Literature DB >> 20152389

Temperature-controlled ionic liquid-liquid-phase microextraction for the pre-concentration of lead from environmental samples prior to flame atomic absorption spectrometry.

Huahua Bai1, Qingxiang Zhou, Guohong Xie, Junping Xiao.   

Abstract

Hydrophobic ionic liquid could be dispersed into infinite droplets under driving of high temperature, and then they can aggregate as big droplets at low temperature. Based on this phenomenon a new liquid-phase microextraction for the pre-concentration of lead was developed. In this experiment, lead was transferred into its complex using dithizone as chelating agent, and then entered into the infinite ionic liquid drops at high temperature. After cooled with ice-water bath and centrifuged, lead complex was enriched in the ionic liquid droplets. Important parameters affected the extraction efficiency had been investigated including the pH of working solution, amount of chelating agent, volume of ionic liquid, extraction time, centrifugation time, and temperature, etc. The results showed that the usually coexisting ions containing in water samples had no obvious negative effect on the recovery of lead. The experimental results indicated that the proposed method had a good linearity (R=0.9951) from 10 ng mL(-1) to 200 ng mL(-1). The precision was 4.4% (RSD, n=6) and the detection limit was 9.5 ng mL(-1). This novel method was validated by determination of lead in four real environmental samples for the applicability and the results showed that the proposed method was excellent for the future use and the recoveries were in the range of 94.8-104.1%. Copyright (c) 2009 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 20152389     DOI: 10.1016/j.talanta.2009.09.059

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  10 in total

1.  Estimation of lead in biological samples of oral cancer patients chewing smokeless tobacco products by ionic liquid-based microextraction in a single syringe system.

Authors:  Sadaf S Arain; Tasneem G Kazi; Asma J Arain; Hassan I Afridi; Muhammad B Arain; Kapil D Brahman; Abdul H Panhwar; Mariam S Arain
Journal:  Environ Sci Pollut Res Int       Date:  2015-04-23       Impact factor: 4.223

2.  Preconcentration and determination of lead and cadmium levels in blood samples of adolescent workers consuming smokeless tobacco products in Pakistan.

Authors:  Sadaf Sadia Arain; Tasneem Gul Kazi; Hassan Imran Afridi; Kapil Dev Brahman; Sumaira Khan; Abdul Haleem Panhwar; Muhammad Afzal Kamboh; Jamil R Memon
Journal:  Environ Monit Assess       Date:  2015-05-01       Impact factor: 2.513

3.  Vortex assisted solid-phase extraction of lead(II) using orthorhombic nanosized Bi2WO6 as a sorbent.

Authors:  Neda Baghban; Erkan Yilmaz; Mustafa Soylak
Journal:  Mikrochim Acta       Date:  2017-12-07       Impact factor: 5.833

4.  Ultrasound-assisted ionic liquid-based microextraction combined with least squares support vector machines regression for the simultaneous determination of aluminum, gallium, and indium in water and coal samples.

Authors:  Jahan B Ghasemi; Ehsan Zolfonoun
Journal:  Environ Monit Assess       Date:  2011-07-27       Impact factor: 2.513

5.  2-Nitroso-1-naphthol as a selective reagent for preconcentration of cobalt by vortex assisted combined with solidification of organic droplet and its determination by flame atomic absorption spectrometry.

Authors:  Mahmoud Chamsaz; Mohammad Eftekhari; Ali Eftekhari; Ali Yekkebashi
Journal:  Environ Monit Assess       Date:  2013-05-07       Impact factor: 2.513

6.  Synthesis of molecularly imprinted nanoparticles for selective exposure assessment of permethrin: optimization by response surface methodology.

Authors:  Omid Reza Heravizadeh; Monireh Khadem; Ramin Nabizadeh; Seyed Jamaleddin Shahtaheri
Journal:  J Environ Health Sci Eng       Date:  2019-03-06

7.  Vortex-assisted ionic liquid microextraction coupled to flame atomic absorption spectrometry for determination of trace levels of cadmium in real samples.

Authors:  Mahmoud Chamsaz; Atefe Atarodi; Mohammad Eftekhari; Saeid Asadpour; Mina Adibi
Journal:  J Adv Res       Date:  2012-01-13       Impact factor: 10.479

8.  Determination of Ferulic Acid in Angelica sinensis by Temperature-Controlled Hydrophobic Ionic Liquids-Based Ultrasound/Heating-Assisted Extraction Coupled with High Performance Liquid Chromatography.

Authors:  Hongwei Wu; Qianqian Huang; Shujun Chao; Jie Yu; Shengrui Xu; Feng Wang; Xuefang Shang; Yan Zhu
Journal:  Molecules       Date:  2020-07-24       Impact factor: 4.411

Review 9.  Engineering encapsulated ionic liquids for next-generation applications.

Authors:  Jieming Yan; Filippo Mangolini
Journal:  RSC Adv       Date:  2021-11-12       Impact factor: 4.036

Review 10.  Determination of Heavy Metal Ions and Organic Pollutants in Water Samples Using Ionic Liquids and Ionic Liquid-Modified Sorbents.

Authors:  Minglei Tian; Luwei Fang; Xuemin Yan; Wei Xiao; Kyung Ho Row
Journal:  J Anal Methods Chem       Date:  2019-10-31       Impact factor: 2.193

  10 in total