Biomechanical comparison of biomimetically and electrochemically deposited hydroxyapatite-coated porous titanium implants.

Guo-li Yang1, Fu-ming He, Ji-an Hu, Xiao-xiang Wang, Shi-fang Zhao.   

Abstract

PURPOSE: The purpose of this study was to investigate the effects of biomimetically and electrochemically deposited hydroxyapatite on the fixation of an implant with bone tissue.
MATERIALS AND METHODS: Implants were separated into 3 groups: roughened group, biomimetically deposited calcium-phosphorus (BDCaP) group, and electrochemically deposited hydroxyapatite (EDHA) group. We randomly inserted 90 implants into the femurs of 45 rabbits. After 2, 4, and 8 weeks, the femurs were retrieved and prepared for removal torque tests (RTQs) and field-emission scanning electron microscopy observation.
RESULTS: During the test period, the EDHA group showed significantly greater RTQ values than did the roughened group and BDCaP group. The BDCaP group failed to increase the RTQ values compared with the roughened group. Field-emission scanning electron microscopy observation showed that the amount of attached bone tissue on the EDHA-coated implant surface was more than that on the roughened and BDCaP-coated implant surfaces during the test period.
CONCLUSION: The electrochemical hydroxyapatite coating contributes to the fixation between bone and implant compared with the roughened surface, whereas the biomimetic calcium-phosphorus coating has little effect on the fixation. Copyright 2010 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20116717     DOI: 10.1016/j.joms.2009.09.014

Source DB:  PubMed          Journal:  J Oral Maxillofac Surg        ISSN: 0278-2391            Impact factor:   1.895


  9 in total

1.  Osseointegration of polyethylene implants coated with titanium and biomimetically or electrochemically deposited hydroxyapatite in a rabbit model.

Authors:  Caroline Scemama; Bertrand David; Morad Bensidhoum; Moussa Hamadouche
Journal:  Int Orthop       Date:  2014-05-24       Impact factor: 3.075

2.  Bone ingrowth potential of electron beam and selective laser melting produced trabecular-like implant surfaces with and without a biomimetic coating.

Authors:  J E Biemond; G Hannink; N Verdonschot; P Buma
Journal:  J Mater Sci Mater Med       Date:  2012-12-21       Impact factor: 3.896

3.  Bone regeneration in critically sized rat mandible defects through the endochondral pathway using hydroxyapatite-coated 3D-printed Ti6Al4V scaffolds.

Authors:  Yan Wang; Xinjie Cai; Jing Huang; Yi Zhou; Tao Jiang; Yining Wang
Journal:  RSC Adv       Date:  2018-09-12       Impact factor: 4.036

4.  Effects of zinc-substituted nano-hydroxyapatite coatings on bone integration with implant surfaces.

Authors:  Shi-fang Zhao; Wen-jing Dong; Qiao-hong Jiang; Fu-ming He; Xiao-xiang Wang; Guo-li Yang
Journal:  J Zhejiang Univ Sci B       Date:  2013-06       Impact factor: 3.066

5.  Behavior of rat bone marrow stem cells on titanium surfaces modified by laser-beam and deposition of calcium phosphate.

Authors:  F Florian; F P S Guastaldi; M A Cominotte; L C Pires; A C Guastaldi; J A Cirelli
Journal:  J Mater Sci Mater Med       Date:  2021-05-17       Impact factor: 3.896

6.  A prospective randomized study comparing electrochemically deposited hydroxyapatite and plasma-sprayed hydroxyapatite on titanium stems.

Authors:  Berte Grimsmo Bøe; Stephan M Röhrl; Tore Heier; Finnur Snorrason; Lars Nordsletten
Journal:  Acta Orthop       Date:  2010-12-29       Impact factor: 3.717

7.  Influence of simvastatin-loaded implants on osseointegration in an ovariectomized animal model.

Authors:  Wen Fang; Shifang Zhao; Fuming He; Li Liu; Guoli Yang
Journal:  Biomed Res Int       Date:  2015-03-29       Impact factor: 3.411

8.  Micro-Arc Oxidation Enhances the Blood Compatibility of Ultrafine-Grained Pure Titanium.

Authors:  Lin Xu; Kun Zhang; Cong Wu; Xiaochun Lei; Jianning Ding; Xingling Shi; Chuncheng Liu
Journal:  Materials (Basel)       Date:  2017-12-19       Impact factor: 3.623

9.  Comparison of sandblasted and acid-etched surface implants and new hydrophilic surface implants in the posterior maxilla using a 3-month early-loading protocol: a randomized controlled trial.

Authors:  Hyeong Gi Kim; Pil-Young Yun; Young-Kyun Kim; Il-Hyung Kim
Journal:  J Korean Assoc Oral Maxillofac Surg       Date:  2021-06-30
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.