Clinical feasibility of a fully automated 3D reconstruction of rotational coronary X-ray angiograms.

Anne M Neubauer1, Joel A Garcia, John C Messenger, Eberhard Hansis, Michael S Kim, Andrew J P Klein, Gert A F Schoonenberg, Michael Grass, John D Carroll.   

Abstract

BACKGROUND: Although fixed view x-ray angiography remains the primary technique for anatomic imaging of coronary artery disease, the known shortcomings of 2D projection imaging may limit accurate 3D vessel and lesion definition and characterization. A recently developed method to create 3D images of the coronary arteries uses x-ray projection images acquired during a 180 degrees C-arm rotation and continuous contrast injection followed by ECG-gated iterative reconstruction. This method shows promise for providing high-quality 3D reconstructions of the coronary arteries with no user interaction but requires clinical evaluation. METHODS AND
RESULTS: The reconstruction strategy was evaluated by comparing the reconstructed 3D volumetric images with the 2D angiographic projection images from the same 23 patients to ascertain overall image quality, lesion visibility, and a comparison of 3D quantitative coronary analysis with 2D quantitative coronary analysis. The majority of the resulting 3D volume images were rated as having high image quality (66%) and provided the physician with additional clinical information such as complete visualization of bifurcations and unobtainable views of the coronary tree. True-positive lesion detection rates were high (90 to 100%), whereas false-positive detection rates were low (0 to 8.1%). Finally, 3D quantitative coronary analysis showed significant similarity with 2D quantitative coronary analysis in terms of lumen diameters and provided vessel segment length free from the errors of foreshortening.
CONCLUSIONS: Fully automated reconstruction of rotational coronary x-ray angiograms is feasible, produces 3D volumetric images that overcome some of the limitations of standard 2D angiography, and is ready for further implementation and study in the clinical environment.

Entities:  

Mesh:

Year:  2010        PMID: 20118152     DOI: 10.1161/CIRCINTERVENTIONS.109.897629

Source DB:  PubMed          Journal:  Circ Cardiovasc Interv        ISSN: 1941-7640            Impact factor:   6.546


  8 in total

1.  Optimization of acquisition and contrast injection protocol for C-arm CT imaging in transcatheter aortic valve implantation: initial experience in a swine model.

Authors:  Uma D Numburi; Samir R Kapadia; Paul Schoenhagen; E Murat Tuzcu; Martin von Roden; Sandra S Halliburton
Journal:  Int J Cardiovasc Imaging       Date:  2012-06-20       Impact factor: 2.357

2.  Case Report: Percutaneous Closure of an Ascending Aortic Pseudoaneurysm by 3D Angiography Guidance.

Authors:  C Huie Lin; Joshua Murphy; David T Balzer
Journal:  Methodist Debakey Cardiovasc J       Date:  2015 Apr-Jun

Review 3.  Potential role of three-dimensional rotational angiography and C-arm CT for valvular repair and implantation.

Authors:  Jonathan G Schwartz; Anne M Neubauer; Thomas E Fagan; Niels J Noordhoek; Michael Grass; John D Carroll
Journal:  Int J Cardiovasc Imaging       Date:  2011-03-11       Impact factor: 2.357

4.  Calibration-free device sizing using an inverse geometry x-ray system.

Authors:  Michael T Tomkowiak; Michael A Speidel; Amish N Raval; Michael S Van Lysel
Journal:  Med Phys       Date:  2011-01       Impact factor: 4.071

5.  Local motion-compensated method for high-quality 3D coronary artery reconstruction.

Authors:  Bo Liu; Xiangzhi Bai; Fugen Zhou
Journal:  Biomed Opt Express       Date:  2016-11-23       Impact factor: 3.732

6.  The role of computed tomography in pre-procedural planning of cardiovascular surgery and intervention.

Authors:  Prabhakar Rajiah; Paul Schoenhagen
Journal:  Insights Imaging       Date:  2013-08-02

7.  Automatic vasculature identification in coronary angiograms by adaptive geometrical tracking.

Authors:  Ruoxiu Xiao; Jian Yang; Mahima Goyal; Yue Liu; Yongtian Wang
Journal:  Comput Math Methods Med       Date:  2013-10-22       Impact factor: 2.238

8.  The importance of three dimensional coronary artery reconstruction accuracy when computing virtual fractional flow reserve from invasive angiography.

Authors:  Roshni Solanki; Rebecca Gosling; Vignesh Rammohan; Giulia Pederzani; Pankaj Garg; James Heppenstall; D Rodney Hose; Patricia V Lawford; Andrew J Narracott; John Fenner; Julian P Gunn; Paul D Morris
Journal:  Sci Rep       Date:  2021-10-04       Impact factor: 4.996

  8 in total