Literature DB >> 20185133

Quantifying fluid shear stress in a rocking culture dish.

Xiaozhou Zhou1, Dawei Liu, Lidan You, Liyun Wang.   

Abstract

Fluid shear stress (FSS) is an important stimulus for cell functions. Compared with the well established parallel-plate and cone-and-plate systems, a rocking "see-saw" system offers some advantages such as easy operation, low cost, and high throughput. However, the FSS spatiotemporal pattern in the system has not been quantified. In the present study, we developed a lubrication-based model to analyze the FSS distributions in a rocking rectangular culture dish. We identified an important parameter (the critical flip angle) that dictates the overall FSS behaviors and suggested the right conditions to achieving temporally oscillating and spatially relatively uniform FSS. If the maximal rocking angle is kept smaller than the critical flip angle, which is defined as the angle when the fluid free surface intersects the outer edge of the dish bottom, the dish bottom remains covered with a thin layer of culture medium. The spatial variations of the peak FSS within the central 84% and 50% dish bottom are limited to 41% and 17%, respectively. The magnitude of FSS was found to be proportional to the fluid viscosity and the maximal rocking angle, and inversely proportional to the square of the fluid depth-to-length ratio and the rocking period. For a commercial rectangular dish (length of 37.6mm) filled with approximately 2 mL culture medium, the FSS at the center of the dish bottom is expected to be on the order of 0.9 dyn/cm(2) when the dish is rocked +5 degrees at 1 cycle/s. Our analysis suggests that a rocking "see-saw" system, if controlled well, can be used as an alternative method to provide low-magnitude, dynamic FSS to cultured cells. Copyright 2010 Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20185133      PMCID: PMC2866761          DOI: 10.1016/j.jbiomech.2009.12.028

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  18 in total

1.  Fluid shear stress induces differentiation of Flk-1-positive embryonic stem cells into vascular endothelial cells in vitro.

Authors:  Kimiko Yamamoto; Takaaki Sokabe; Tetsuro Watabe; Kohei Miyazono; Jun K Yamashita; Syotaro Obi; Norihiko Ohura; Akiko Matsushita; Akira Kamiya; Joji Ando
Journal:  Am J Physiol Heart Circ Physiol       Date:  2004-12-02       Impact factor: 4.733

2.  Mechanotransduction in bone: osteoblasts are more responsive to fluid forces than mechanical strain.

Authors:  I Owan; D B Burr; C H Turner; J Qiu; Y Tu; J E Onyia; R L Duncan
Journal:  Am J Physiol       Date:  1997-09

3.  Real-time calcium response of cultured bone cells to fluid flow.

Authors:  C T Hung; S R Pollack; T M Reilly; C T Brighton
Journal:  Clin Orthop Relat Res       Date:  1995-04       Impact factor: 4.176

4.  Differential effect of steady versus oscillating flow on bone cells.

Authors:  C R Jacobs; C E Yellowley; B R Davis; Z Zhou; J M Cimbala; H J Donahue
Journal:  J Biomech       Date:  1998-11       Impact factor: 2.712

Review 5.  Flow-mediated endothelial mechanotransduction.

Authors:  P F Davies
Journal:  Physiol Rev       Date:  1995-07       Impact factor: 37.312

6.  A model for the excitation of osteocytes by mechanical loading-induced bone fluid shear stresses.

Authors:  S Weinbaum; S C Cowin; Y Zeng
Journal:  J Biomech       Date:  1994-03       Impact factor: 2.712

7.  Effects of fluid flow on living vascular cells.

Authors:  C F Dewey
Journal:  J Biomech Eng       Date:  1984-02       Impact factor: 2.097

8.  The elongation and orientation of cultured endothelial cells in response to shear stress.

Authors:  M J Levesque; R M Nerem
Journal:  J Biomech Eng       Date:  1985-11       Impact factor: 2.097

9.  Shear stress induced stimulation of mammalian cell metabolism.

Authors:  J A Frangos; L V McIntire; S G Eskin
Journal:  Biotechnol Bioeng       Date:  1988-10-05       Impact factor: 4.530

10.  Expression of interleukin-6 in osteoarthritic chondrocytes and effects of fluid-induced shear on this expression in normal human chondrocytes in vitro.

