Literature DB >> 20180734

Reliability and validity of electrogoniometry measurement of lower extremity movement.

S Bronner1, S Agraharasamakulam, S Ojofeitimi.   

Abstract

OBJECTIVES: To establish the reliability, accuracy and concurrent validity of electrogoniometers for measuring extreme lower extremity movements. STUDY
DESIGN: Reliability, accuracy and validity study.
METHODS: This project employed two experiments. Investigation I determined electrogoniometer accuracy compared to a digital protractor. Investigation II compared electrogoniometers to a criterion measure, motion analysis, in sagittal plane dance movements in 17 dancers. Intraclass correlation coefficients (ICC) and standard error of measurement (SEM) were calculated for hip, knee, and ankle sagittal plane angular displacements.
RESULTS: In Investigation I, electrogoniometer to protractor correlations were high (r > or = 0.998, SEM < or =3.65 degrees ). In Investigation II, instrument and intra-rater reliability correlations were high (r > or = 0.983 and r > or = 0.972, SEM < or = 3.49 degrees and < or =4.48 degrees ), as were concurrent validity correlations (r > or = 0.949, SEM < or =6.80 degrees ) to motion analysis.
CONCLUSIONS: This error may be acceptable for lower extremity studies with extreme movements when motion capture is unavailable.

Entities:  

Mesh:

Year:  2010        PMID: 20180734     DOI: 10.3109/03091900903580512

Source DB:  PubMed          Journal:  J Med Eng Technol        ISSN: 0309-1902


  10 in total

1.  The relationship between lower extremity closed kinetic chain strength & sagittal plane landing kinematics in female athletes.

Authors:  Christopher R Carcia; Ben Kivlan; Jason S Scibek
Journal:  Int J Sports Phys Ther       Date:  2011-03

2.  The influence of heel height on sagittal plane knee kinematics during landing tasks in recreationally active and athletic collegiate females.

Authors:  Kelly M Lindenberg; Christopher R Carcia; Amy L Phelps; Robroy L Martin; Anne M Burrows
Journal:  Int J Sports Phys Ther       Date:  2011-09

3.  Accuracy of an electrogoniometer relative to optical motion tracking for quantifying wrist range of motion.

Authors:  Brian P McHugh; Amy M Morton; Bardiya Akhbari; Janine Molino; Joseph J Crisco
Journal:  J Med Eng Technol       Date:  2020-01-30

4.  Sciatic nerve excursion during neural mobilization with ankle movement using dynamic ultrasound imaging: a cross-sectional study.

Authors:  Ali M Alshami; Tadhi K Alshammari; Mona I AlMuhaish; Tarek M Hegazi; Mahbubunnabi Tamal; Fuad A Abdulla
Journal:  J Ultrasound       Date:  2021-05-25

Review 5.  Robot-aided assessment of lower extremity functions: a review.

Authors:  Serena Maggioni; Alejandro Melendez-Calderon; Edwin van Asseldonk; Verena Klamroth-Marganska; Lars Lünenburger; Robert Riener; Herman van der Kooij
Journal:  J Neuroeng Rehabil       Date:  2016-08-02       Impact factor: 4.262

6.  Effectiveness of adaptive silverware on range of motion of the hand.

Authors:  Susan S McDonald; David Levine; Jim Richards; Lauren Aguilar
Journal:  PeerJ       Date:  2016-02-15       Impact factor: 2.984

7.  Validation of Joint Position Sense of Dorsi-Plantar Flexion of Ankle Measurements Using a Smartphone.

Authors:  Daehee Lee; Seulki Han
Journal:  Healthc Inform Res       Date:  2017-07-31

8.  No difference in knee muscle activation and kinematics during treadmill walking between adolescent girls with and without asymptomatic Generalised Joint Hypermobility.

Authors:  Helene Nikolajsen; Birgit Juul-Kristensen; Peter Fjeldstad Hendriksen; Bente Rona Jensen
Journal:  BMC Musculoskelet Disord       Date:  2021-02-11       Impact factor: 2.362

9.  Integrating the Evidence and Clinical Expertise in the Shared Decision and Graduated Return to Sport Process: A Time Series Case Study after Anterior Cruciate Ligament Rupture and Reconstruction.

Authors:  Daniel Niederer; Jan Wilke; Frieder Krause; Winfried Banzer; Tobias Engeroff
Journal:  J Orthop Case Rep       Date:  2019

10.  Contractile behavior of the gastrocnemius medialis muscle during running in simulated hypogravity.

Authors:  Charlotte Richter; Bjoern Braunstein; Benjamin Staeudle; Julia Attias; Alexander Suess; Tobias Weber; Katya N Mileva; Joern Rittweger; David A Green; Kirsten Albracht
Journal:  NPJ Microgravity       Date:  2021-08-09       Impact factor: 4.415

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.