Literature DB >> 20157664

Bond strength of poly(methyl methacrylate) denture base material to cast titanium and cobalt-chromium alloy.

Yasuhiro Matsuda1, Hiroaki Yanagida, Takako Ide, Hideo Matsumura, Naomi Tanoue.   

Abstract

PURPOSE: The shear bond strength of an auto-polymerizing poly(methyl methacrylate) denture base resin material to cast titanium and cobalt-chromium alloy treated with six conditioning methods was investigated.
MATERIALS AND METHODS: Disk specimens (10 mm in diameter and 2.5 mm in thickness) were cast from pure titanium and cobalt-chromium alloy. The specimens were wet ground to a final surface finish of 600 grit, air dried, and treated with the following bonding systems: 1) air abraded with 50-70-microm-grain alumina (SAN); 2) air abraded with 50-70-microm-grain alumina + conditioned with Alloy Primer (ALP); 3) air abraded with 50-70-microm-grain alumina + conditioned with AZ Primer (AZP); 4) air abraded with 50-70-microm-grain alumina + conditioned with Estenia Opaque Primer (EOP); 5) air abraded with 50-70-microm-grain alumina + conditioned with Metal Link Primer (MLP), and 6) treated with ROCATEC system (ROC). A denture base material (Palapress Vario) was then applied to each metal specimen. Shear bond strengths were determined before and after 10,000 thermocycles.
RESULTS: The strengths decreased after thermocycling in all combinations. Among the treatment methods assessed, groups 2 and 4 showed significantly (p < 0.05) enhanced shear bond strengths for both metals. In group 4, the strength in MPa (n = 7) after thermocycling for cobalt-chromium alloy was 38.3, which was statistically (p < 0.05) higher than that for cast titanium (34.7).
CONCLUSION: Air abrasion followed by the application of two primers containing a hydrophobic phosphate monomer (MDP) effectively improved the strength of the bond of denture base material to cast titanium and cobalt-chromium alloy.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20157664     DOI: 10.3290/j.jad.a17550

Source DB:  PubMed          Journal:  J Adhes Dent        ISSN: 1461-5185            Impact factor:   2.359


  5 in total

1.  Investigation into the effect of use of metal primer on adhesion of heat cure acrylic resin to cast titanium: an in vitro study.

Authors:  Sudipto Podder; Preeti Goel; Sunil Kar; Jayanta Bhattacharyya
Journal:  J Indian Prosthodont Soc       Date:  2013-10-05

2.  Retention strength between veneering resin composites and laser-sintered cobalt-chromium alloy.

Authors:  Kohji Kamada; Yohsuke Taira; Tadateru Sumi; Takashi Sawase
Journal:  Odontology       Date:  2016-06-20       Impact factor: 2.634

3.  Factors affecting the bond strength of denture base and reline acrylic resins to base metal materials.

Authors:  Naomi Tanoue; Yasuhiro Matsuda; Hiroaki Yanagida; Hideo Matsumura; Takashi Sawase
Journal:  J Appl Oral Sci       Date:  2013 Jul-Aug       Impact factor: 2.698

4.  The Effect of Artificial Aging on The Bond Strength of Heat-activated Acrylic Resin to Surface-treated Nickel-chromium-beryllium Alloy.

Authors:  Youssef S Al Jabbari; Spiros Zinelis; Sara M Al Taweel; William W Nagy
Journal:  Open Dent J       Date:  2016-04-30

5.  Comparison of the effectiveness of Tokuyama and GC II metal primer on the bond strength of acrylic resins to Ti-6Al-7Nb.

Authors:  Sunit Kumar Jurel; Niraj Mishra; Pooran Chand; Himanshi Aggarwal; Raghuwar Dayal Singh; Balendra Pratap Singh
Journal:  Natl J Maxillofac Surg       Date:  2017 Jul-Dec