Literature DB >> 20155985

Enhanced tumor cell isolation by a biomimetic combination of E-selectin and anti-EpCAM: implications for the effective separation of circulating tumor cells (CTCs).

Ja Hye Myung1, Cari A Launiere, David T Eddington, Seungpyo Hong.   

Abstract

The selective detection of circulating tumor cells (CTCs) is of significant clinical importance for the clinical diagnosis and prognosis of cancer metastasis. However, largely because of the extremely low number of CTCs (as low as 1 in 10(9) hematologic cells) in the blood of patients, effective detection and separation of the rare cells remain a tremendous challenge. Cell rolling is known to play a key role in physiological processes such as the recruitment of leukocytes to sites of inflammation and selectin-mediated CTC metastasis. Furthermore, because CTCs typically express the epithelial-cell adhesion molecule (EpCAM) on the surface whereas normal hematologic cells do not, substrates with immobilized antibody against EpCAM may specifically interact with CTCs. In this article, we created biomimetic surfaces functionalized with P- and E-selectin and anti-EpCAM that induce different responses in HL-60 (used as a model of leukocytes in this study) and MCF-7 (a model of CTCs) cells. HL-60 and MCF-7 cells showed different degrees of interaction with P-/E-selectin and anti-EpCAM at a shear stress of 0.32 dyn/cm(2). HL-60 cells exhibited rolling on P-selectin-immobilized substrates at a velocity of 2.26 +/- 0.28 microm/s whereas MCF-7 cells had no interaction with the surface. Both cell lines, however, had interactions with E-selectin, and the rolling velocity of MCF-7 cells (4.24 +/- 0.31 microm/s) was faster than that of HL-60 cells (2.12 +/- 0.15 microm/s). However, only MCF-7 cells interacted with anti-EpCAM-coated surfaces, forming stationary binding under flow. More importantly, the combination of the rolling (E-selectin) and stationary binding (anti-EpCAM) resulted in substantially enhanced separation capacity and capture efficiency (more than 3-fold enhancement), as compared to a surface functionalized solely with anti-EpCAM that has been commonly used for CTC capture. Our results indicate that cell-specific detection and separation may be achieved through mimicking the biological processes of combined dynamic cell rolling and stationary binding, which will likely lead to a CTC detection device with significantly enhanced specificity and sensitivity without a complex fabrication process.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20155985      PMCID: PMC2877147          DOI: 10.1021/la904678p

Source DB:  PubMed          Journal:  Langmuir        ISSN: 0743-7463            Impact factor:   3.882


  43 in total

1.  Cell separation mediated by differential rolling adhesion.

Authors:  A W Greenberg; D A Hammer
Journal:  Biotechnol Bioeng       Date:  2001-04-20       Impact factor: 4.530

2.  Chaotic mixer for microchannels.

Authors:  Abraham D Stroock; Stephan K W Dertinger; Armand Ajdari; Igor Mezic; Howard A Stone; George M Whitesides
Journal:  Science       Date:  2002-01-25       Impact factor: 47.728

3.  Relationship between the velocity of rolling granulocytes and that of the blood flow in venules.

Authors:  A Atherton; G V Born
Journal:  J Physiol       Date:  1973-08       Impact factor: 5.182

4.  Antigen-independent binding of rat immunoglobulins in a radioimmunoassay. Solutions to an unusual background problem.

Authors:  R Nilsson; H O Sjögren
Journal:  J Immunol Methods       Date:  1984-01-20       Impact factor: 2.303

Review 5.  Lymphangiogenesis and tumor metastasis: myth or reality?

Authors:  M S Pepper
Journal:  Clin Cancer Res       Date:  2001-03       Impact factor: 12.531

Review 6.  Control of growth and normal differentiation in leukemic cells: regulation of the developmental program and restoration of the normal phenotype in myeloid leukemia.

Authors:  L Sachs
Journal:  J Cell Physiol Suppl       Date:  1982

7.  A rare-cell detector for cancer.

Authors:  Robert T Krivacic; Andras Ladanyi; Douglas N Curry; H B Hsieh; Peter Kuhn; Danielle E Bergsrud; Jane F Kepros; Todd Barbera; Michael Y Ho; Lan Bo Chen; Richard A Lerner; Richard H Bruce
Journal:  Proc Natl Acad Sci U S A       Date:  2004-07-12       Impact factor: 11.205

8.  Circulating tumor cells, disease progression, and survival in metastatic breast cancer.

Authors:  Massimo Cristofanilli; G Thomas Budd; Matthew J Ellis; Alison Stopeck; Jeri Matera; M Craig Miller; James M Reuben; Gerald V Doyle; W Jeffrey Allard; Leon W M M Terstappen; Daniel F Hayes
Journal:  N Engl J Med       Date:  2004-08-19       Impact factor: 91.245

9.  Rolling of human bone-metastatic prostate tumor cells on human bone marrow endothelium under shear flow is mediated by E-selectin.

