Literature DB >> 20103205

Effect of prosthesis-patient mismatch on long-term survival with aortic valve replacement: assessment to 15 years.

W R Eric Jamieson1, Jian Ye, Jennifer Higgins, Anson Cheung, Guy J Fradet, Peter Skarsgard, Eva Germann, Florence Chan, Samuel V Lichtenstein.   

Abstract

BACKGROUND: The effect of prosthesis-patient mismatch on long-term survival after aortic valve replacement has received considerable attention but there remains controversy. This study was performed to determine the predictors of mortality after aortic valve replacement and influence of prosthesis-patient mismatch on survival.
METHODS: Contemporary mechanical prostheses and bioprostheses were implanted in 3,343 patients with aortic valve replacement between 1982 and 2003. The mean age was 68.06 +/- 11.20 years (median 70.06; range, 19 to 94), and the mean follow-up was 6.18 +/- 4.96 years, for a total of 20,666 years of follow-up. Prosthesis-patient mismatch was classified by effective orifice area index categories: normal (> 0.85 cm(2)/m(2)), 1,547 (46.3%); mild-to-moderate (> 0.65 cm(2)/m(2) to < or = 0.85 cm(2)/m(2)), 1,584 (47.4%); and severe (< 0.65 cm(2)/m(2)), 212 (6.3%).
RESULTS: The predictors of overall mortality were age, age categorization, New York Heart Association functional class III/IV, concomitant coronary artery bypass graft surgery, prosthesis type, preoperative congestive heart failure, diabetes mellitus, renal failure, and chronic obstructive pulmonary disease. All categories of effective orifice area indexes were not predictive of overall mortality, late mortality, or early mortality. The 15-year overall survival was differentiated by effective orifice area index categories: 38.1% +/- 2.1%, 37.0% +/- 2.2%, and 22.1% +/- 6.5%, respectively, for the three categories. Survival adjusted for the covariates (effective orifice area index, age, basal mass index, and ejection fraction) determined no effect except severe effective orifice area index when adjusted for ejection fraction more than 50% (p = 0.049).
CONCLUSIONS: Prosthesis-patient mismatch is not a predictor of overall standard unadjusted mortality to 15 years after aortic valve replacement, regardless of the category of effective orifice area index. 2010 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2010        PMID: 20103205     DOI: 10.1016/j.athoracsur.2009.08.070

Source DB:  PubMed          Journal:  Ann Thorac Surg        ISSN: 0003-4975            Impact factor:   4.330


  14 in total

Review 1.  Prosthesis-patient mismatch: an update.

Authors:  Jean G Dumesnil; Philippe Pibarot
Journal:  Curr Cardiol Rep       Date:  2011-06       Impact factor: 2.931

2.  Cardiac energetics analysis after aortic valve replacement with 16-mm ATS mechanical valve.

Authors:  Tomoki Ushijima; Yoshihisa Tanoue; Takayuki Uchida; Sho Matsuyama; Takashi Matsumoto; Ryuji Tominaga
Journal:  J Artif Organs       Date:  2014-05-25       Impact factor: 1.731

Review 3.  Prosthesis-patient mismatch in aortic stenosis.

Authors:  Kentaro Honda; Yoshitaka Okamura
Journal:  Gen Thorac Cardiovasc Surg       Date:  2013-10-17

4.  Incidence and Impact of Patient-Prosthesis Mismatch in Isolated Aortic Valve Surgery.

Authors:  Selman Dumani; Ermal Likaj; Andi Kacani; Laureta Dibra; Elizana Petrela; Vera Beca; Ali Refatllari
Journal:  Open Access Maced J Med Sci       Date:  2015-10-15

5.  Patient prosthesis mismatch after aortic valve replacement: An Indian perspective.

Authors:  Shreedhar S Joshi; T Ashwini; Antony George; A M Jagadeesh
Journal:  Ann Card Anaesth       Date:  2016 Jan-Mar

6.  Impact of prosthesis-patient mismatch on early and late mortality after aortic valve replacement.

Authors:  Bart M Koene; Mohamed A Soliman Hamad; Wobbe Bouma; Massimo A Mariani; Kathinka C Peels; Jan-Melle van Dantzig; Albert H van Straten
Journal:  J Cardiothorac Surg       Date:  2013-04-17       Impact factor: 1.637

7.  Patient-prosthesis mismatch in patients with aortic valve replacement.

Authors:  Yuichiro Kaminishi; Yoshio Misawa; Junjiro Kobayashi; Hiroaki Konishi; Hiroaki Miyata; Noboru Motomura; Shin-ichi Takamoto
Journal:  Gen Thorac Cardiovasc Surg       Date:  2013-02-13

8.  Seventeen-millimeter St. Jude Medical Regent valve in patients with small aortic annulus: dose moderate prosthesis-patient mismatch matter?

Authors:  Jia Hu; Hong Qian; Ya-jiao Li; Jun Gu; Jing Janice Zhao; Er-yong Zhang
Journal:  J Cardiothorac Surg       Date:  2014-01-17       Impact factor: 1.637

9.  Trends in mechanical aortic valve replacement surgery in a large, multi-surgeon, single hospital practice.

Authors:  Mehmet Kalender; Ali Fedakar; Taylan Adademir; Salih Salihi; Kamil Boyacıoğlu; Babürhan Özbek; Mehmet Taşar; Mehmet Balkanay
Journal:  Kardiochir Torakochirurgia Pol       Date:  2014-11-30

10.  Moderate Patient-Prosthesis Mismatch Has No Negative Effect on Patients' Functional Status After Aortic Valve Replacement With CarboMedics Prosthesis.

Authors:  Alireza Alizadeh-Ghavidel; Rasoul Azarfarin; Azin Alizadehasl; Ali Sadeghpour-Tabaei; Ziae Totonchi
Journal:  Res Cardiovasc Med       Date:  2016-03-05
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.