Literature DB >> 20113847

Dental unit waterlines: source of contamination and cross-infection.

S Kumar1, D Atray, D Paiwal, G Balasubramanyam, P Duraiswamy, S Kulkarni.   

Abstract

Dental chair units (DCUs) are used in the treatment of many patients throughout each day and microbial contamination of specific component parts is an important potential source of cross-infection. The quality of dental unit water is of considerable importance since patients and dental staff are regularly exposed to water and aerosols generated from the dental unit. This water hosts a diverse microflora of bacteria, yeasts, fungi, viruses, protozoa, unicellular algae and nematodes which may be contaminated with micro-organisms found in the biofilm formed due to water stagnation in the narrow-bore dental unit waterline (DUWL) tubings. The water thus contaminated, when used for various treatment procedures through dental handpieces, air/water/three-in-one syringe, etc., produces aerosols that can cause infection. The present review emphasises the risks of infection from DUWL and various water treatment procedures available to disinfect the DUWLs.

Entities:  

Mesh:

Year:  2010        PMID: 20113847     DOI: 10.1016/j.jhin.2009.03.027

Source DB:  PubMed          Journal:  J Hosp Infect        ISSN: 0195-6701            Impact factor:   3.926


  8 in total

Review 1.  A scoping review on bio-aerosols in healthcare and the dental environment.

Authors:  Charifa Zemouri; Hans de Soet; Wim Crielaard; Alexa Laheij
Journal:  PLoS One       Date:  2017-05-22       Impact factor: 3.240

2.  Microbial contamination of dental unit waterlines and effect on quality of indoor air.

Authors:  Duygu Göksay Kadaifciler; Aysin Cotuk
Journal:  Environ Monit Assess       Date:  2014-01-28       Impact factor: 2.513

3.  Bacterial contamination of dental unit waterlines.

Authors:  Jolanta Szymańska; Jolanta Sitkowska
Journal:  Environ Monit Assess       Date:  2012-08-17       Impact factor: 2.513

Review 4.  Mechanized scaling with ultrasonics: Perils and proactive measures.

Authors:  Rashmi Paramashivaiah; M L V Prabhuji
Journal:  J Indian Soc Periodontol       Date:  2013-07

5.  Risk assessment for the spread of Candida sp. in dental chair unit waterlines using molecular techniques.

Authors:  Wissame Mazari; Zahia Boucherit-Otmani; Imad Abdelhamid El Haci; Amine Ilahi; Kebir Boucherit
Journal:  Int Dent J       Date:  2018-05-04       Impact factor: 2.607

6.  A survey of the bacterial diversity in the cup filler of dental chair units.

Authors:  Vítor Silva; Vânia Figueira; Helena Figueiral; Célia M Manaia
Journal:  Braz J Microbiol       Date:  2011-09-01       Impact factor: 2.476

7.  Substantivity of hypochlorous acid-based disinfectant against biofilm formation in the dental unit waterlines.

Authors:  Irfana Fathima Shajahan; Deivanayagam Kandaswamy; L Lakshminarayanan; R Selvarajan
Journal:  J Conserv Dent       Date:  2017 Jan-Feb

8.  Evaluation of the spatter-reduction effectiveness of two dry-field isolation techniques.

Authors:  William O Dahlke; Michael R Cottam; Matthew C Herring; Joshua M Leavitt; Marcia M Ditmyer; Richard S Walker
Journal:  J Am Dent Assoc       Date:  2012-11       Impact factor: 3.634