Literature DB >> 20173164

Incidence of and risk factors for pneumothorax and chest tube placement after CT fluoroscopy-guided percutaneous lung biopsy: retrospective analysis of the procedures conducted over a 9-year period.

Takao Hiraki1, Hidefumi Mimura, Hideo Gobara, Kentaro Shibamoto, Daisaku Inoue, Yusuke Matsui, Susumu Kanazawa.   

Abstract

OBJECTIVE: The objective of our study was to retrospectively evaluate the incidence of and the risk factors for pneumothorax and chest tube placement after CT fluoroscopy-guided lung biopsy.
MATERIALS AND METHODS: We analyzed 1,098 CT fluoroscopy-guided lung biopsies conducted with 20-gauge coaxial cutting needles for 1,155 lesions in 1,033 patients. Apart from evaluating the incidence of pneumothorax and chest tube placement, the independent risk factors for pneumothorax and chest tube placement for pneumothorax were determined using multivariate logistic regression analysis.
RESULTS: The overall incidence of pneumothorax was 42.3% (464/1,098). Chest tube placement was required for 11.9% (55/464) of pneumothoraces (5.0% [55/1,098] of the total number of procedures). The significant independent risk factors for pneumothorax were no prior pulmonary surgery (p = 0.001), lesions in the lower lobe (p < 0.001), greater lesion depth (p < 0.001), and a needle trajectory angle of < 45 degrees (p = 0.014); those for chest tube placement for pneumothorax were pulmonary emphysema (p < 0.001) and greater lesion depth (p < 0.001).
CONCLUSION: Pneumothorax frequently occurred and placement of a chest tube was occasionally required for pneumothorax after CT fluoroscopy-guided lung biopsy. To reduce the risk of pneumothorax necessitating chest tube placement, physicians should adopt the shortest needle path to the lesion.

Entities:  

Mesh:

Year:  2010        PMID: 20173164     DOI: 10.2214/AJR.09.3224

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  50 in total

1.  Safer lung biopsy techniques: fewer patients with pneumothorax, fewer chest tube insertions.

Authors:  Kamran Ahrar
Journal:  J Thorac Dis       Date:  2015-10       Impact factor: 2.895

2.  Population-based risk for complications after transthoracic needle lung biopsy of a pulmonary nodule: an analysis of discharge records.

Authors:  Renda Soylemez Wiener; Lisa M Schwartz; Steven Woloshin; H Gilbert Welch
Journal:  Ann Intern Med       Date:  2011-08-02       Impact factor: 25.391

3.  Takao Hiraki's work on interventional radiology.

Authors:  Takao Hiraki
Journal:  World J Radiol       Date:  2010-12-28

4.  CT fluoroscopy-guided preoperative short hook wire placement for small pulmonary lesions: evaluation of safety and identification of risk factors for pneumothorax.

Authors:  Toshihiro Iguchi; Takao Hiraki; Hideo Gobara; Hiroyasu Fujiwara; Yusuke Matsui; Shinichiro Miyoshi; Susumu Kanazawa
Journal:  Eur Radiol       Date:  2015-05-20       Impact factor: 5.315

5.  Efficacy of an opposite position aspiration on resolution of pneumothorax following CT-guided lung biopsy.

Authors:  L-C Zeng; Y Du; H-F Yang; M-G Xie; H-Q Liao; Y-D Zhang; L Li; Q Wang; L Hu; X-X Xu
Journal:  Br J Radiol       Date:  2015-05-12       Impact factor: 3.039

6.  Diagnostic accuracy and safety of CT-guided fine needle aspiration biopsy of pulmonary lesions with non-coaxial technique: a single center experience with 442 biopsies.

Authors:  Çağlar Uzun; Zehra Akkaya; Ebru Düşünceli Atman; Evren Üstüner; Elif Peker; Başak Gülpınar; Atilla Halil Elhan; Koray Ceyhan; Kayhan Çetin Atasoy
Journal:  Diagn Interv Radiol       Date:  2017 Mar-Apr       Impact factor: 2.630

Review 7.  Navigation bronchoscopy for diagnosis and small nodule location.

Authors:  Juan A Muñoz-Largacha; Virginia R Litle; Hiran C Fernando
Journal:  J Thorac Dis       Date:  2017-03       Impact factor: 2.895

8.  Improved targeting accuracy of lung tumor biopsies with scanning-beam digital x-ray tomosynthesis image guidance.

Authors:  Geoff Nelson; Meng Wu; Cameron Hinkel; Ganesh Krishna; Tobias Funk; Jarrett Rosenberg; Rebecca Fahrig
Journal:  Med Phys       Date:  2016-12       Impact factor: 4.071

9.  Patient dose simulations for scanning-beam digital x-ray tomosynthesis of the lungs.

Authors:  Geoff Nelson; Sungwon Yoon; Ganesh Krishna; Brian Wilfley; Rebecca Fahrig
Journal:  Med Phys       Date:  2013-11       Impact factor: 4.071

10.  Complication Rates and Downstream Medical Costs Associated With Invasive Diagnostic Procedures for Lung Abnormalities in the Community Setting.

Authors:  Jinhai Huo; Ying Xu; Tommy Sheu; Robert J Volk; Ya-Chen Tina Shih
Journal:  JAMA Intern Med       Date:  2019-03-01       Impact factor: 21.873