Authors:  Charles J Dimitroff; Mirna Lechpammer; Denise Long-Woodward; Jeffery L Kutok
Journal:  Cancer Res       Date:  2004-08-01       Impact factor: 12.701

10.  Discordant expression of selectin ligands and sialyl Lewis x-related epitopes on murine myeloid cells.

Authors:  Marcin M A Kobzdej; Anne Leppänen; Vishwanath Ramachandran; Richard D Cummings; Rodger P McEver
Journal:  Blood       Date:  2002-08-29       Impact factor: 22.113

View more
  29 in total

1.  Antibody-functionalized fluid-permeable surfaces for rolling cell capture at high flow rates.

Authors:  Sukant Mittal; Ian Y Wong; William M Deen; Mehmet Toner
Journal:  Biophys J       Date:  2012-02-21       Impact factor: 4.033

2.  Dendrimer-mediated multivalent binding for the enhanced capture of tumor cells.

Authors:  Ja Hye Myung; Khyati A Gajjar; Jelena Saric; David T Eddington; Seungpyo Hong
Journal:  Angew Chem Int Ed Engl       Date:  2011-10-19       Impact factor: 15.336

3.  Computational design optimization for microfluidic magnetophoresis.

Authors:  Brian D Plouffe; Laura H Lewis; Shashi K Murthy
Journal:  Biomicrofluidics       Date:  2011-03-30       Impact factor: 2.800

4.  Identification of novel molecular markers for detection of gastric cancer cells in the peripheral blood circulation using genome-wide microarray analysis.

Authors:  Nobuyuki Matsumura; Hitoshi Zembutsu; Koji Yamaguchi; Kazuaki Sasaki; Tetsuhiro Tsuruma; Toshihiko Nishidate; Ryuichi Denno; Koichi Hirata
Journal:  Exp Ther Med       Date:  2011-04-08       Impact factor: 2.447

Review 5.  Recent advances in nanotechnology-based detection and separation of circulating tumor cells.

Authors:  Ja Hye Myung; Kevin A Tam; Sin-jung Park; Ashley Cha; Seungpyo Hong
Journal:  Wiley Interdiscip Rev Nanomed Nanobiotechnol       Date:  2015-08-21

6.  Direct measurements on CD24-mediated rolling of human breast cancer MCF-7 cells on E-selectin.

Authors:  Ja Hye Myung; Khyati A Gajjar; Ryan M Pearson; Cari A Launiere; David T Eddington; Seungpyo Hong
Journal:  Anal Chem       Date:  2011-01-05       Impact factor: 6.986

7.  A microfluidic cell concentrator.

Authors:  Jay Warrick; Ben Casavant; Megan Frisk; David Beebe
Journal:  Anal Chem       Date:  2010-10-01       Impact factor: 6.986

8.  Isolation of viable cancer cells in antibody-functionalized microfluidic devices.

Authors:  Xiangjun Zheng; Linan Jiang; Joyce Schroeder; Alison Stopeck; Yitshak Zohar
Journal:  Biomicrofluidics       Date:  2014-04-30       Impact factor: 2.800

9.  Multivalent Binding and Biomimetic Cell Rolling Improves the Sensitivity and Specificity of Circulating Tumor Cell Capture.

Authors:  Ja Hye Myung; Michael J Eblan; Joseph M Caster; Sin-Jung Park; Michael J Poellmann; Kyle Wang; Kevin A Tam; Seth M Miller; Colette Shen; Ronald C Chen; Tian Zhang; Joel E Tepper; Bhishamjit S Chera; Andrew Z Wang; Seungpyo Hong
Journal:  Clin Cancer Res       Date:  2018-03-15       Impact factor: 12.531

Review 10.  Microfluidics and cancer: are we there yet?

Authors:  Zhuo Zhang; Sunitha Nagrath
Journal:  Biomed Microdevices       Date:  2013-08       Impact factor: 2.838

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.