Literature DB >> 20103798

Role of sonographic automatic volume calculation in measuring fetal cardiac ventricular volumes using 4-dimensional sonography: comparison with virtual organ computer-aided analysis.

Giuseppe Rizzo1, Alessandra Capponi, Maria Elena Pietrolucci, Domenico Arduini.   

Abstract

OBJECTIVE: The purpose of this study was to compare the agreement and reliability of virtual organ computer-aided analysis (VOCAL) and sonographic automatic volume calculation (sonoAVC) for measurements of ventricular volume from fetal heart data sets acquired by 4-dimensional sonography with spatiotemporal image correlation (STIC).
METHODS: We studied 45 volumes from fetuses with normal (n = 30) and abnormal (n = 15) hearts. Spatiotemporal image correlation data sets were frozen in end systole and end diastole, and ventricular volumes were measured with VOCAL and sonoAVC. The stroke volume was calculated from these measurements. Reliability and agreement of the two techniques were evaluated with intraclass correlation coefficients (ICCs), and proportionate Bland-Altman plots were constructed. The time necessary to complete the measurements with either technique was compared. Intraobserver and interobserver agreement of measurements was calculated.
RESULTS: All data sets could be measured with both techniques. A high degree of reliability was observed between VOCAL and sonoAVC (left ventricular stroke volume ICC, 0.978; 95% confidence interval [CI], 0.957-0.989; right ventricular stroke volume ICC, 0.985; 95% CI, 0.972-0.992). The time necessary to measure the stroke volume was significantly shorter with sonoAVC (2.8 versus 11.7 minutes; P < .0001) than with VOCAL. Bland-Altman tests showed no clinically significant mean percent differences between stroke volume measurements obtained from each ventricle by the same observer or by 2 independent observers using either VOCAL or sonoAVC.
CONCLUSIONS: There was good agreement between cardiac volumes measured with VOCAL and sonoAVC. Sonographic automatic volume calculation represents a rapid technique for estimating fetal stroke volume and promises to become the method of choice.

Entities:  

Mesh:

Year:  2010        PMID: 20103798     DOI: 10.7863/jum.2010.29.2.261

Source DB:  PubMed          Journal:  J Ultrasound Med        ISSN: 0278-4297            Impact factor:   2.153


  8 in total

1.  Prospective evaluation of the fetal heart using Fetal Intelligent Navigation Echocardiography (FINE).

Authors:  M Garcia; L Yeo; R Romero; D Haggerty; I Giardina; S S Hassan; T Chaiworapongsa; E Hernandez-Andrade
Journal:  Ultrasound Obstet Gynecol       Date:  2016-03-10       Impact factor: 7.299

2.  The fetal cardiovascular response to increased placental vascular impedance to flow determined with 4-dimensional ultrasound using spatiotemporal image correlation and virtual organ computer-aided analysis.

Authors:  Neil Hamill; Roberto Romero; Sonia Hassan; Wesley Lee; Stephen A Myers; Pooja Mittal; Juan Pedro Kusanovic; Mamtha Balasubramaniam; Tinnakorn Chaiworapongsa; Edi Vaisbuch; Jimmy Espinoza; Francesca Gotsch; Luis F Goncalves; Shali Mazaki-Tovi; Offer Erez; Edgar Hernandez-Andrade; Lami Yeo
Journal:  Am J Obstet Gynecol       Date:  2012-12-07       Impact factor: 8.661

Review 3.  Fetal cardiac function by three-dimensional ultrasound using 4D-STIC and VOCAL - an update.

Authors:  Nathalie Jeanne Bravo-Valenzuela; Alberto Borges Peixoto; Milene Carvalho Carrilho; Ana Letícia Siqueira Pontes; Caroline Cevante Chagas; Christiane Simioni; Edward Araujo Júnior
Journal:  J Ultrason       Date:  2019-12-31

4.  Development and Testing of an Ultrasound-Compatible Cardiac Phantom for Interventional Procedure Simulation Using Direct Three-Dimensional Printing.

Authors:  Shu Wang; Yohan Noh; Jemma Brown; Sébastien Roujol; Ye Li; Shuangyi Wang; Richard Housden; Mar Casajuana Ester; Maleha Al-Hamadani; Ronak Rajani; Kawal Rhode
Journal:  3D Print Addit Manuf       Date:  2020-12-16       Impact factor: 5.449

Review 5.  4D imaging of fetal right ventricle-feasibility study and a review of the literature.

Authors:  M Pasieczna; J Duliban; A Grzyb; J Szymkiewicz-Dangel
Journal:  Int J Cardiovasc Imaging       Date:  2021-09-20       Impact factor: 2.357

6.  Real-time 3-dimensional echocardiographic assessment of ventricular volume, mass, and function in human fetuses.

Authors:  Minjuan Zheng; Micheal Schaal; Yan Chen; Xiaokui Li; Weihui Shentu; Pengyuan Zhang; Muhammad Ashraf; Shuping Ge; David J Sahn
Journal:  PLoS One       Date:  2013-03-14       Impact factor: 3.240

7.  Evaluation of right ventricular function in fetal hypoplastic left heart syndrome using spatio-temporal image correlation (STIC).

Authors:  Jing Zhang; Qichang Zhou; Yili Zhao; Qinghai Peng; Zheli Gong; Xiangdang Long
Journal:  Cardiovasc Ultrasound       Date:  2016-04-11       Impact factor: 2.062

8.  Novel foetal echocardiographic image processing software (5D Heart) improves the display of key diagnostic elements in foetal echocardiography.

Authors:  Wan-Yu Hu; Jin-Hong Zhou; Xiao-Ying Tao; Shi-Yan Li; Bei Wang; Bo-Wen Zhao
Journal:  BMC Med Imaging       Date:  2020-04-03       Impact factor: 1.930

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.