Literature DB >> 20099372

Repeatability of DTI-based skeletal muscle fiber tracking.

Anneriet M Heemskerk1, Tuhin K Sinha, Kevin J Wilson, Zhaohua Ding, Bruce M Damon.   

Abstract

Diffusion tensor imaging (DTI)-based muscle fiber tracking enables the measurement of muscle architectural parameters, such as pennation angle (theta) and fiber tract length (L(ft)), throughout the entire muscle. Little is known, however, about the repeatability of either the muscle architectural measures or the underlying diffusion measures. Therefore, the goal of this study was to investigate the repeatability of DTI fiber tracking-based measurements and theta and L(ft). Four DTI acquisitions were performed on two days that allowed for between acquisition, within day, and between day analyses. The eigenvalues and fractional anisotropy were calculated at the maximum cross-sectional area of, and fiber tracking was performed in, the tibialis anterior muscle of nine healthy subjects. The between acquisitions condition had the highest repeatability for the DTI indices and the architectural parameters. The overall inter class correlation coefficients (ICC's) were greater than 0.6 for both theta and L(ft) and the repeatability coefficients were theta < 10.2 degrees and L(ft) < 50 mm. In conclusion, under the experimental and data analysis conditions used, the repeatability of the diffusion measures is very good and repeatability of the architectural measurements is acceptable. Therefore, this study demonstrates the feasibility for longitudinal studies of alterations in muscle architecture using DTI-based fiber tracking, under similar noise conditions and with similar diffusion characteristics. 2010 John Wiley & Sons, Ltd.

Entities:  

Mesh:

Year:  2010        PMID: 20099372      PMCID: PMC4416059          DOI: 10.1002/nbm.1463

Source DB:  PubMed          Journal:  NMR Biomed        ISSN: 0952-3480            Impact factor:   4.044


  43 in total

1.  Fascicle length of leg muscles is greater in sprinters than distance runners.

Authors:  T Abe; K Kumagai; W F Brechue
Journal:  Med Sci Sports Exerc       Date:  2000-06       Impact factor: 5.411

Review 2.  Measuring agreement in medical informatics reliability studies.

Authors:  George Hripcsak; Daniel F Heitjan
Journal:  J Biomed Inform       Date:  2002-04       Impact factor: 6.317

Review 3.  Fiber tracking: principles and strategies - a technical review.

Authors:  Susumu Mori; Peter C M van Zijl
Journal:  NMR Biomed       Date:  2002 Nov-Dec       Impact factor: 4.044

4.  Evaluation of diffusional anisotropy and microscopic structure in skeletal muscles using magnetic resonance.

Authors:  Takako Saotome; Masaki Sekino; Fumio Eto; Shoogo Ueno
Journal:  Magn Reson Imaging       Date:  2005-12-19       Impact factor: 2.546

5.  Effects of signal-to-noise ratio on the accuracy and reproducibility of diffusion tensor imaging-derived fractional anisotropy, mean diffusivity, and principal eigenvector measurements at 1.5 T.

Authors:  Jonathan A D Farrell; Bennett A Landman; Craig K Jones; Seth A Smith; Jerry L Prince; Peter C M van Zijl; Susumu Mori
Journal:  J Magn Reson Imaging       Date:  2007-09       Impact factor: 4.813

6.  Muscle fiber length and moment arm coordination during dorsi- and plantarflexion in the mouse hindlimb.

Authors:  R L Lieber
Journal:  Acta Anat (Basel)       Date:  1997

7.  Statistical methods for assessing agreement between two methods of clinical measurement.

Authors:  J M Bland; D G Altman
Journal:  Lancet       Date:  1986-02-08       Impact factor: 79.321

8.  DTI-based assessment of ischemia-reperfusion in mouse skeletal muscle.

Authors:  Anneriet M Heemskerk; Maarten R Drost; Glenda S van Bochove; Matthijs F M van Oosterhout; Klaas Nicolay; Gustav J Strijkers
Journal:  Magn Reson Med       Date:  2006-08       Impact factor: 4.668

Review 9.  Functional and clinical significance of skeletal muscle architecture.

