PURPOSE: To compare the diagnostic performance of iterative decomposition of water and fat with echo asymmetry and least-squares estimation (IDEAL) gradient-recalled acquisition in steady-state (GRASS) imaging with a routine magnetic resonance (MR) imaging protocol for evaluating knee cartilage at 3.0 T in patients by using arthroscopy as the reference standard.
MATERIALS AND METHODS: This prospective Health Insurance Portability and Accountability Act-compliant study was performed with a waiver of informed consent from the institutional review board. IDEAL GRASS was added to routine 3.0-T knee MR protocol performed in 95 symptomatic patients (48 males, mean age, 34.5 years; 47 females, mean age, 35.5 years) who underwent subsequent arthroscopic surgery. Radiologists used the routine MR protocol during the first review and IDEAL GRASS during the second to grade each articular surface and to determine the presence of meniscal tears. By using arthroscopy as the reference standard, the sensitivity, specificity, and accuracy of both imaging methods for detecting cartilage lesions and meniscal tears were determined.
RESULTS: By using the z test to compare parameters between methods, the respective sensitivity, specificity, and accuracy for detecting all 192 cartilage lesions were 68.5%, 92.6%, and 84.5% for IDEAL GRASS and 66.1%, 92.9%, and 83.9% for the routine MR protocol. There was no significant difference (P = .34-.83) in parameters between methods for detecting cartilage lesions. The respective parameters for detecting 50 medial meniscal tears were 85.0%, 91.1%, and 87.9% for IDEAL GRASS and 94.0%, 90.0%, and 92.1% for the routine MR protocol. The parameters for detecting 31 lateral meniscal tears were 58.0%, 90.6%, and 80.0% for IDEAL GRASS and 80.1%, 91.4%, and 87.9% for the routine MR protocol. The routine MR protocol had a significantly higher sensitivity for detecting medial meniscal tears (P = .04) and lateral meniscal tears (P = .01) and significantly higher accuracy for detecting lateral meniscal tears (P = .03) than IDEAL GRASS.
CONCLUSION: IDEAL GRASS has similar diagnostic performance as routine MR protocol for evaluating the articular cartilage of the knee in clinical patients at 3.0 T but has significantly lower sensitivity and accuracy for detecting meniscal tears. RSNA, 2010

Entities:  

Mesh:

Year:  2010        PMID: 20173102     DOI: 10.1148/radiol.09091011

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  20 in total

1.  Advanced MRI of articular cartilage.

Authors:  Hillary J Braun; Garry E Gold
Journal:  Imaging Med       Date:  2011-10

Review 2.  The clinical utility and diagnostic performance of MRI for identification and classification of knee osteochondritis dissecans.

Authors:  Carmen E Quatman; Catherine C Quatman-Yates; Laura C Schmitt; Mark V Paterno
Journal:  J Bone Joint Surg Am       Date:  2012-06-06       Impact factor: 5.284

3.  Routine clinical knee MR reports: comparison of diagnostic performance at 1.5 T and 3.0 T for assessment of the articular cartilage.

Authors:  Jacob C Mandell; Jeffrey A Rhodes; Nehal Shah; Glenn C Gaviola; Andreas H Gomoll; Stacy E Smith
Journal:  Skeletal Radiol       Date:  2017-07-17       Impact factor: 2.199

4.  Chronic anterior cruciate ligament tears and associated meniscal and traumatic cartilage lesions: evaluation with morphological sequences at 3.0 T.

Authors:  Marianna Vlychou; Michalis Hantes; Sotirios Michalitsis; Aspasia Tsezou; Ioannis V Fezoulidis; Konstantinos Malizos
Journal:  Skeletal Radiol       Date:  2010-10-27       Impact factor: 2.199

5.  Use magnetic resonance imaging to assess articular cartilage.

Authors:  Yuanyuan Wang; Anita E Wluka; Graeme Jones; Changhai Ding; Flavia M Cicuttini
Journal:  Ther Adv Musculoskelet Dis       Date:  2012-04       Impact factor: 5.346

6.  Radiological Society of North America (RSNA) 2010 Annual Meeting.

Authors:  Jenny T Bencardino
Journal:  Skeletal Radiol       Date:  2011-08       Impact factor: 2.199

7.  Can a single isotropic 3D fast spin echo sequence replace three-plane standard proton density fat-saturated knee MRI at 1.5 T?

Authors:  B Pass; P Robinson; R Hodgson; A J Grainger
Journal:  Br J Radiol       Date:  2015-06-12       Impact factor: 3.039

Review 8.  The clinical utility and diagnostic performance of magnetic resonance imaging for identification of early and advanced knee osteoarthritis: a systematic review.

Authors:  Carmen E Quatman; Carolyn M Hettrich; Laura C Schmitt; Kurt P Spindler
Journal:  Am J Sports Med       Date:  2011-07       Impact factor: 6.202

Review 9.  MRI-based semiquantitative scoring of joint pathology in osteoarthritis.

Authors:  Ali Guermazi; Frank W Roemer; Ida K Haugen; Michel D Crema; Daichi Hayashi
Journal:  Nat Rev Rheumatol       Date:  2013-01-15       Impact factor: 20.543

10.  How reliable is MRI in diagnosing cartilaginous lesions in patients with first and recurrent lateral patellar dislocations?

Authors:  Lars V von Engelhardt; Marthina Raddatz; Bertil Bouillon; Gunter Spahn; Andreas Dàvid; Patrick Haage; Thomas K Lichtinger
Journal:  BMC Musculoskelet Disord       Date:  2010-07-05       Impact factor: 2.362

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.