Literature DB >> 20172124

Increased radial force improves stent deployment in tricuspid but not in bicuspid stenotic native aortic valves.

Rachid Zegdi1, Lucien Lecuyer, Paul Achouh, Blanchard Didier, Antoine Lafont, Christian Latrémouille, Jean-Noël Fabiani.   

Abstract

BACKGROUND: Stent deployment within stenotic native aortic valves has been shown to depend on valve anatomy (presence of bicuspid valve or not). This study investigated the influence of stent stiffness on stent expansion.
METHODS: The study included 88 patients with severe aortic stenosis, and 36 (41%) had bicuspid aortic valves. Two self-expandable stents with different radial force were deployed intraoperatively inside stenotic aortic valves before surgical aortic valve replacement. Patients in group B received a stent stiffer than that in group A. Effect of stent radial force on stent shape and incidence of paraprosthetic gaps was determined.
RESULTS: Noncircular stent deployment was more frequent in bicuspid (81%) than in tricuspid aortic valves (33%; p < 0.0001). Increasing stent radial force significantly improved stent shape in tricuspid valves (circular shape: 60% in group A vs 93% in group B; p = 0.005) but had no significant effect in bicuspid valves (12.5% in group A vs 27% in group B;p = 0.394). Likewise, incidence of paraprosthetic gaps was significantly reduced with the stiff stent in tricuspid valves (64% in group A vs 30% in group B, p = 0.025) but not in bicuspid valves (50% in group A vs 60% in group B; p= 0.722).
CONCLUSIONS: Increased stent radial force had a favorable effect on stent deployment in tricuspid but not in bicuspid valves. In bicuspid valves, stent maldeployment was constant. Leaflet distortion of implanted valved stent might be a concern in this setting. 2010 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2010        PMID: 20172124     DOI: 10.1016/j.athoracsur.2009.12.022

Source DB:  PubMed          Journal:  Ann Thorac Surg        ISSN: 0003-4975            Impact factor:   4.330


  13 in total

Review 1.  Transcatheter aortic valve implantation in bicuspid anatomy.

Authors:  Zhen-Gang Zhao; Hasan Jilaihawi; Yuan Feng; Mao Chen
Journal:  Nat Rev Cardiol       Date:  2014-10-14       Impact factor: 32.419

2.  Hemodynamic Impact of Transcatheter Aortic Valve Deployment Configuration.

Authors:  Eric Sirois; Kewei Li; Joe Calderan; Lisong Ai; Wei Sun
Journal:  J Med Device       Date:  2013-12-05       Impact factor: 0.582

3.  Echocardiographic outcomes of self-expandable CoreValve versus balloon-expandable Edwards SAPIEN XT valves: the comparison of two bioprosthesis implanted in a single centre.

Authors:  Dayimi Kaya; Zulkif Tanriverdi; Huseyin Dursun; Tugce Colluoglu
Journal:  Int J Cardiovasc Imaging       Date:  2016-06-09       Impact factor: 2.357

4.  Simulated transcatheter aortic valve deformation: A parametric study on the impact of leaflet geometry on valve peak stress.

Authors:  Kewei Li; Wei Sun
Journal:  Int J Numer Method Biomed Eng       Date:  2016-07-26       Impact factor: 2.747

5.  Evaluation of the safety and efficacy of transcatheter aortic valve implantation in patients with a severe stenotic bicuspid aortic valve in a Chinese population.

Authors:  Xian-bao Liu; Ju-bo Jiang; Qi-jing Zhou; Zhao-xia Pu; Wei He; Ai-qiang Dong; Yan Feng; Jun Jiang; Yong Sun; Mei-xiang Xiang; Yu-xin He; You-qi Fan; Liang Dong; Jian-an Wang
Journal:  J Zhejiang Univ Sci B       Date:  2015-03       Impact factor: 3.066

6.  Quantification of biomechanical interaction of transcatheter aortic valve stent deployed in porcine and ovine hearts.

Authors:  Joseph Mummert; Eric Sirois; Wei Sun
Journal:  Ann Biomed Eng       Date:  2012-11-17       Impact factor: 3.934

7.  Biomechanical modeling of transcatheter aortic valve replacement in a stenotic bicuspid aortic valve: deployments and paravalvular leakage.

Authors:  Karin Lavon; Gil Marom; Matteo Bianchi; Rotem Halevi; Ashraf Hamdan; Adi Morany; Ehud Raanani; Danny Bluestein; Rami Haj-Ali
Journal:  Med Biol Eng Comput       Date:  2019-08-01       Impact factor: 2.602

8.  Total ellipse of the heart valve: the impact of eccentric stent distortion on the regional dynamic deformation of pericardial tissue leaflets of a transcatheter aortic valve replacement.

Authors:  Paul S Gunning; Neelakantan Saikrishnan; Ajit P Yoganathan; Laoise M McNamara
Journal:  J R Soc Interface       Date:  2015-12-06       Impact factor: 4.118

Review 9.  Role of computed tomography imaging for transcatheter valvular repair/insertion.

Authors:  See Hooi Ewe; Robert J Klautz; Martin J Schalij; Victoria Delgado
Journal:  Int J Cardiovasc Imaging       Date:  2011-02-26       Impact factor: 2.357

10.  Percutaneous aortic valve implantation in bicuspid aortic valve: A case report.

Authors:  Seyed Ebrahim Kassaian; Faramarz Fallahi; Mahmood Shirzad; Mohammad Sahebjam; Mojtaba Salarifar
Journal:  ARYA Atheroscler       Date:  2015-05
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.