Literature DB >> 2013592

Anterior spinal fixation after lumbar corpectomy. A study in dogs.

T A Zdeblick1, O Shirado, P C McAfee, H deGroot, K E Warden.   

Abstract

An animal model was developed to simulate an unstable lumbar burst fracture that had been treated with corpectomy. A fifth lumbar laminectomy, partial facetectomy, and corpectomy was performed in twenty-one dogs. In seven dogs (the control group), a biodegradable polymer spacer was used to create a definite failure of fusion (Group I). Seven dogs were treated with a traditional anterior arthrodesis with an autogenous ulnar strut and without instrumentation (Group II). The remaining seven dogs were treated with an ulnar strut and anterior Kaneda instrumentation that was of an appropriate size for the dog (Group III). At twenty-four weeks, the results were analyzed in terms of the rate of fusion, biomechanical rigidity, neuropathological findings, and histomorphometric data on the vertebral response. The rate of fusion was significantly higher in Group III, in which the Kaneda device had been used, than it was in either Group I or Group II, in which instrumentation had not been used. Biomechanically, the spines in Group III were stiffer in torsion than those in Group I or II. There was no difference between groups in terms of the number of neuropathological changes in the spinal cord. Histomorphometric analysis showed that no meaningful device-related osteopenia occurred in the vertebrae that were spanned by the fixation device. Trabecular density was increased in the vertebrae in which the instrumentation was anchored.

Entities:  

Mesh:

Year:  1991        PMID: 2013592

Source DB:  PubMed          Journal:  J Bone Joint Surg Am        ISSN: 0021-9355            Impact factor:   5.284


  5 in total

1.  Thoracolumbar fracture stabilization: comparative biomechanical evaluation of a new video-assisted implantable system.

Authors:  M Schultheiss; E Hartwig; L Kinzl; L Claes; H-J Wilke
Journal:  Eur Spine J       Date:  2003-11-22       Impact factor: 3.134

2.  Solvent-preserved, bovine cancellous bone blocks used for reconstruction of thoracolumbar fractures in minimally invasive spinal surgery-first clinical results.

Authors:  Markus Schultheiss; Michael Sarkar; Markus Arand; Michael Kramer; Hans-Joachim Wilke; Lothar Kinzl; Erich Hartwig
Journal:  Eur Spine J       Date:  2004-07-10       Impact factor: 3.134

3.  Load-displacement properties of the thoracolumbar calf spine: experimental results and comparison to known human data.

Authors:  H J Wilke; S T Krischak; K H Wenger; L E Claes
Journal:  Eur Spine J       Date:  1997       Impact factor: 3.134

4.  Single stage corpectomy and instrumentation in the treatment of pathological fractures in the lumbar spine.

Authors:  Stefan M Knoeller; Oliver Huwert; Tilman Wolter
Journal:  Int Orthop       Date:  2011-06-04       Impact factor: 3.075

5.  Evaluation of an artificial vertebral body fabricated by a tantalum-coated porous titanium scaffold for lumbar vertebral defect repair in rabbits.

Authors:  Faqi Wang; Lin Wang; Yafei Feng; Xiaojiang Yang; Zhensheng Ma; Lei Shi; Xiangyu Ma; Jian Wang; Tiancheng Ma; Zhao Yang; Xinxin Wen; Yang Zhang; Wei Lei
Journal:  Sci Rep       Date:  2018-06-12       Impact factor: 4.379

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.