Literature DB >> 20177989

CT perfusion in solid-body tumours. Part I: Technical issues.

G Petralia1, L Preda, G D'Andrea, S Viotti, L Bonello, R De Filippi, M Bellomi.   

Abstract

Functional imaging is becoming increasingly important in both research and clinical diagnostic radiology. Perfusion computed tomography (CTP) is a readily available and widely used tool that allows an objective measurement of tissue perfusion through the mathematical analysis of data obtained from repeated scans performed after administration of contrast agent. Recently, CTP has been increasingly used in the oncological field, being studied as a potential marker of neoplastic angiogenesis, which is one of the main targets of new tumour therapies. The aim of this paper was to provide the theoretical background and practical guidance for accurately performing CTP and interpreting results of examinations in solid-body tumours. CTP could be a valid tool for functional imaging of tumours if the acquisition technique is robust, if image and data analysis is accurate and if interpretation of results is adequately inserted within a clinical context.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20177989     DOI: 10.1007/s11547-010-0519-y

Source DB:  PubMed          Journal:  Radiol Med        ISSN: 0033-8362            Impact factor:   3.469


  38 in total

Review 1.  Perfusion CT: a worthwhile enhancement?

Authors:  K A Miles; M R Griffiths
Journal:  Br J Radiol       Date:  2003-04       Impact factor: 3.039

Review 2.  Clinical application of antiangiogenic therapy: microvessel density, what it does and doesn't tell us.

Authors:  Lynn Hlatky; Philip Hahnfeldt; Judah Folkman
Journal:  J Natl Cancer Inst       Date:  2002-06-19       Impact factor: 13.506

Review 3.  Perfusion CT for the assessment of tumour vascularity: which protocol?

Authors:  K A Miles
Journal:  Br J Radiol       Date:  2003       Impact factor: 3.039

Review 4.  Tumour angiogenesis and its relation to contrast enhancement on computed tomography: a review.

Authors:  K A Miles
Journal:  Eur J Radiol       Date:  1999-06       Impact factor: 3.528

Review 5.  Permeability of continuous capillaries.

Authors:  W P Paaske; P Sejrsen
Journal:  Dan Med Bull       Date:  1989-12

6.  Model-free deconvolution techniques for estimating vascular transport functions.

Authors:  T A Bronikowski; C A Dawson; J H Linehan
Journal:  Int J Biomed Comput       Date:  1983-09

7.  Graphical evaluation of blood-to-brain transfer constants from multiple-time uptake data.

Authors:  C S Patlak; R G Blasberg; J D Fenstermacher
Journal:  J Cereb Blood Flow Metab       Date:  1983-03       Impact factor: 6.200

8.  Quantitative tumor perfusion assessment with multidetector CT: are measurements from two commercial software packages interchangeable?

Authors:  Vicky Goh; Steve Halligan; Clive I Bartram
Journal:  Radiology       Date:  2007-03       Impact factor: 11.105

9.  CT perfusion for the monitoring of neoadjuvant chemotherapy and radiation therapy in rectal carcinoma: initial experience.

Authors:  Massimo Bellomi; Giuseppe Petralia; Angelica Sonzogni; Maria Giulia Zampino; Andrea Rocca
Journal:  Radiology       Date:  2007-08       Impact factor: 11.105

10.  Elevation of circulating big endothelin-1: an independent prognostic factor for tumor recurrence and survival in patients with esophageal squamous cell carcinoma.

Authors:  Wenjie Jiao; Jing Xu; Jinsheng Zheng; Yi Shen; Lesheng Lin; Jian Li
Journal:  BMC Cancer       Date:  2008-11-15       Impact factor: 4.430

View more
  10 in total

1.  Assessment of the nature of residual masses at end of treatment in lymphoma patients using volume perfusion computed tomography.

Authors:  R Syha; L Grünwald; T Horger; D Spira; D Ketelsen; W Vogel; C D Claussen; M Horger
Journal:  Eur Radiol       Date:  2013-12-05       Impact factor: 5.315

Review 2.  Advances in Imaging and Automated Quantification of Malignant Pulmonary Diseases: A State-of-the-Art Review.

Authors:  Bruno Hochhegger; Matheus Zanon; Stephan Altmayer; Gabriel S Pacini; Fernanda Balbinot; Martina Z Francisco; Ruhana Dalla Costa; Guilherme Watte; Marcel Koenigkam Santos; Marcelo C Barros; Diana Penha; Klaus Irion; Edson Marchiori
Journal:  Lung       Date:  2018-10-09       Impact factor: 2.584

3.  Estimation of radiation exposure of 128-slice 4D-perfusion CT for the assessment of tumor vascularity.

Authors:  Dominik Ketelsen; Marius Horger; Markus Buchgeister; Michael Fenchel; Christoph Thomas; Nadine Boehringer; Maximilian Schulze; Ilias Tsiflikas; Claus D Claussen; Martin Heuschmid
Journal:  Korean J Radiol       Date:  2010-08-27       Impact factor: 3.500

4.  [Perfusion computed tomography for diffuse liver diseases].

Authors:  S A Schmidt; M S Juchems
Journal:  Radiologe       Date:  2012-08       Impact factor: 0.635

5.  Iodine concentration as a perfusion surrogate marker in oncology: Further elucidation of the underlying mechanisms using Volume Perfusion CT with 80 kVp.

Authors:  Wolfgang M Thaiss; Ulrike Haberland; Sascha Kaufmann; Daniel Spira; Christoph Thomas; Konstantin Nikolaou; Marius Horger; Alexander W Sauter
Journal:  Eur Radiol       Date:  2015-12-17       Impact factor: 5.315

6.  First-pass perfusion of non-small-cell lung cancer (NSCLC) with 64-detector-row CT: a study of technique repeatability and intra- and interobserver variability.

Authors:  Anna Rita Larici; Lucio Calandriello; Michele Amato; Roberta Silvestri; Annemilia del Ciello; Francesco Molinari; Chiara de Waure; Maria Letizia Vita; Giulia Carnassale; Lorenzo Bonomo
Journal:  Radiol Med       Date:  2013-11-22       Impact factor: 3.469

Review 7.  Role of CT perfusion in monitoring and prediction of response to therapy of head and neck squamous cell carcinoma.

Authors:  Lorenzo Preda; Sonia Francesca Calloni; Marco Elvio Manlio Moscatelli; Maria Cossu Rocca; Massimo Bellomi
Journal:  Biomed Res Int       Date:  2014-07-21       Impact factor: 3.411

8.  Perfusion CT is a valuable diagnostic method for prostate cancer: a prospective study of 94 patients.

Authors:  Elzbieta Luczynska; Pawel Blecharz; Sonia Dyczek; Andrzej Stelmach; Giuseppe Petralia; Massimo Bellomi; Barbara Alicja Jereczek-Fossa; Jerzy Jakubowicz
Journal:  Ecancermedicalscience       Date:  2014-10-27

9.  The Role of Multidetector CT in the Diagnosis of Retroperitoneal Fibrosis: Report of a Case.

Authors:  Hossein Ghanaati; Mehdi Mohammadifar; Mahsa Ghajarzadeh; Kavous Firouznia; Marzieh Motevalli; Amir Hossein Jalali
Journal:  Iran J Radiol       Date:  2012-03-25       Impact factor: 0.212

Review 10.  Functional imaging in lung cancer.

Authors:  S W Harders; S Balyasnikowa; B M Fischer
Journal:  Clin Physiol Funct Imaging       Date:  2013-12-01       Impact factor: 2.273

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.