Authors:  M Mohtai; M K Gupta; B Donlon; B Ellison; J Cooke; G Gibbons; D J Schurman; R L Smith
Journal:  J Orthop Res       Date:  1996-01       Impact factor: 3.494

View more
  18 in total

1.  Charged nanomatrices as efficient platforms for modulating cell adhesion and shape.

Authors:  Jangho Kim; Deok-Ho Kim; Ki Taek Lim; Hoon Seonwoo; Soo Hyun Park; Yang-Rae Kim; Yeonju Kim; Yun-Hoon Choung; Pill-Hoon Choung; Jong Hoon Chung
Journal:  Tissue Eng Part C Methods       Date:  2012-07-16       Impact factor: 3.056

2.  Preclinical models for in vitro mechanical loading of bone-derived cells.

Authors:  Robin Michael Delaine-Smith; Behzad Javaheri; Jennifer Helen Edwards; Marisol Vazquez; Robin Mark Howard Rumney
Journal:  Bonekey Rep       Date:  2015-08-19

3.  A role for the primary cilium in paracrine signaling between mechanically stimulated osteocytes and mesenchymal stem cells.

Authors:  David A Hoey; Daniel J Kelly; Christopher R Jacobs
Journal:  Biochem Biophys Res Commun       Date:  2011-07-23       Impact factor: 3.575

4.  Epigenetic changes during mechanically induced osteogenic lineage commitment.

Authors:  Julia C Chen; Mardonn Chua; Raymond B Bellon; Christopher R Jacobs
Journal:  J Biomech Eng       Date:  2015-01-26       Impact factor: 2.097

5.  See-saw rocking: an in vitro model for mechanotransduction research.

Authors:  R P Tucker; P Henningsson; S L Franklin; D Chen; Y Ventikos; R J Bomphrey; M S Thompson
Journal:  J R Soc Interface       Date:  2014-08-06       Impact factor: 4.118

6.  Fenoldopam Sensitizes Primary Cilia-Mediated Mechanosensing to Promote Osteogenic Intercellular Signaling and Whole Bone Adaptation.

Authors:  Milos Spasic; Michael P Duffy; Christopher R Jacobs
Journal:  J Bone Miner Res       Date:  2022-03-23       Impact factor: 6.390

7.  Non-overlapping functions for Pyk2 and FAK in osteoblasts during fluid shear stress-induced mechanotransduction.

Authors:  Suzanne R L Young; Julia M Hum; Eric Rodenberg; Charles H Turner; Fredrick M Pavalko
Journal:  PLoS One       Date:  2011-01-25       Impact factor: 3.240

8.  Inhibition of T-Type Voltage Sensitive Calcium Channel Reduces Load-Induced OA in Mice and Suppresses the Catabolic Effect of Bone Mechanical Stress on Chondrocytes.

Authors:  Padma P Srinivasan; Ashutosh Parajuli; Christopher Price; Liyun Wang; Randall L Duncan; Catherine B Kirn-Safran
Journal:  PLoS One       Date:  2015-05-26       Impact factor: 3.240

Review 9.  In Vitro Bone Cell Models: Impact of Fluid Shear Stress on Bone Formation.

Authors:  Claudia Wittkowske; Gwendolen C Reilly; Damien Lacroix; Cecile M Perrault
Journal:  Front Bioeng Biotechnol       Date:  2016-11-15

10.  Mechanotransduction activates canonical Wnt/β-catenin signaling to promote lymphatic vascular patterning and the development of lymphatic and lymphovenous valves.

Authors:  Boksik Cha; Xin Geng; Md Riaj Mahamud; Jianxin Fu; Anish Mukherjee; Yeunhee Kim; Eek-Hoon Jho; Tae Hoon Kim; Mark L Kahn; Lijun Xia; J Brandon Dixon; Hong Chen; R Sathish Srinivasan
Journal:  Genes Dev       Date:  2016-06-16       Impact factor: 11.361

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.