PURPOSE: The aim of this study was (a) to compare arterial enhancement in simultaneously acquired high- and low-kilovoltage images; and (b) to determine whether low tube-voltage imaging would permit PE evaluation on routine chest CT studies or CTPA studies performed with a low volume of contrast media.
MATERIALS AND METHODS: We compared 20 CTPA studies (CTPA group), 20 routine thoracic CT studies (RT group) and 10 CTPA studies performed with reduced volume of contrast media (RC group). HU values were measured in all groups at 80 kVp and 140 kVp images in multiple pulmonary arterial segments bilaterally. The diagnostic quality of the central and peripheral vascular enhancement and the image noise were evaluated at both energies using a five-point scale.
RESULTS: For all patients, the mean CT attenuation values were greater at 80 kVp than 140 kVp images (p<0.001). At 80 kVp, CTPA group attenuation values were greater than RT group (p=0.03) with a similar trend at 140 kVp (p=0.08). At both 140 kVp and 80 kVp, CTPA group attenuation values were greater than RC group (p=0.02 and p=0.03, respectively). Qualitative analysis showed that at 140 kVp CTPA studies had better global image quality scores than RT (p=0.003) and RC (p=0.001) groups. However, at 80 kVp, there was no significant difference of global image quality between CTPA and the other groups (p=0.4 and p=0.5, respectively). Although measurable image noise was greater at 80 kVp than 140 kVp (p<0.001), qualitative analysis revealed lower image noise at 80 kVp images.
CONCLUSION: DECT at 80 kVp increases arterial enhancement in both CTPA and routine studies. For routine studies this results in central and peripheral enhancement quality equivalent to that of CTPA studies. Low tube-voltage imaging allows marked contrast volume reduction for CTPA. In selected cases, satisfactory lower radiation dose CT might be achievable using lower kVp imaging alone.
Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20149952     DOI: 10.1016/j.ejrad.2009.12.030

Source DB:  PubMed          Journal:  Eur J Radiol        ISSN: 0720-048X            Impact factor:   3.528


  12 in total

1.  Ultra-low dose contrast CT pulmonary angiography in oncology patients using a high-pitch helical dual-source technology.

Authors:  Prabhakar Rajiah; Leslie Ciancibello; Ronald Novak; Jennifer Sposato; Luis Landeras; Robert Gilkeson
Journal:  Diagn Interv Radiol       Date:  2019-05       Impact factor: 2.630

Review 2.  State of the art: utility of multi-energy CT in the evaluation of pulmonary vasculature.

Authors:  Prabhakar Rajiah; Yuki Tanabe; Sasan Partovi; Alastair Moore
Journal:  Int J Cardiovasc Imaging       Date:  2019-05-02       Impact factor: 2.357

3.  Spectral detector CT for cardiovascular applications.

Authors:  Prabhakar Rajiah; Suhny Abbara; Sandra Simon Halliburton
Journal:  Diagn Interv Radiol       Date:  2017 May-Jun       Impact factor: 2.630

4.  Clinical value of dual-energy spectral imaging with adaptive statistical iterative reconstruction for reducing contrast medium dose in CT portal venography: in comparison with standard 120-kVp imaging protocol.

Authors:  Chun-Ling Ma; Xiao-Xia Chen; Yu-Xin Lei; Xi-Rong Zhang; Yong-Jun Jia; Xin Tian; Qian Tian
Journal:  Br J Radiol       Date:  2016-03-31       Impact factor: 3.039

5.  Clinics in diagnostic imaging (152). Right lower lobe segmental pulmonary embolus.

Authors:  Jerome Irai Ezhil Bosco; Ree Nee Khoo; Wilfred C G Peh
Journal:  Singapore Med J       Date:  2014-05       Impact factor: 1.858

6.  Acute and subacute dual energy CT findings of pulmonary embolism in rabbits: correlation with histopathology.

Authors:  X Chai; L-J Zhang; B M Yeh; Y-E Zhao; X-B Hu; G-M Lu
Journal:  Br J Radiol       Date:  2011-07-26       Impact factor: 3.039

Review 7.  Dual-energy CT in pulmonary vascular disease.

Authors:  Ioannis Vlahos; Megan C Jacobsen; Myrna C Godoy; Konstantinos Stefanidis; Rick R Layman
Journal:  Br J Radiol       Date:  2021-09-24       Impact factor: 3.039

8.  What the Baby Formula and Medical Contrast Material Shortages Have in Common: Insights and Recommendations for Managing the Iodinated Contrast Media Shortage.

Authors:  Lakshmi Ananthakrishnan; Fernando U Kay; Eric A Zeikus; Eugene S Chu; Joseph Chang; John D Barr; Neil M Rofsky; Suhny Abbara
Journal:  Radiol Cardiothorac Imaging       Date:  2022-05-25

9.  CT angiography for pulmonary embolism in the emergency department: investigation of a protocol by 20 ml of high-concentration contrast medium.

Authors:  Mario Silva; Gianluca Milanese; Rocco Cobelli; Carmelinda Manna; Edoardo Rasciti; Sara Poggesi; Nicola Sverzellati
Journal:  Radiol Med       Date:  2019-10-28       Impact factor: 3.469

10.  CT pulmonary angiography in patients with acute or chronic renal insufficiency: Evaluation of a low dose contrast material protocol.

Authors:  Mathias Meyer; Holger Haubenreisser; Christoph Schabel; Christianne Leidecker; Bernhard Schmidt; Stefan O Schoenberg; Thomas Henzler
Journal:  Sci Rep       Date:  2018-01-31       Impact factor: 4.379

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.