Literature DB >> 20128581

Assessment and comparison of anterior chamber dimensions using various imaging techniques.

Umut Asli Dinc1, Banu Oncel, Ebru Gorgun, Melda Nursal Yenerel, Levent Alimgil.   

Abstract

BACKGROUND AND
OBJECTIVE: To assess and compare the horizontal dimensions of the anterior chamber by different anterior segment imaging techniques. PATIENTS AND METHODS: Eighty eyes of 40 patients without any ocular disease or previous ocular surgery were recruited and three consecutive measurements of internal anterior chamber diameter and white-to-white distance (WTW) parameters were determined.
RESULTS: Mean internal anterior chamber diameter was 11.80 +/- 0.39, 11.56 +/- 0.47, and 11.61 +/- 0.58 mm with Visante-OCT, SL-OCT, and Pentacam, respectively. Mean WTW distance was 11.87 +/- 0.35 and 11.65 +/- 0.32 mm by IOLMaster and OrbscanIIz, respectively. There was no significant difference between Visante-OCT and Pentacam, IOLMaster, and OrbscanIIz (P = .125, .918, and .314). However, detection of mean internal anterior chamber diameter was significantly greater by Visante-OCT than SL-OCT (P = .026). All devices displayed a high intrasession repeatability (repeated measured ANOVA, P > .05).
CONCLUSION: Internal anterior chamber diameter measurements using Visante-OCT, SL-OCT, and Pentacam, and WTW measurements using IOLMaster and OrbscanIIz were easy to handle and demonstrated good repeatability. Although similar results of horizontal anterior chamber diameter were determined by Visante-OCT, Pentacam, IOLMaster, and OrbscanIIz, the inter-device differences should be considered during clinical practice. Copyright 2010, SLACK Incorporated.

Entities:  

Mesh:

Year:  2010        PMID: 20128581     DOI: 10.3928/15428877-20091230-21

Source DB:  PubMed          Journal:  Ophthalmic Surg Lasers Imaging        ISSN: 1542-8877


  3 in total

1.  [Biometry of the anterior eye segment for implantation of phakic anterior chamber lenses. A comparison of current measurement devices].

Authors:  L Kiraly; G Duncker
Journal:  Ophthalmologe       Date:  2012-03       Impact factor: 1.059

2.  White-to-white corneal diameter: normal values in healthy Iranian population obtained with the Orbscan II.

Authors:  Hamid Gharaee; Mojtaba Abrishami; Masoud Shafiee; Asieh Ehsaei
Journal:  Int J Ophthalmol       Date:  2014-04-18       Impact factor: 1.779

3.  Comparison of Anterior Segment Measurements with a New Multifunctional Unit and Five Other Devices.

Authors:  Bo Yi Kim; Ikhyun Jun
Journal:  Korean J Ophthalmol       Date:  2022-06-15
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.