Literature DB >> 20176439

Solid phase extraction of cadmium on 2-mercaptobenzothiazole loaded on sulfur powder in the medium of ionic liquid 1-butyl-3-methylimidazolium hexafluorophosphate and cold vapor generation-atomic absorption spectrometric determination.

N Pourreza1, K Ghanemi.   

Abstract

A novel solid phase extractor for preconcentration of cadmium at ng L(-1) levels has been developed. Cadmium ions were retained on a column packed with sulfur powder modified with 2-mercaptobenzothiazole (2-MBT) in the medium of 1-butyl-3-methylimidazolium hexafluorophosphate ([bmim](+)PF(6)(-)) ionic liquid. The presence of ionic liquid during modification of sulfur enhanced the retention of cadmium ions on the column. The retained cadmium ions were eluted with 2 mol L(-1) solution of HCl and measured by cold vapor generation-atomic absorption spectrometry (CVG-AAS). By using reaction cell-gas liquid separator (RC-GLS), gaseous cadmium vapors were produced and reached the atomic absorption spectrometer, instantaneously. The influence of different variables on both processes of solid phase extraction and CVG-AAS determination of cadmium ions was investigated. The calibration curve was linear in the range of 10-200 ng L(-1)of cadmium in the initial solution with r=0.9992 (n=8) under optimum conditions. The limit of detection based on three times the standard deviation of the blank (3S(b), n=10) was 4.6 ng L(-1). The relative standard deviation (R.S.D.) of 25 and 150 ng L(-1) of cadmium was 4.1 and 2.2% (n=8), respectively. The procedure was validated by the analysis of a certified reference material (DORM-3), water and fish samples. Copyright 2010 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20176439     DOI: 10.1016/j.jhazmat.2010.01.122

Source DB:  PubMed          Journal:  J Hazard Mater        ISSN: 0304-3894            Impact factor:   10.588


  5 in total

1.  On-line chemical vapour generation of cadmium in the presence of hexacyanochromate(III) for determination by inductively coupled plasma mass spectrometry (ICP-MS).

Authors:  Vedat Yilmaz; Lakeysha Rose; Zikri Arslan; Maria D Little
Journal:  J Anal At Spectrom       Date:  2012-11-01       Impact factor: 4.023

2.  Cyanovanadate(III) complexes as novel additives for efficient generation of volatile cadmium species in complex samples prior to determinations by inductively coupled plasma mass spectrometry (ICP-MS).

Authors:  Vedat Yilmaz; Zikri Arslan; LaKeysha Rose; Maria D Little
Journal:  Talanta       Date:  2013-10-15       Impact factor: 6.057

3.  Efficient generation of volatile cadmium species using Ti(III) and Ti(IV) and application to determination of cadmium by cold vapor generation inductively coupled plasma mass spectrometry (CVG-ICP-MS).

Authors:  Zikri Arslan; Vedat Yilmaz; LaKeysha Rose
Journal:  Microchem J       Date:  2015-11-01       Impact factor: 4.821

4.  Determination of ultra-trace amounts of cadmium by ET-AAS after column preconcentration with a new sorbent of modified MWCNTs.

Authors:  Mohadeseh Madadizadeh; Mohammad Ali Taher; Hamid Ashkenani
Journal:  Environ Monit Assess       Date:  2012-09-01       Impact factor: 2.513

5.  Twist-assisted high sensitivity chiral fiber sensor for Cd2+ concentration detection.

Authors:  Boyao Li; Aoyan Zhang; Lu Peng; Jinghua Sun; Guiyao Zhou
Journal:  iScience       Date:  2022-09-29
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.