Authors:  R L Lieber; J Fridén
Journal:  Muscle Nerve       Date:  2000-11       Impact factor: 3.217

10.  Quantitative assessment of DTI-based muscle fiber tracking and optimal tracking parameters.

Authors:  Anneriet M Heemskerk; Tuhin K Sinha; Kevin J Wilson; Zhaohua Ding; Bruce M Damon
Journal:  Magn Reson Med       Date:  2009-02       Impact factor: 4.668

View more
  28 in total

1.  Polynomial fitting of DT-MRI fiber tracts allows accurate estimation of muscle architectural parameters.

Authors:  Bruce M Damon; Anneriet M Heemskerk; Zhaohua Ding
Journal:  Magn Reson Imaging       Date:  2012-04-12       Impact factor: 2.546

2.  Clinical application of diffusion tensor magnetic resonance imaging in skeletal muscle.

Authors:  Xu Longwei
Journal:  Muscles Ligaments Tendons J       Date:  2012-06-17

3.  Combined diffusion and strain tensor MRI reveals a heterogeneous, planar pattern of strain development during isometric muscle contraction.

Authors:  Erin K Englund; Christopher P Elder; Qing Xu; Zhaohua Ding; Bruce M Damon
Journal:  Am J Physiol Regul Integr Comp Physiol       Date:  2011-01-26       Impact factor: 3.619

4.  Contemporary image-based methods for measuring passive mechanical properties of skeletal muscles in vivo.

Authors:  Lynne E Bilston; Bart Bolsterlee; Antoine Nordez; Shantanu Sinha
Journal:  J Appl Physiol (1985)       Date:  2018-09-20

5.  Determination of three-dimensional muscle architectures: validation of the DTI-based fiber tractography method by manual digitization.

Authors:  P Schenk; T Siebert; P Hiepe; D Güllmar; J R Reichenbach; C Wick; R Blickhan; M Böl
Journal:  J Anat       Date:  2013-05-16       Impact factor: 2.610

6.  Multi-parametric MRI characterization of healthy human thigh muscles at 3.0 T - relaxation, magnetization transfer, fat/water, and diffusion tensor imaging.

Authors:  Ke Li; Richard D Dortch; E Brian Welch; Nathan D Bryant; Amanda K W Buck; Theodore F Towse; Daniel F Gochberg; Mark D Does; Bruce M Damon; Jane H Park
Journal:  NMR Biomed       Date:  2014-07-26       Impact factor: 4.044

Review 7.  Skeletal Muscle Quantitative Nuclear Magnetic Resonance Imaging and Spectroscopy as an Outcome Measure for Clinical Trials.

Authors:  Pierre G Carlier; Benjamin Marty; Olivier Scheidegger; Paulo Loureiro de Sousa; Pierre-Yves Baudin; Eduard Snezhko; Dmitry Vlodavets
Journal:  J Neuromuscul Dis       Date:  2016-03-03

8.  Time-dependent diffusion in skeletal muscle with the random permeable barrier model (RPBM): application to normal controls and chronic exertional compartment syndrome patients.

Authors:  Eric E Sigmund; Dmitry S Novikov; Dabang Sui; Obehi Ukpebor; Steven Baete; James S Babb; Kecheng Liu; Thorsten Feiweier; Jane Kwon; Kellyanne McGorty; Jenny Bencardino; Els Fieremans
Journal:  NMR Biomed       Date:  2014-03-09       Impact factor: 4.044

9.  Reproducibility analysis of diffusion tensor indices and fiber architecture of human calf muscles in vivo at 1.5 Tesla in neutral and plantarflexed ankle positions at rest.

Authors:  Shantanu Sinha; Usha Sinha
Journal:  J Magn Reson Imaging       Date:  2011-05-23       Impact factor: 4.813

10.  Stimulated echo diffusion tensor imaging and SPAIR T2 -weighted imaging in chronic exertional compartment syndrome of the lower leg muscles.

Authors:  Eric E Sigmund; Dabang Sui; Obehi Ukpebor; Steven Baete; Els Fieremans; James S Babb; Michael Mechlin; Kecheng Liu; Jane Kwon; KellyAnne McGorty; Philip A Hodnett; Jenny Bencardino
Journal:  J Magn Reson Imaging       Date:  2013-02-25       Impact factor: 4.813

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.