of this work was to explore the feasibility of measuring the VOF using the MR signal phase (in absolute units of gadolinium concentration) in the superior sagittal sinus. Phantom experiments were performed to validate the technique for different superior sagittal sinus angles (theta = 0-48 degrees relative to the main magnetic field), different curvatures (straight or radius = 45 mm), and different spatial resolutions (2.2-5.5 mm, to study partial-volume effects). Additionally, the technique was tested on three patients. The phantom experimental results (echo time = 5.5 ms, theta <or= 21 degrees) agreed with theoretical predictions to within 10%. For the patient studies, the measured VOFs had reasonable amplitude and shape characteristics and the patients' superior sagittal sinus angles (<15 degrees) and curvatures (radii approximately 40 mm) were within the range explored with phantoms. Our results suggest that partial-volume contributions to the VOF will be <5% and that the VOF can be evaluated in vivo to within 10% error. In conclusion, it is highly feasible to use MR signal phase to measure the VOF in the superior sagittal sinus for human dynamic contrast-enhanced MRI. (c) 2010 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2010        PMID: 20187184     DOI: 10.1002/mrm.22253

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  14 in total

1.  Utilization of MR angiography in perfusion imaging for identifying arterial input function.

Authors:  Bora Buyuksarac; Mehmed Ozkan
Journal:  MAGMA       Date:  2017-07-25       Impact factor: 2.310

2.  Diagnostic accuracy of dynamic contrast-enhanced MR imaging using a phase-derived vascular input function in the preoperative grading of gliomas.

Authors:  T B Nguyen; G O Cron; J F Mercier; C Foottit; C H Torres; S Chakraborty; J Woulfe; G H Jansen; J M Caudrelier; J Sinclair; M J Hogan; R E Thornhill; I G Cameron
Journal:  AJNR Am J Neuroradiol       Date:  2012-03-22       Impact factor: 3.825

3.  Dynamic susceptibility contrast perfusion MRI using phase-based venous output functions: comparison with pseudo-continuous arterial spin labelling and assessment of contrast agent concentration in large veins.

Authors:  Ronnie Wirestam; Emelie Lind; André Ahlgren; Freddy Ståhlberg; Linda Knutsson
Journal:  MAGMA       Date:  2016-06-13       Impact factor: 2.310

4.  Arterial input functions determined from MR signal magnitude and phase for quantitative dynamic contrast-enhanced MRI in the human pelvis.

Authors:  Greg O Cron; Claire Foottit; Thomas E Yankeelov; Leonard I Avruch; Mark E Schweitzer; Ian Cameron
Journal:  Magn Reson Med       Date:  2011-02-28       Impact factor: 4.668

5.  Phase-based arterial input functions in humans applied to dynamic contrast-enhanced MRI: potential usefulness and limitations.

Authors:  Anders Garpebring; Ronnie Wirestam; Jun Yu; Thomas Asklund; Mikael Karlsson
Journal:  MAGMA       Date:  2011-05-29       Impact factor: 2.310

Review 6.  Magnetic Resonance Imaging of Blood-Brain Barrier permeability in Dementia.

Authors:  Audrey Chagnot; Samuel R Barnes; Axel Montagne
Journal:  Neuroscience       Date:  2021-08-13       Impact factor: 3.708

7.  Comparison of the Diagnostic Accuracy of DSC- and Dynamic Contrast-Enhanced MRI in the Preoperative Grading of Astrocytomas.

Authors:  T B Nguyen; G O Cron; K Perdrizet; K Bezzina; C H Torres; S Chakraborty; J Woulfe; G H Jansen; J Sinclair; R E Thornhill; C Foottit; B Zanette; I G Cameron
Journal:  AJNR Am J Neuroradiol       Date:  2015-07-30       Impact factor: 3.825

8.  Effect of T2* correction on contrast kinetic model analysis using a reference tissue arterial input function at 7 T.

Authors:  Jin Zhang; Melanie Freed; Kerryanne Winters; Sungheon G Kim
Journal:  MAGMA       Date:  2015-08-05       Impact factor: 2.310

9.  A pilot study using dynamic contrast enhanced-MRI as a response biomarker of the radioprotective effect of memantine in patients receiving whole brain radiotherapy.

Authors:  Philip Wong; Ilana R Leppert; David Roberge; Karim Boudam; Paul D Brown; Thierry Muanza; G Bruce Pike; Jeffrey Chankowsky; Catalin Mihalcioiu
Journal:  Oncotarget       Date:  2016-08-09

10.  The use of dynamic tracer concentration in veins for quantitative DCE-MRI kinetic analysis in head and neck.

Authors:  Jing Yuan; Steven Kwok Keung Chow; Qinwei Zhang; David Ka Wai Yeung; Anil T Ahuja; Ann D King
Journal:  PLoS One       Date:  2013-03-20       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.