Literature DB >> 20139562

A comparative study of inter-abutment distance of dies made from full arch dual-arch impression trays with those made from full arch stock trays: an in vitro study.

Jagan Mohan Reddy1, E Prashanti, G Vinay Kumar, M C Suresh Sajjan, Xavier Mathew.   

Abstract

OBJECTIVES: The dual-arch impression technique is convenient in that it makes the required maxillary and mandibular impressions, as well as the inter-occlusal record in one procedure. The accuracy of inter-abutment distance in dies fabricated from dual-arch impression technique remains in question because there is little information available in the literature.
MATERIALS AND METHODS: This study was conducted to evaluate the accuracy of inter-abutment distance in dies obtained from full arch dual-arch trays with those obtained from full arch stock metal trays. RESULTS AND
CONCLUSION: The metal dual-arch trays showed better accuracy followed by the plastic dual-arch and stock dentulous trays, respectively, though statistically insignificant. The pouring sequence did not have any effect on the inter-abutment distance statistically, though pouring the non-working side of the dual-arch impression first showed better accuracy.

Mesh:

Substances:

Year:  2009        PMID: 20139562     DOI: 10.4103/0970-9290.59437

Source DB:  PubMed          Journal:  Indian J Dent Res        ISSN: 0970-9290


  5 in total

1.  In vivo precision of conventional and digital methods for obtaining quadrant dental impressions.

Authors:  Andreas Ender; Moritz Zimmermann; Thomas Attin; Albert Mehl
Journal:  Clin Oral Investig       Date:  2015-11-07       Impact factor: 3.573

2.  Evaluation of dimensional stability and accuracy of autoclavable polyvinyl siloxane impression material.

Authors:  Subash M Reddy; D Vijitha; S Karthikeyan; R Balasubramanian; A Satish
Journal:  J Indian Prosthodont Soc       Date:  2012-08-07

3.  A Comparative Evaluation of Accuracy of the Dies Affected by Tray Type, Material Viscosity, and Pouring Sequence of Dual and Single Arch Impressions- An In vitro Study.

Authors:  Poonam R Kulkarni; Rahul S Kulkarni; Rupal J Shah; Rahul Chhajlani; Bhuwan Saklecha; Kavita Maru
Journal:  J Clin Diagn Res       Date:  2017-04-01

4.  Effect of Core Materials on the Dimensional Accuracy of Casts Made of Two Different Silicone Impression Materials: An Experimental Study.

Authors:  Mitra Farzin; Reza Derafshi; Rashin Giti; Mohammad-Hassan Kalantari
Journal:  J Int Soc Prev Community Dent       Date:  2020-03-05

5.  Need for a reliable alternative to custom-made Implant Impression trays: An in vitro study comparing accuracy of custom trays versus specialized aluminum stock tray.

Authors:  Mukti Goel; Pankaj Dhawan; Piyush Tandan; Pankaj Madhukar
Journal:  J Indian Prosthodont Soc       Date:  2018 Jul-Sep
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.