Masahiko Koda1, Mari Mandai, Tomomitu Matono, Takaaki Sugihara, Takakazu Nagahara, Masaru Ueki, Kenji Ohyama, Keiko Hosho, Yoshikazu Murawaki.
Abstract
This study investigated whether contrast-enhanced sonography can accurately predict the ablated area by radiofrequency ablation using virtual sonography by computed tomography as a gold standard. Thirty-one hepatocellular carcinoma nodules were treated by radiofrequency ablation and then examined. The defect of contrast-enhanced sonography (puncture direction: r=.868, P<.0001; perpendicular direction; r=.925, P<.0001) was closely correlated with the unenhanced area of virtual sonography. Contrast-enhanced sonography can be used for early and accurate prediction of the ablated area and is helpful for assessing local control of radiofrequency ablation. Copyright 2010 Elsevier Inc. All rights reserved.Entities:
Mesh:
Substances:
Year: 2010 PMID: 20122522 DOI: 10.1016/j.clinimag.2009.03.006