Simultaneous assessment of arsenic and selenium in human nail phantoms using a portable x-ray tube and a detector.

Christopher W Roy1, Mihai Raul Gherase, David E B Fleming.   

Abstract

A novel approach to the measurement of arsenic and selenium in nail phantoms is demonstrated. Two-component nail phantoms of 0.7 mm and 1.5 mm thickness were made from a polyester resin-salt mixture and dosed with equal arsenic and selenium concentrations ranging from 0 to 30 microg g(-1). A backing was made to simulate the soft tissue and bone of the great toe. Characteristic x-rays for arsenic and selenium were recorded using a portable x-ray tube and a silicon PiN diode detector. The minimum instrumental detection limits for arsenic and selenium in 0.7 mm solitary nail samples were as follows: 0.510 +/- 0.018 microg g(-1) and 0.519 +/- 0.026 microg g(-1) respectively; for 1.5 mm solitary nail: 0.465 +/- 0.035 microg g(-1) and 0.561 +/- 0.062 microg g(-1); for 0.7 mm nail with backing: 1.522 +/- 0.038 microg g(-1) and 1.401 +/- 0.049 microg g(-1); for 1.5 mm nail with backing: 1.354 +/- 0.054 microg g(-1) and 1.367 +/- 0.068 microg g(-1).

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20182007     DOI: 10.1088/0031-9155/55/6/N02

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  5 in total

1.  Validation of x-ray fluorescence measurements of metals in toenail clippings against inductively coupled plasma mass spectrometry in a Nigerian population<sup/>.

Authors:  Aaron J Specht; Kale Kponee; Kpobari W Nkpaa; Prentiss H Balcom; Jennifer Weuve; Linda H Nie; Marc G Weisskopf
Journal:  Physiol Meas       Date:  2018-08-31       Impact factor: 2.833

2.  Quantification of manganese and mercury in toenail in vivo using portable X-ray fluorescence (XRF).

Authors:  Xinxin Zhang; Aaron J Specht; Marc G Weisskopf; Jennifer Weuve; Linda H Nie
Journal:  Biomarkers       Date:  2017-10-10       Impact factor: 2.658

3.  A novel calibration for L-shell x-ray fluorescence measurements of bone lead concentration using the strontium Kβ/Kαratio.

Authors:  Mihai R Gherase; Blaz Serna; Sarah Kroeker
Journal:  Physiol Meas       Date:  2021-05-14       Impact factor: 2.833

4.  A Dosimetry Study of Portable X-ray Fluorescence in Vivo Metal Measurements.

Authors:  Aaron J Specht; Xinxin Zhang; Benjamin D Goodman; Ed Maher; Marc G Weisskopf; Linda H Nie
Journal:  Health Phys       Date:  2019-05       Impact factor: 2.922

5.  Validation of in vivo toenail measurements of manganese and mercury using a portable X-ray fluorescence device.

Authors:  Jennifer Weuve; Linda H Nie; Marc G Weisskopf; Aaron J Specht; Xinxin Zhang; Anna Young; Vy T Nguyen; David C Christiani; Diana M Ceballos; Joseph G Allen
Journal:  J Expo Sci Environ Epidemiol       Date:  2021-07-01       Impact factor: 5.563

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.