Literature DB >> 20149682

Data-dependent neutral gain MS3: toward automated identification of the N-oxide functional group in drug metabolites.

Steven C Habicht1, Nelson R Vinueza, Penggao Duan, Mingkun Fu, Hilkka I Kenttämaa.   

Abstract

We report here an automated method for the identification of N-oxide functional groups in drug metabolites by using the combination of liquid chromatography/tandem mass spectrometry (LC/MS(n)) based on ion-molecule reactions and collision-activated dissociation (CAD). Data-dependent acquisition, which has been readily utilized for metabolite characterization using CAD-based methods, is adapted for use with ion-molecule reaction-based tandem mass spectrometry by careful choice of select experimental parameters. Two different experiments utilizing ion-molecule reactions are demonstrated, data-dependent neutral gain MS(3) and data-dependent neutral gain pseudo-MS(3), both of which generate functional group selective mass spectral data in a single experiment and facilitate increased throughput in structural elucidation of unknown mixture components. Initial results have been generated by using an LC/MS(n) method based on ion-molecule reactions developed earlier for the identification of the N-oxide functional group in pharmaceutical samples, a notoriously difficult functional group to identify via CAD alone. Since commercial software and straightforward, external instrument modification are used, these experiments are readily adaptable to the industrial pharmaceutical laboratory. 2010 American Society for Mass Spectrometry. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20149682     DOI: 10.1016/j.jasms.2009.12.015

Source DB:  PubMed          Journal:  J Am Soc Mass Spectrom        ISSN: 1044-0305            Impact factor:   3.109


  12 in total

Review 1.  Systematic LC/MS metabolite identification in drug discovery.

Authors:  N J Clarke; D Rindgen; W A Korfmacher; K A Cox
Journal:  Anal Chem       Date:  2001-08-01       Impact factor: 6.986

2.  Use of a quadrupole linear ion trap mass spectrometer in metabolite identification and bioanalysis.

Authors:  Yuan-Qing Xia; Jeffrey D Miller; Ray Bakhtiar; Ronald B Franklin; David Q Liu
Journal:  Rapid Commun Mass Spectrom       Date:  2003       Impact factor: 2.419

3.  Integration of knowledge-based metabolic predictions with liquid chromatography data-dependent tandem mass spectrometry for drug metabolism studies: application to studies on the biotransformation of indinavir.

Authors:  M Reza Anari; Rosa I Sanchez; Ray Bakhtiar; Ronald B Franklin; Thomas A Baillie
Journal:  Anal Chem       Date:  2004-02-01       Impact factor: 6.986

4.  Factors that affect ion trap data-dependent MS/MS in proteomics.

Authors:  Brett R Wenner; Bert C Lynn
Journal:  J Am Soc Mass Spectrom       Date:  2004-02       Impact factor: 3.109

5.  Rapid screening and characterization of drug metabolites using a new quadrupole-linear ion trap mass spectrometer.

Authors:  Gérard Hopfgartner; Christophe Husser; Manfred Zell
Journal:  J Mass Spectrom       Date:  2003-02       Impact factor: 1.982

6.  In vivo metabolite detection and identification in drug discovery via LC-MS/MS with data-dependent scanning and postacquisition data mining.

Authors:  Antonio Triolo; Maria Altamura; Tula Dimoulas; Antonio Guidi; Alessandro Lecci; Manuela Tramontana
Journal:  J Mass Spectrom       Date:  2005-12       Impact factor: 1.982

Review 7.  Application of mass spectrometry for metabolite identification.

Authors:  Shuguang Ma; Swapan K Chowdhury; Kevin B Alton
Journal:  Curr Drug Metab       Date:  2006-06       Impact factor: 3.731

Review 8.  Analytical strategies for identifying drug metabolites.

Authors:  Chandra Prakash; Christopher L Shaffer; Angus Nedderman
Journal:  Mass Spectrom Rev       Date:  2007 May-Jun       Impact factor: 10.946

9.  Profiling the metabolic difference of seven tanshinones using high-performance liquid chromatography/multi-stage mass spectrometry with data-dependent acquisition.

Authors:  Jianghao Sun; Min Yang; Jian Han; Baorong Wang; Xiaochi Ma; Man Xu; Peng Liu; Dean Guo
Journal:  Rapid Commun Mass Spectrom       Date:  2007       Impact factor: 2.419

10.  Unbiased high-throughput screening of reactive metabolites on the linear ion trap mass spectrometer using polarity switch and mass tag triggered data-dependent acquisition.

Authors:  Zhengyin Yan; Gary W Caldwell; Noureddine Maher
Journal:  Anal Chem       Date:  2008-07-19       Impact factor: 6.986

View more
  1 in total

1.  Advances in structure elucidation of small molecules using mass spectrometry.

Authors:  Tobias Kind; Oliver Fiehn
Journal:  Bioanal Rev       Date:  2010-08-21
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.