Abstract

BACKGROUND: In an attempt to improve the stent's safety, development of bare metal stents (BMS) continues, with new materials and geometry. Chrono (CID, Italy) is a thin strut cobalt-chromium (Co-Cr) stent combining the clinical benefits of the bio- and haemo-compatible Carbofilm coating.
METHODS: We assessed the safety and efficacy of percutaneous coronary interventions (PCI) using the new Co-Cr Chrono stent in patients undergoing elective PCI for de novo lesions in native coronary vessels. The patients were followed for 12 months for the occurrence of major cardiac events (MACE, defined as death, myocardial infarction, repeat PCI and bypass surgery). Patients with complex (B2/C) lesions were compared to those with non-complex lesions (A/B1).
RESULTS: A total of 340 consecutive patients were analysed: 155 patients with complex lesions (Complex group) and 185 patients with non-complex lesions (Non-complex group). Dual antiplatelet therapy was maintained >1 month in 21% of patients in both Complex and Non-complex group. Stent length was longer in the Complex group (25 ± 10 mm versus 17 ± 6 mm; p<0.001). Stent diameter <3.0 mm was most frequent in the Complex group (35.5% versus 27.5%; p<0.05). During the 12-month follow-up period MACE occurred in 10.6% of the global population (12.3% in the Complex group and 9.2% in the Non-complex group; p=0.43). Repeat PCI was most frequent in the Complex group (9.7% versus 3.8%; p=0.044). The incidence of definite and probable stent thrombosis (ARC criteria) was 1.29% in the Complex group and 1.08% in the Non-complex group (p=1.0).
CONCLUSIONS: Implantation of the Co-Cr Chrono stent results in a good safety and efficacy for both complex and non-complex de-novo coronary artery lesions.
Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20138377     DOI: 10.1016/j.ijcard.2010.01.009

Source DB:  PubMed          Journal:  Int J Cardiol        ISSN: 0167-5273            Impact factor:   4.164


  3 in total

Review 1.  The Newest Generation of Drug-eluting Stents and Beyond.

Authors:  Dae-Hyun Lee; Jose M de la Torre Hernandez
Journal:  Eur Cardiol       Date:  2018-08

2.  Real world experience with an indigenously manufactured stent Cobal C--a retrospective study.

Authors:  B K S Sastry; Nirmal Kumar; Rajeev Menon; Anuj Kapadia; C Sridevi; G Surya Prakash; N Krishna Reddy; M Srinivasa Rao
Journal:  Indian Heart J       Date:  2014-09-18

Review 3.  Health Care Monitoring and Treatment for Coronary Artery Diseases: Challenges and Issues.

Authors:  Mokhalad Alghrairi; Nasri Sulaiman; Saad Mutashar
Journal:  Sensors (Basel)       Date:  2020-08-01       Impact factor: 3.576

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.