Literature DB >> 20161283

In vivo wireless ethanol vapor detection in the Wistar rat.

C Parks Cheney1, B Srijanto, D L Hedden, A Gehl, T L Ferrell, J Schultz, E A Engleman, W J McBride, S O'Connor.   

Abstract

Traditional alcohol studies measure blood alcohol concentration to elucidate the biomedical factors that contribute to alcohol abuse and alcoholism. These measurements require large and expensive equipment, are labor intensive, and are disruptive to the subject. To alleviate these problems, we have developed an implantable, wireless biosensor that is capable of measuring alcohol levels for up to six weeks. Ethanol levels were measured in vivo in the interstitial fluid of a Wistar rat after administering 1 g/kg and 2 g/kg ethanol by intraperitoneal (IP) injection. The data were transmitted wirelessly using a biosensor selective for alcohol detection. A low-power piezoresistive microcantilever sensor array was used with a polymer coating suitable for measuring ethanol concentrations at 100% humidity over several hours. A hydrophobic, vapor permeable nanopore membrane was used to screen liquid and ions while allowing vapor to pass to the sensor from the subcutaneous interstitial fluid.

Entities:  

Year:  2009        PMID: 20161283      PMCID: PMC2703487          DOI: 10.1016/j.snb.2009.01.052

Source DB:  PubMed          Journal:  Sens Actuators B Chem        ISSN: 0925-4005            Impact factor:   7.460


  4 in total

1.  Environmental sensors based on micromachined cantilevers with integrated read-out

Authors: 
Journal:  Ultramicroscopy       Date:  2000-02       Impact factor: 2.689

2.  Novel electrical detection of label-free disease marker proteins using piezoresistive self-sensing micro-cantilevers.

Authors:  Kyung Wook Wee; Ghi Yuun Kang; Jaebum Park; Ji Yoon Kang; Dae Sung Yoon; Jung Ho Park; Tae Song Kim
Journal:  Biosens Bioelectron       Date:  2005-04-15       Impact factor: 10.618

3.  Implantation of a refillable glucose monitoring-telemetry device.

Authors:  P Atanasov; S Yang; C Salehi; A L Ghindilis; E Wilkins; D Schade
Journal:  Biosens Bioelectron       Date:  1997       Impact factor: 10.618

4.  In vivo time-course changes in ethanol levels sampled with subcutaneous microdialysis.

Authors:  Eric A Engleman; Cynthia M Ingraham; Kelle M Franklin; Carrie M Keith; Joseph A McClaren; Jonathan A Schultz; Sandra L Morzorati; Sean O'Connor; Richard J Thielen; James M Murphy; William J McBride
Journal:  Alcohol Clin Exp Res       Date:  2008-01-22       Impact factor: 3.455

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.