Literature DB >> 10741646

Environmental sensors based on micromachined cantilevers with integrated read-out

.   

Abstract

An AFM probe with integrated piezoresistive read-out has been developed and applied as a cantilever-based environmental sensor. The probe has a built-in reference cantilever, which makes it possible to subtract background drift directly in the measurement. Moreover, the integrated read-out facilitates measurements in liquid. The probe has been successfully implemented in gaseous as well as in liquid experiments. For example, the probe has been used as an accurate and minute thermal sensor and as a humidity sensor. In liquid, the probe has been used to detect the presence of alcohol in water.

Entities:  

Year:  2000        PMID: 10741646     DOI: 10.1016/s0304-3991(99)00148-5

Source DB:  PubMed          Journal:  Ultramicroscopy        ISSN: 0304-3991            Impact factor:   2.689


  13 in total

1.  In vivo wireless ethanol vapor detection in the Wistar rat.

Authors:  C Parks Cheney; B Srijanto; D L Hedden; A Gehl; T L Ferrell; J Schultz; E A Engleman; W J McBride; S O'Connor
Journal:  Sens Actuators B Chem       Date:  2009-04-24       Impact factor: 7.460

2.  Review: Semiconductor Piezoresistance for Microsystems.

Authors:  A Alvin Barlian; Woo-Tae Park; Joseph R Mallon; Ali J Rastegar; Beth L Pruitt
Journal:  Proc IEEE Inst Electr Electron Eng       Date:  2009       Impact factor: 10.961

3.  Analysis of detection enhancement using microcantilevers with long-slit-based sensors.

Authors:  Abdul-Rahim A Khaled; Kambiz Vafai
Journal:  Sensors (Basel)       Date:  2013-01-07       Impact factor: 3.576

4.  Monolithic composite “pressure + acceleration + temperature + infrared” sensor using a versatile single-sided “SiN/Poly-Si/Al” process-module.

Authors:  Zao Ni; Chen Yang; Dehui Xu; Hong Zhou; Wei Zhou; Tie Li; Bin Xiong; Xinxin Li
Journal:  Sensors (Basel)       Date:  2013-01-16       Impact factor: 3.576

Review 5.  SU-8 Cantilevers for Bio/chemical Sensing; Fabrication, Characterisation and Development of Novel Read-out Methods.

Authors:  Maria Nordström; Stephan Keller; Michael Lillemose; Alicia Johansson; Søren Dohn; Daniel Haefliger; Gabriela Blagoi; Mogens Havsteen-Jakobsen; Anja Boisen
Journal:  Sensors (Basel)       Date:  2008-03-10       Impact factor: 3.576

6.  An analytical model of joule heating in piezoresistive microcantilevers.

Authors:  Mohd Zahid Ansari; Chongdu Cho
Journal:  Sensors (Basel)       Date:  2010-11-01       Impact factor: 3.576

7.  Analysis of deflection enhancement using epsilon assembly microcantilevers based sensors.

Authors:  Abdul-Rahim A Khaled; Kambiz Vafai
Journal:  Sensors (Basel)       Date:  2011-09-28       Impact factor: 3.576

8.  A self-sensing piezoelectric microcantilever biosensor for detection of ultrasmall adsorbed masses: theory and experiments.

Authors:  Samira Faegh; Nader Jalili; Srinivas Sridhar
Journal:  Sensors (Basel)       Date:  2013-05-10       Impact factor: 3.576

Review 9.  Atomic force microscopy as a tool applied to nano/biosensors.

Authors:  Clarice Steffens; Fabio L Leite; Carolina C Bueno; Alexandra Manzoli; Paulo Sergio De Paula Herrmann
Journal:  Sensors (Basel)       Date:  2012-06-14       Impact factor: 3.576

10.  Electrical detection of C-reactive protein using a single free-standing, thermally controlled piezoresistive microcantilever for highly reproducible and accurate measurements.

Authors:  Yi-Kuang Yen; Yu-Cheng Lai; Wei-Ting Hong; Yotsapoom Pheanpanitporn; Chuin-Shan Chen; Long-Sun Huang
Journal:  Sensors (Basel)       Date:  2013-07-29       Impact factor: 3.576

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.