A prototype scintillation dosimeter customized for small and dynamic megavoltage radiation fields.

Jamil Lambert1, Yongbai Yin, David R McKenzie, Susan H Law, Anna Ralston, Natalka Suchowerska.   

Abstract

A prototype plastic scintillation dosimeter has been developed with a small sensitive volume, rapid response and good dosimetric performance. The novelty of this design is the use of an air core light guide to transport the scintillation signal out of the primary radiation field. The significance of this innovation is that it eliminates the Cerenkov background signal that is generated in conventional optical fibres. The dosimeter performance was compared to existing commercial dosimeters in 6 MV and 18 MV photon beams and 6 MeV and 20 MeV electron beams, in both static and dynamic fields. The dosimeter was tested in small static fields and in dynamically delivered fields where the detector volume is shielded, while the stem is irradiated. The depth dose measurements for the photon beams agreed with ionization chamber measurements to within 1.6%, except in the build-up region due to positional uncertainty. For the 6 MeV and 20 MeV electron beams, the percentage depth dose measurements agreed with the ionization chamber measurements to within 3.6% and 4.5%, respectively. For field sizes of 1 cm x 1 cm and greater, the air core dosimeter readings agreed with diamond detector readings to within 1.2%. The air core dosimeter was accurate in dynamically delivered fields and had no measurable stem effect. The air core dosimeter was accurate over a range of field sizes, energies and dose rates, confirming that it is a sensitive and accurate dosimeter with high spatial resolution suitable for use in megavoltage photon and electron beams.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20107251     DOI: 10.1088/0031-9155/55/4/014

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  6 in total

1.  Extraction of depth-dependent perturbation factors for parallel-plate chambers in electron beams using a plastic scintillation detector.

Authors:  Frédéric Lacroix; Mathieu Guillot; Malcolm McEwen; Claudiu Cojocaru; Luc Gingras; A Sam Beddar; Luc Beaulieu
Journal:  Med Phys       Date:  2010-08       Impact factor: 4.071

2.  Spectral method for the correction of the Cerenkov light effect in plastic scintillation detectors: a comparison study of calibration procedures and validation in Cerenkov light-dominated situations.

Authors:  Mathieu Guillot; Luc Gingras; Louis Archambault; Sam Beddar; Luc Beaulieu
Journal:  Med Phys       Date:  2011-04       Impact factor: 4.071

Review 3.  A review of recent advances in optical fibre sensors for in vivo dosimetry during radiotherapy.

Authors:  S O'Keeffe; D McCarthy; P Woulfe; M W D Grattan; A R Hounsell; D Sporea; L Mihai; I Vata; G Leen; E Lewis
Journal:  Br J Radiol       Date:  2015-03-11       Impact factor: 3.039

4.  Validating plastic scintillation detectors for photon dosimetry in the radiologic energy range.

Authors:  Francois Lessard; Louis Archambault; Mathieu Plamondon; Philippe Despres; Franccois Therriault-Proulx; Sam Beddar; Luc Beaulieu
Journal:  Med Phys       Date:  2012-09       Impact factor: 4.071

5.  Two-dimensional real-time quality assurance dosimetry system using μ-Al2O3:C,Mg radioluminescence films.

Authors:  Luana F Nascimento; Dirk Verellen; Jo Goossens; Lara Struelens; Filip Vanhavere; Paul Leblans; Mark Akselrod
Journal:  Phys Imaging Radiat Oncol       Date:  2020-10-05

6.  Small field detector correction factors: effects of the flattening filter for Elekta and Varian linear accelerators.

Authors:  Madelaine K Tyler; Paul Z Y Liu; Christopher Lee; David R McKenzie; Natalka Suchowerska
Journal:  J Appl Clin Med Phys       Date:  2016-05-08       Impact factor: 2.102

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.