Scanning orientation and polarization effects for XRQA radiochromic film.

Hani Alnawaf1, Martin J Butson, Tsang Cheung, Peter K N Yu.   

Abstract

Gafchromic XRQA radiochromic film, is an effective tool for quality assurance and dose assessment in kilovoltage radiotherapy and diagnostic applications. Like other Gafchromic film products, XRQA film exhibits a variation in dose to reflected optical density response with angle of rotation when analysed with a light source that is partially or fully polarised such as a desktop scanner. Although warnings are not given on manufacturers specifications, this can affect dosimetry accuracy and we recommend that it is essential to scan all XRQA films in the same orientation. The effect is not as pronounced as EBT Gafchromic film. The magnitude of this variation has been measured and shown to be up to 16 ± 2% (1SD) using a fully linear polarised light source was seen with a 90° angle rotation. This would be the maximum variation seen on a desktop scanner with a fully polarised light source. For our standard desktop scanner (Epson v700) a mean variation of 2 ± 1% from 0 cGy to 20 cGy applied dose was measured as compared to 8 ± 2% for EBT Gafchromic. We recommend that to decrease uncertainty in dose measurement, accurate alignment of the calibration films to experimental films be performed on a regular basis. This is especially important if your desktop scanner has a high degree of polarization of its light source.
Copyright © 2010 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2010        PMID: 20149701     DOI: 10.1016/j.ejmp.2010.01.003

Source DB:  PubMed          Journal:  Phys Med        ISSN: 1120-1797            Impact factor:   2.685


  3 in total

1.  How accurately can the peak skin dose in fluoroscopy be determined using indirect dose metrics?

Authors:  A Kyle Jones; Joe E Ensor; Alexander S Pasciak
Journal:  Med Phys       Date:  2014-07       Impact factor: 4.071

2.  The use of a thyroid shield for intraoral anterior oblique occlusal views-a risk-based approach.

Authors:  Mark Worrall; Alison Menhinick; Donald J Thomson
Journal:  Dentomaxillofac Radiol       Date:  2017-10-27       Impact factor: 2.419

3.  Effect of scanner lens on lateral response artefact in radiochromic film dosimetry.

Authors:  Tarafder Shameem; Nick Bennie; Martin Butson; David Thwaites
Journal:  Phys Eng Sci Med       Date:  2022-05-30
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.