Literature DB >> 20152274

Optimal reconstructed section thickness for the detection of liver lesions with multidetector CT.

G Soo1, K K Lau, T Yik, P Kutschera.   

Abstract

AIM: To evaluate the impact of different reconstructed section thicknesses on liver lesion detection using multidetector computed tomography (CT).
METHODS: Fifty-three patients were examined using a 16-section CT machine with axial reconstructions provided at 2.5, 5, 7.5, and 10mm section thicknesses. Images of different reconstructed section thicknesses from different patients were presented in random order to three independent, blinded radiologists for review at multiple sessions. All images were then reviewed by three radiologists in a common session. Consensus was reached following review of the previous interpretation results and results of follow-up imaging regarding the number of true liver lesions (n=101) for comparison.
RESULTS: Mean detection rates were as follows: 93/101 lesions detected with the 2.5mm section thickness, 98/101 lesions detected at the 5mm section thickness, 78/101 lesions detected at the 7.5mm section thickness, and 54/101 lesions detected at the 10mm section thickness. Lesions missed at the 2.5mm section thickness were due to masking by image noise. There was particular difficulty detecting subcapsular lesions and lesions adjacent to fissures or the gall bladder at the 7.5mm and 10mm section thicknesses.
CONCLUSION: The optimal reconstructed section thickness for lesion detection in the liver was 5mm. Copyright (c) 2010 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2009        PMID: 20152274     DOI: 10.1016/j.crad.2009.10.009

Source DB:  PubMed          Journal:  Clin Radiol        ISSN: 0009-9260            Impact factor:   2.350


  3 in total

1.  Comparison of thick- and thin-slice images in thoracoabdominal trauma CT: a retrospective analysis.

Authors:  Leon Guchlerner; Julian Lukas Wichmann; Patricia Tischendorf; Moritz Albrecht; Thomas Josef Vogl; Sebastian Wutzler; Hanns Ackermann; Katrin Eichler; Claudia Frellesen
Journal:  Eur J Trauma Emerg Surg       Date:  2018-09-28       Impact factor: 3.693

2.  Optimal slice thickness for object detection with longitudinal partial volume effects in computed tomography.

Authors:  Pascal Monnin; Nicolas Sfameni; Achille Gianoli; Sandrine Ding
Journal:  J Appl Clin Med Phys       Date:  2016-11-23       Impact factor: 2.102

3.  Feasibility of thin-slice abdominal CT in overweight patients using a vendor neutral image-based denoising algorithm: Assessment of image noise, contrast, and quality.

Authors:  Akio Tamura; Manabu Nakayama; Yoshitaka Ota; Masayoshi Kamata; Yasuyuki Hirota; Misato Sone; Makoto Hamano; Ryoichi Tanaka; Kunihiro Yoshioka
Journal:  PLoS One       Date:  2019-12-17       Impact factor: 3.240

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.