Literature DB >> 12577280

Rapid screening and characterization of drug metabolites using a new quadrupole-linear ion trap mass spectrometer.

Gérard Hopfgartner1, Christophe Husser, Manfred Zell.   

Abstract

The application of a new hybrid RF/DC quadrupole-linear ion trap mass spectrometer to support drug metabolism and pharmacokinetic studies is described. The instrument is based on a quadrupole ion path and is capable of conventional tandem mass spectrometry (MS/MS) as well as several high-sensitivity ion trap MS scans using the final quadrupole as a linear ion trap. Several pharmaceutical compounds, including trocade, remikiren and tolcapone, were used to evaluate the capabilities of the system with positive and negative turbo ionspray, using either information-dependent data acquisition (IDA) or targeted analysis for the screening, identification and quantification of metabolites. Owing to the MS/MS in-space configuration, quadrupole-like CID spectra with ion trap sensitivity can be obtained without the classical low mass cutoff of 3D ion traps. The system also has MS(3) capability which allows fragmentation cascades to be followed. The combination of constant neutral loss or precursor ion scan with the enhanced product ion scan was found to be very selective for identifying metabolites at the picogram level in very complex matrices. Owing to the very high cycle time and, depending on the mass range, up to eight different MS experiments could be performed simultaneously without compromising chromatographic performance. Targeted product ion analysis was found to be complementary to IDA, in particular for very low concentrations. Comparable sensitivity was found in enhanced product ion scan and selected reaction monitoring modes. The instrument is particularly suitable for both qualitative and quantitative analysis. Copyright 2003 John Wiley & Sons, Ltd.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12577280     DOI: 10.1002/jms.420

Source DB:  PubMed          Journal:  J Mass Spectrom        ISSN: 1076-5174            Impact factor:   1.982


  15 in total

1.  Mass selective axial ion ejection from a linear quadrupole ion trap.

Authors:  F A Londry; James W Hager
Journal:  J Am Soc Mass Spectrom       Date:  2003-10       Impact factor: 3.109

2.  Structural characterization of sulfadiazine metabolites using H/D exchange combined with various MS/MS experiments.

Authors:  Thomas Pfeifer; Jochen Tuerk; Regine Fuchs
Journal:  J Am Soc Mass Spectrom       Date:  2005-10       Impact factor: 3.109

3.  Mass selective ejection by axial resonant excitation from a linear ion trap.

Authors:  Yuichiro Hashimoto; Hideki Hasegawa; Takashi Baba; Izumi Waki
Journal:  J Am Soc Mass Spectrom       Date:  2006-03-09       Impact factor: 3.109

4.  Data-dependent neutral gain MS3: toward automated identification of the N-oxide functional group in drug metabolites.

Authors:  Steven C Habicht; Nelson R Vinueza; Penggao Duan; Mingkun Fu; Hilkka I Kenttämaa
Journal:  J Am Soc Mass Spectrom       Date:  2010-01-07       Impact factor: 3.109

5.  Characteristics of Ion Activation and Collision Induced Dissociation Using Digital Ion Trap Technology.

Authors:  Fuxing Xu; Qiankun Dang; Xinhua Dai; Xiang Fang; Yuanyuan Wang; Li Ding; Chuan-Fan Ding
Journal:  J Am Soc Mass Spectrom       Date:  2016-05-05       Impact factor: 3.109

6.  Rapid detection and identification of N-acetyl-L-cysteine thioethers using constant neutral loss and theoretical multiple reaction monitoring combined with enhanced product-ion scans on a linear ion trap mass spectrometer.

Authors:  Karoline Scholz; Wolfgang Dekant; Wolfgang Völkel; Axel Pähler
Journal:  J Am Soc Mass Spectrom       Date:  2005-10-24       Impact factor: 3.109

7.  Analysis of the in vitro metabolites of diferuloylmethane (curcumin) by liquid chromatography--tandem mass spectrometry on a hybrid quadrupole linear ion trap system: newly identified metabolites.

Authors:  Constantin Tamvakopoulos; Zacharias D Sofianos; Spiros D Garbis; Panayotis Pantazis
Journal:  Eur J Drug Metab Pharmacokinet       Date:  2007 Jan-Mar       Impact factor: 2.441

8.  Repetitive Aerosol Exposure Promotes Cavitary Tuberculosis and Enables Screening for Targeted Inhibitors of Extensive Lung Destruction.

Authors:  Michael E Urbanowski; Elizabeth A Ihms; Kristina Bigelow; André Kübler; Paul T Elkington; William R Bishai
Journal:  J Infect Dis       Date:  2018-06-05       Impact factor: 5.226

9.  An ion/molecule reaction for the identification of analytes with two basic functional groups.

Authors:  Mingkun Fu; Penggao Duan; Sen Li; Ryan J Eismin; Hilkka I Kenttämaa
Journal:  J Am Soc Mass Spectrom       Date:  2009-02-21       Impact factor: 3.109

10.  Induced in-source fragmentation pattern of certain novel (1Z,2E)-N-(aryl)propanehydrazonoyl chlorides by electrospray mass spectrometry (ESI-MS/MS).

Authors:  Ali S Abdelhameed; Mohamed W Attwa; Hatem A Abdel-Aziz; Adnan A Kadi
Journal:  Chem Cent J       Date:  2013-01-25       Impact factor: 4.215

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.