Literature DB >> 20173646

Small bowel capsule endoscopy in clinical practice: a multicenter 7-year survey.

Emanuele Rondonotti1, Marco Soncini, Carlo Girelli, Giovanni Ballardini, Guglielmo Bianchi, Sergio Brunati, Laura Centenara, Pietro Cesari, Claudio Cortelezzi, Simona Curioni, Claudio Gozzini, Renzo Gullotta, Marco Lazzaroni, Marta Maino, Giovanna Mandelli, Nicola Mantovani, Elisabetta Morandi, Carlo Pansoni, Walter Piubello, Rocco Putignano, Renzo Schalling, Maria Tatarella, Federica Villa, Pasquale Vitagliano, Antonio Russo, Dario Conte, Enzo Masci, Roberto de Franchis.   

Abstract

BACKGROUND AND AIM: Data about small bowel capsule endoscopy (SBCE) come from studies involving small and highly selected populations. The study aim was to describe extent of use, indications, results, complications, and practical issues of SBCE in clinical practice in a Northern Italian Region (Lombardia).
MATERIALS AND METHODS: Twenty-three out of 29 invited centers fulfilled a specific questionnaire.
RESULTS: Between 2001 and 2008, 2921 procedures were performed and both the number of centers performing SBCE (from 5 to 29) and the number of SBCE (from 7.2 to 69.2 per month) increased steadily. The main indications for SBCE were: obscure gastrointestinal bleeding (OGIB) (43.4%), unexplained anemia (23.9%), suspected Crohn's disease (7.8%) and abdominal pain (5.3%). Overall, SBCE was positive in 50% of cases, negative in 36% and undefined in 14%. The highest diagnostic yields were observed in patients with OGIB (62.5%), polypoid syndromes (74.1%), known (54.8%) or suspected (47.3%) inflammatory bowel disease, while the yields were low in patients examined for chronic diarrhea (27.4%) and abdominal pain (14.9%), 61 patients (2.1%) experienced capsule retention. Thirty-two of them eventually excreted the capsule naturally while endoscopic or surgical retrieval was necessary in 29 (1%) (in two because of obstruction).
CONCLUSION: Over a period of 7 years the use of SBCE in Lombardia increased steadily confirming, in clinical practice, a high diagnostic yield and an acceptable safety profile.

Entities:  

Mesh:

Year:  2010        PMID: 20173646     DOI: 10.1097/MEG.0b013e3283352ced

Source DB:  PubMed          Journal:  Eur J Gastroenterol Hepatol        ISSN: 0954-691X            Impact factor:   2.566


  19 in total

1.  Capsule endoscopy in nonresponsive celiac disease.

Authors:  David S Atlas; Alberto Rubio-Tapia; Carol T Van Dyke; Brian D Lahr; Joseph A Murray
Journal:  Gastrointest Endosc       Date:  2011-08-11       Impact factor: 9.427

Review 2.  Small-bowel capsule endoscopy: a ten-point contemporary review.

Authors:  Anastasios Koulaouzidis; Emanuele Rondonotti; Alexandros Karargyris
Journal:  World J Gastroenterol       Date:  2013-06-28       Impact factor: 5.742

3.  Tracheal aspiration of capsule endoscopes: completing a cases compilation.

Authors:  Anastasios Koulaouzidis; Sarah Douglas; John N Plevris
Journal:  Dig Dis Sci       Date:  2011-10       Impact factor: 3.199

Review 4.  Performance measures for small-bowel endoscopy: A European Society of Gastrointestinal Endoscopy (ESGE) Quality Improvement Initiative.

Authors:  Cristiano Spada; Deirdre McNamara; Edward J Despott; Samuel Adler; Brooks D Cash; Ignacio Fernández-Urién; Hrvoje Ivekovic; Martin Keuchel; Mark McAlindon; Jean-Christophe Saurin; Simon Panter; Cristina Bellisario; Silvia Minozzi; Carlo Senore; Cathy Bennett; Michael Bretthauer; Mario Dinis-Ribeiro; Dirk Domagk; Cesare Hassan; Michal F Kaminski; Colin J Rees; Roland Valori; Raf Bisschops; Matthew D Rutter
Journal:  United European Gastroenterol J       Date:  2019-05-15       Impact factor: 4.623

Review 5.  Capsule retention: prevention, diagnosis and management.

Authors:  Emanuele Rondonotti
Journal:  Ann Transl Med       Date:  2017-05

6.  Outcome in obscure gastrointestinal bleeding after capsule endoscopy.

Authors:  Alex Cañas-Ventura; Lucia Márquez; Xavier Bessa; Josep Maria Dedeu; Marc Puigvehí; Sílvia Delgado-Aros; Ines Ana Ibáñez; Agustin Seoane; Luis Barranco; Felipe Bory; Montserrat Andreu; Begoña González-Suárez
Journal:  World J Gastrointest Endosc       Date:  2013-11-16

7.  Capsule endoscopy: a dangerous but diagnostic tool.

Authors:  Rhatica Srai; Lucinda Tullie; Ashar Wadoodi; Michael Saunders
Journal:  BMJ Case Rep       Date:  2013-09-16

8.  Oral purgative and simethicone before small bowel capsule endoscopy.

Authors:  Bruno Joel Ferreira Rosa; Mara Barbosa; Joana Magalhães; Ana Rebelo; Maria João Moreira; José Cotter
Journal:  World J Gastrointest Endosc       Date:  2013-02-16

9.  Small-Bowel Capsule Endoscopy in Clinical Practice: Has Anything Changed Over 13 Years?

Authors:  Marco Soncini; Carlo Maria Girelli; Roberto de Franchis; Emanuele Rondonotti
Journal:  Dig Dis Sci       Date:  2018-05-16       Impact factor: 3.199

10.  Capsule retentions and incomplete capsule endoscopy examinations: an analysis of 2300 examinations.

Authors:  Charlotte M Höög; Lars-Åke Bark; Juan Arkani; Jacob Gorsetman; Olle Broström; Urban Sjöqvist
Journal:  Gastroenterol Res Pract       Date:  2011-09-29       Impact factor: 2.260

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.