Literature DB >> 20180796

LMA Supreme insertion by novices in manikins and patients.

B W Howes1, N M Wharton, B Gibbison, T M Cook.   

Abstract

The LMA Supreme has been suggested for use in emergency situations by medical personnel with no experience in endotracheal intubation. We evaluated the LMA Supreme when inserted by non-anaesthetists, firstly in a manikin and then in patients. Fifty airway novices inserted a LMA Supreme in a manikin without any complications so we proceeded to the patient phase. Fifty airway novices inserted the LMA Supreme in anaesthetised patients undergoing elective surgery. First time insertion success rate was 86% and overall insertion success rate was 100%. Mechanical ventilation was successful in all cases. Median (IQR [range]) time to establish an airway was 34 s (26-40 [18-145] s). Median (IQR [range]) pharyngeal seal pressure was 23 cmH(2)O (19-28 [13-40] cmH(2)O). There were no important complications. Results are consistent with previous studies of use of the LMA Supreme by airway experts. We conclude that the LMA supreme is suitable for use by airway novices. Further research is needed before it may be recommended for cardiopulmonary resuscitation and emergency airway use.

Entities:  

Mesh:

Year:  2010        PMID: 20180796     DOI: 10.1111/j.1365-2044.2010.06262.x

Source DB:  PubMed          Journal:  Anaesthesia        ISSN: 0003-2409            Impact factor:   6.955


  9 in total

1.  Laryngeal mask airway insertion in adults: comparison between fully deflated and partially inflated technique.

Authors:  Jiwon An; Seo Kyung Shin; Ki Jun Kim
Journal:  Yonsei Med J       Date:  2013-05-01       Impact factor: 2.759

2.  Does a 4 diagram manual enable laypersons to operate the Laryngeal Mask Supreme®? A pilot study in the manikin.

Authors:  Gereon Schälte; Christian Stoppe; Rolf Rossaint; Laura Gilles; Maike Heuser; Steffen Rex; Mark Coburn; Norbert Zoremba; Annette Rieg
Journal:  Scand J Trauma Resusc Emerg Med       Date:  2012-03-27       Impact factor: 2.953

3.  Feasibility of LMA Supreme for airway management in unconscious patients by ALS paramedics.

Authors:  Sami Länkimäki; Seppo Alahuhta; Tom Silfvast; Jouni Kurola
Journal:  Scand J Trauma Resusc Emerg Med       Date:  2015-02-26       Impact factor: 2.953

4.  Layperson mouth-to-mask ventilation using a modified I-gel laryngeal mask after brief onsite instruction: a manikin-based feasibility trial.

Authors:  Gereon Schälte; Lilli-Theresa Bomhard; Rolf Rossaint; Mark Coburn; Christian Stoppe; Norbert Zoremba; Annette Rieg
Journal:  BMJ Open       Date:  2016-05-12       Impact factor: 2.692

5.  Unintentional tracheal extubation during prone position: What is the best rescue airway device?

Authors:  Germano De Cosmo; Elisabetta Congedo
Journal:  J Emerg Trauma Shock       Date:  2017 Jan-Mar

6.  Effect of immobilised cervical spine on oropharyngeal sealing pressure with Ambu AuraGain™ Supraglottic airway: A randomised crossover trial.

Authors:  Duraiyarassu Uthaman; Suman Lata Gupta; Sandeep Kumar Mishra; Satyen Parida; Prasanna Udupi Bidkar; Muthupillai Senthilnathan
Journal:  Indian J Anaesth       Date:  2019-05

7.  An Evaluation of Thyromental Distance-based Method or Weight-based Method in Determining the Size of the Laryngeal Mask Airway Supreme: A Randomized Controlled Study.

Authors:  Meilin Weng; Ming Ding; Yajun Xu; Xijun Yang; Lihong Li; Jing Zhong; Changhong Miao
Journal:  Medicine (Baltimore)       Date:  2016-03       Impact factor: 1.889

8.  Comparison of five 2nd-generation supraglottic airway devices for airway management performed by novice military operators.

Authors:  Tomas Henlin; Michal Sotak; Petr Kovaricek; Tomas Tyll; Lukas Balcarek; Pavel Michalek
Journal:  Biomed Res Int       Date:  2015-10-01       Impact factor: 3.411

9.  Incidence of postoperative sore throat after using a new technique of insertion of a second generation Laryngeal Mask Airway: A randomised controlled trial.

Authors:  Xiaoxiao Li; Xiuli Wang; Ye Zhao; Zhenfei Jiang; Xueli Lv; Xinrui Nie; Tong Li; Xinghe Wang; Lingyun Dai; Su Liu
Journal:  Eur J Anaesthesiol       Date:  2021-03-01       Impact factor: 4.183

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.