Coronary angiography and percutaneous transluminal coronary angioplasty procedures: Evaluation of patients' maximum skin dose using Gafchromic films and a comparison of local levels with reference levels proposed in the literature.

C Giordano1, L D'Ercole, R Gobbi, M Bocchiola, F Passerini.   

Abstract

The aim of this study was to evaluate the maximum skin dose (MSD) in patients undergoing interventional cardiology procedures, obtaining local reference levels and comparing these with the reference levels proposed in the literature. The patients' MSD was measured using Gafchromic XR type R films. In order to evaluate reference levels, the number of images acquired, the fluoroscopy times and the KAP(TOTAL) were recorded for each procedure. For the evaluation of the MSD, 8 coronary angiography (CA) and 16 percutaneous transluminal coronary angioplasty (PTCA) procedures, carried out in the period from May to June 2008, were analyzed. For the CA procedures the MSD values were below 0.5 Gy. For the PTCA procedures, we found a fairly good correlation between fluoroscopy time and MSD (r = 0.80, p = 0.0002) and between MSD and WFP (r = 0.863, p < 0.0001); there was a strong correlation between KAP(TOTAL) and MSD (r = 0.904, p <0.0001). Since the correlation between KAP(TOTAL) and MSD is more striking than that with fluoroscopic time and the WFP, KAP measurements are suitable for online skin dosimetry and may, therefore, be used to avoid radiation-induced skin injuries. A MSD greater than 3 Gy occurred in only one procedure. For calculus of the local reference levels, we extended the data-gathering to 30 procedure CA and to 40 PTCA: we compared local practice with that in other centers using the guidance levels proposed by Balter et al. Our median KAP values were below these proposed guidance levels; our mean KAP values were above these proposed action levels. From a first application of the proposed reference levels, it appears that, according to the recommendations of Balter et al. an investigation into local practice is not necessary.
Copyright © 2010 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2010        PMID: 20117030     DOI: 10.1016/j.ejmp.2010.01.001

Source DB:  PubMed          Journal:  Phys Med        ISSN: 1120-1797            Impact factor:   2.685


  2 in total

Review 1.  Reduction of Radiation Risk to Interventional Cardiologists and Patients during Angiography and Coronary Angioplasty.

Authors:  Mohsen Mohammadi; Leili Danaee; Effat Alizadeh
Journal:  J Tehran Heart Cent       Date:  2017-07

2.  Dual-axis rotational coronary angiography can reduce peak skin dose and scattered dose: a phantom study.

Authors:  Huiliang Liu; Zhigeng Jin; Yunpeng Deng; Limin Jing
Journal:  J Appl Clin Med Phys       Date:  2014-07-08       Impact factor: 2.102

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.