Literature DB >> 20134081

Scatter correction in digital mammography based on image deconvolution.

J L Ducote1, S Molloi.   

Abstract

X-ray scatter is a major cause of nonlinearity in densitometry measurements using digital mammography. Previous scatter correction techniques have primarily used a single scatter point spread function to estimate x-ray scatter. In this study, a new algorithm to correct x-ray scatter based on image convolution was implemented using a spatially variant scatter point spread function which is energy and thickness dependent. The scatter kernel was characterized in terms of its scattering fraction (SF) and scatter radial extent (k) on uniform Lucite phantoms with thickness of 0.8-8.0 cm. The algorithm operates on a pixel-by-pixel basis by grouping pixels of similar thicknesses into a series of mask images that are individually deconvolved using Fourier image analysis with a distinct kernel for each image. The algorithm was evaluated with three Lucite step phantoms and one anthropomorphic breast phantom using a full-field digital mammography system at energies of 24, 28, 31 and 49 kVp. The true primary signal was measured with a multi-hole collimator. The effect on image quality was also evaluated. For all 16 studies, the average mean percentage error in estimating the true primary signal was found to be -2.13% and the average rms percentage error was 2.60%. The image quality was seen to improve at every energy up to 25% at 49 kVp. The results indicate that a technique based on a spatially variant scatter point spread function can accurately estimate x-ray scatter.

Mesh:

Year:  2010        PMID: 20134081     DOI: 10.1088/0031-9155/55/5/003

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  7 in total

1.  Quantification of breast density with spectral mammography based on a scanned multi-slit photon-counting detector: a feasibility study.

Authors:  Huanjun Ding; Sabee Molloi
Journal:  Phys Med Biol       Date:  2012-07-06       Impact factor: 3.609

2.  On image quality metrics and the usefulness of grids in digital mammography.

Authors:  Han Chen; Mats Danielsson; Cheng Xu; Björn Cederström
Journal:  J Med Imaging (Bellingham)       Date:  2015-02-17

3.  Assessment of coronary microcirculation in a swine animal model.

Authors:  Zhang Zhang; Shigeho Takarada; Sabee Molloi
Journal:  Am J Physiol Heart Circ Physiol       Date:  2011-05-27       Impact factor: 4.733

4.  Quantification of breast density with dual energy mammography: an experimental feasibility study.

Authors:  Justin L Ducote; Sabee Molloi
Journal:  Med Phys       Date:  2010-02       Impact factor: 4.071

5.  Quantification of coronary microvascular resistance using angiographic images for volumetric blood flow measurement: in vivo validation.

Authors:  Zhang Zhang; Shigeho Takarada; Sabee Molloi
Journal:  Am J Physiol Heart Circ Physiol       Date:  2011-03-11       Impact factor: 4.733

6.  Volumetric lean percentage measurement using dual energy mammography.

Authors:  Justin L Ducote; Michael J Klopfer; S Molloi
Journal:  Med Phys       Date:  2011-08       Impact factor: 4.071

7.  A new method to correct the attenuation map in simultaneous transmission/emission tomography using Gd/Ga radioisotopes.

Authors:  Subhash Chand Kheruka; Brian F Hutton; Umesh Chand Naithani; Lalit Mohan Aggarwal; Nirmal Kumar Painuly; Anil Kumar Maurya; Sanjay Gambhir
Journal:  J Med Phys       Date:  2012-01
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.