Literature DB >> 20179725

Robust fitting of [11C]-WAY-100635 PET data.

Francesca Zanderigo1, Robert Todd Ogden, Chung Chang, Stephen Choy, Andrew Wong, Ramin Vaziri Parsey.   

Abstract

Fitting of a positron emission tomography (PET) time-activity curve is typically accomplished according to the least squares (LS) criterion, which is optimal for data having Gaussian distributed errors, but not robust in the presence of outliers. Conversely, quantile regression (QR) provides robust estimates not heavily influenced by outliers, sacrificing a little efficiency relative to LS when no outliers are present. Given these considerations, we hypothesized that QR would improve parameter estimate accuracy as measured by reduced intersubject variance in distribution volume (V(T)) compared with LS in PET modeling. We compare V(T) values after applying QR with those using LS on 49 controls studied with [(11)C]-WAY-100635. QR decreases the standard deviation of the V(T) estimates (relative improvement range: 0.08% to 3.24%), while keeping the within-group average V(T) values almost unchanged. QR variance reduction results in fewer subjects required to maintain the same statistical power in group analysis without additional hardware and/or image registration to correct head motion.

Mesh:

Substances:

Year:  2010        PMID: 20179725      PMCID: PMC2949218          DOI: 10.1038/jcbfm.2010.20

Source DB:  PubMed          Journal:  J Cereb Blood Flow Metab        ISSN: 0271-678X            Impact factor:   6.200


  15 in total

1.  A global optimisation method for robust affine registration of brain images.

Authors:  M Jenkinson; S Smith
Journal:  Med Image Anal       Date:  2001-06       Impact factor: 8.545

2.  Noise reduction in the simplified reference tissue model for neuroreceptor functional imaging.

Authors:  Yanjun Wu; Richard E Carson
Journal:  J Cereb Blood Flow Metab       Date:  2002-12       Impact factor: 6.200

3.  Determination of volume of distribution using likelihood estimation in graphical analysis: elimination of estimation bias.

Authors:  Ramin V Parsey; R Todd Ogden; J John Mann
Journal:  J Cereb Blood Flow Metab       Date:  2003-12       Impact factor: 6.200

4.  Robust fitting for neuroreceptor mapping.

Authors:  Chung Chang; R Todd Ogden
Journal:  Stat Med       Date:  2009-03-15       Impact factor: 2.373

5.  Validation and reproducibility of measurement of 5-HT1A receptor parameters with [carbonyl-11C]WAY-100635 in humans: comparison of arterial and reference tisssue input functions.

Authors:  R V Parsey; M Slifstein; D R Hwang; A Abi-Dargham; N Simpson; O Mawlawi; N N Guo; R Van Heertum; J J Mann; M Laruelle
Journal:  J Cereb Blood Flow Metab       Date:  2000-07       Impact factor: 6.200

6.  Imaging human mesolimbic dopamine transmission with positron emission tomography: I. Accuracy and precision of D(2) receptor parameter measurements in ventral striatum.

Authors:  O Mawlawi; D Martinez; M Slifstein; A Broft; R Chatterjee; D R Hwang; Y Huang; N Simpson; K Ngo; R Van Heertum; M Laruelle
Journal:  J Cereb Blood Flow Metab       Date:  2001-09       Impact factor: 6.200

7.  Graphical analysis of reversible radioligand binding from time-activity measurements applied to [N-11C-methyl]-(-)-cocaine PET studies in human subjects.

Authors:  J Logan; J S Fowler; N D Volkow; A P Wolf; S L Dewey; D J Schlyer; R R MacGregor; R Hitzemann; B Bendriem; S J Gatley
Journal:  J Cereb Blood Flow Metab       Date:  1990-09       Impact factor: 6.200

8.  Quantification of muscarinic cholinergic receptors with [11C]NMPB and positron emission tomography: method development and differentiation of tracer delivery from receptor binding.

Authors:  J K Zubieta; R A Koeppe; G K Mulholland; D E Kuhl; K A Frey
Journal:  J Cereb Blood Flow Metab       Date:  1998-06       Impact factor: 6.200

9.  Reproducibility of repeated measures of carbon-11-raclopride binding in the human brain.

Authors:  N D Volkow; J S Fowler; G J Wang; S L Dewey; D Schlyer; R MacGregor; J Logan; D Alexoff; C Shea; R Hitzemann
Journal:  J Nucl Med       Date:  1993-04       Impact factor: 10.057

Review 10.  Fast robust automated brain extraction.

Authors:  Stephen M Smith
Journal:  Hum Brain Mapp       Date:  2002-11       Impact factor: 5.038

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.