Literature DB >> 20139440

Automated border detection in three-dimensional echocardiography: principles and promises.

K Y Esther Leung1, Johan G Bosch.   

Abstract

Several automated border detection approaches for three-dimensional echocardiography have been developed in recent years, allowing quantification of a range of clinically important parameters. In this review, the background and principles of these approaches and the different classes of methods are described from a practical perspective, as well as the research trends to achieve a robust method.

Mesh:

Year:  2010        PMID: 20139440     DOI: 10.1093/ejechocard/jeq005

Source DB:  PubMed          Journal:  Eur J Echocardiogr        ISSN: 1532-2114


  15 in total

1.  Ultrasonic image analysis and image-guided interventions.

Authors:  J Alison Noble; Nassir Navab; H Becher
Journal:  Interface Focus       Date:  2011-06-15       Impact factor: 3.906

2.  Quantification of left ventricular volume and global function using a fast automated segmentation tool: validation in a clinical setting.

Authors:  Daniel Barbosa; Brecht Heyde; Thomas Dietenbeck; Helene Houle; Denis Friboulet; Olivier Bernard; Jan D'hooge
Journal:  Int J Cardiovasc Imaging       Date:  2012-08-01       Impact factor: 2.357

Review 3.  New developments in paediatric cardiac functional ultrasound imaging.

Authors:  Chris L de Korte; Maartje M Nillesen; Anne E C M Saris; Richard G P Lopata; Johan M Thijssen; Livia Kapusta
Journal:  J Med Ultrason (2001)       Date:  2013-12-20       Impact factor: 1.314

4.  The Role of Automated 3D Echocardiography for Left Ventricular Ejection Fraction Assessment.

Authors:  Ernest Spitzer; Ben Ren; Felix Zijlstra; Nicolas M Van Mieghem; Marcel L Geleijnse
Journal:  Card Fail Rev       Date:  2017-11

5.  Novel indices for left-ventricular dyssynchrony characterization based on highly automated segmentation from real-time 3-d echocardiography.

Authors:  Honghai Zhang; Ademola K Abiose; Dipti Gupta; Dwayne N Campbell; James B Martins; Milan Sonka; Andreas Wahle
Journal:  Ultrasound Med Biol       Date:  2012-11-08       Impact factor: 2.998

6.  Ventricular pressure-volume loops obtained by 3D real-time echocardiography and mini pressure wire-a feasibility study.

Authors:  Ulrike Herberg; Eva Gatzweiler; Thomas Breuer; Johannes Breuer
Journal:  Clin Res Cardiol       Date:  2013-02-09       Impact factor: 5.460

7.  Three-dimensional echocardiography using single-heartbeat modality decreases variability in measuring left ventricular volumes and function in comparison to four-beat technique in atrial fibrillation.

Authors:  Kambiz Shahgaldi; Aristomenis Manouras; Anna Abrahamsson; Petri Gudmundsson; Lars-Ake Brodin; Reidar Winter
Journal:  Cardiovasc Ultrasound       Date:  2010-10-05       Impact factor: 2.062

8.  Assessment of LV ejection fraction using real-time 3D echocardiography in daily practice: direct comparison of the volumetric and speckle tracking methodologies to CMR.

Authors:  M M P Driessen; E Kort; M J M Cramer; P A Doevendans; M J Angevaare; T Leiner; F J Meijboom; S A J Chamuleau; G Tj Sieswerda
Journal:  Neth Heart J       Date:  2014-09       Impact factor: 2.380

9.  A Hybrid Method for Endocardial Contour Extraction of Right Ventricle in 4-Slices from 3D Echocardiography Dataset.

Authors:  Faten A Dawood; Rahmita W Rahmat; Suhaini B Kadiman; Lili N Abdullah; Mohd D Zamrin
Journal:  Adv Bioinformatics       Date:  2014-10-12

10.  Robust myocardial motion tracking for echocardiography: variational framework integrating local-to-global deformation.

Authors:  Chi Young Ahn
Journal:  Comput Math Methods Med       Date:  2013-03-11       Impact factor: 2.238

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.