Literature DB >> 2014277

Dynamic gadolinium-enhanced rapid acquisition spin-echo MR imaging of the liver.

S A Mirowitz1, J K Lee, E Gutierrez, J J Brown, J P Heiken, S S Eilenberg.   

Abstract

Rapid acquisition spin-echo (RASE) magnetic resonance (MR) imaging allows for coverage of the entire liver with highly T1-weighted SE images during a single 23-second breath-holding period. The RASE sequence was implemented in conjunction with rapid intravenous injection of gadopentetate dimeglumine to enable performance of dynamic contrast material-enhanced MR imaging of the liver. Prospective evaluation of 24 patients with 62 liver lesions 1 cm or greater in diameter was performed. Images obtained with RASE were devoid of respiratory-related ghost artifacts or edge blurring. The dynamic contrast-enhanced RASE technique resulted in contrast-to-noise and contrast-to-artifact values and time efficiency measures significantly greater (P less than .05) than those obtained with use of conventional T1- and T2-weighted pulse sequences, indicating a higher likelihood for lesion detectability. Lesion conspicuity was maximal during or immediately following bolus administration of gadopentetate dimeglumine, with lesions often becoming obscured at delayed postcontrast imaging.

Entities:  

Mesh:

Substances:

Year:  1991        PMID: 2014277     DOI: 10.1148/radiology.179.2.2014277

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  8 in total

Review 1.  Ultra-high-speed MR imaging.

Authors:  C P Davis; G C McKinnon; J F Debatin; G K von Schulthess
Journal:  Eur Radiol       Date:  1996       Impact factor: 5.315

2.  MR imaging of focal liver lesions: comparison between turbo spin-echo and conventional spin-echo pulse sequences.

Authors:  A Giovagnoni; E Paci; P Ercolani; B Kiefer; P Santino; A Piga
Journal:  MAGMA       Date:  1995 Sep-Dec       Impact factor: 2.310

3.  Breath-hold spin-echo MR imaging for evaluation of dynamic enhancement of native and treated hepatocellular carcinoma after intravenous Gd-DTPA administration.

Authors:  R Lencioni; M Mascalchi; A Paolicchi; V Zampa
Journal:  MAGMA       Date:  1995 Sep-Dec       Impact factor: 2.310

4.  Hemodynamics of small hepatocellular carcinomas (5 cm or less in diameter): cases with discrepant findings between dynamic MR images and hepatic arteriograms.

Authors:  T Imaeda; R Mochizuki; M Kanematsu; Y Yamawaki; H Goto; M Seki; H Doi; S Saji; K Shimokawa
Journal:  Abdom Imaging       Date:  1995 Nov-Dec

5.  MRI characterization of 124 CT-indeterminate focal hepatic lesions: evaluation of clinical utility.

Authors:  Khaled M Elsayes; John R Leyendecker; Christine O Menias; Erica P Oliveira; Vamsidhar R Narra; William C Chapman; Moataz H Hassanien; Mohamed S Elsharkawy; Jeffrey J Brown
Journal:  HPB (Oxford)       Date:  2007       Impact factor: 3.647

6.  Contrast enhancement of the gastrointestinal tract on MR images using intravenous gadolinium-DTPA.

Authors:  S A Mirowitz
Journal:  Abdom Imaging       Date:  1993

7.  Comparison of the Timing of Hepatic Arterial Phase and Image Quality Using Test-Bolus and Bolus-Tracking Techniques in Gadolinium-Ethoxybenzyl-Diethylenetriamine Pentaacetic Acid-Enhanced Hepatic Dynamic Magnetic Resonance Imaging.

Authors:  Yuji Iyama; Takeshi Nakaura; Koichi Yokoyama; Masafumi Kidoh; Daisuke Utsunomiya; Seitaro Oda; Tomohiro Namimoto; Yasuyuki Yamashita
Journal:  J Comput Assist Tomogr       Date:  2017 Jul/Aug       Impact factor: 1.826

8.  Prospective comparative study of ability of MR imaging and other imaging modalities to localize tumors in patients with Zollinger-Ellison syndrome.

Authors:  J R Pisegna; J L Doppman; J A Norton; D C Metz; R T Jensen
Journal:  Dig Dis Sci       Date:  1993-07       Impact factor: 3.199

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.