Literature DB >> 20099035

In vitro comparison of the effect of stent configuration on wall shear stress using time-resolved particle image velocimetry.

John Charonko1, Satyaprakash Karri, Jaime Schmieg, Santosh Prabhu, Pavlos Vlachos.   

Abstract

Time resolved particle image velocimetry was used to measure wall shear stress (WSS) and oscillatory shear index (OSI) within a 3.0 mm diameter compliant vessel model implanted with an Abbott Vascular XIENCE V stent in five configurations: baseline, over-expanded, increased vessel diameter, two overlapped stents, and increased stent length. Flow through unstented vessels was also tested for comparison. Flow conditions featured a realistic coronary pressure-flow offset and reversal at average flow rates corresponding to resting (Re=160, f=70 bpm) and exercise conditions (Re=300, f=120 bpm). Comparisons revealed that the WSS was similar for all cases behind the first strut and downstream of the device, indicating that changes in configuration have little effect downstream. However, there were notable differences within each stent revealing reduced WSS values for all cases due to the stent-imposed expansion of the vessel wall (0.20-9.29 dynes/cm2 for Re=160 and d=3.0 mm). Over-expanding the stent with a second balloon affected the alignment of the stent geometry, and led to higher WSS at the inlet and lower values at mid-stent. The overlapped stents showed disturbed flow and a WSS deficit region downstream of the overlapped region. Analysis of the longer stent showed that the WSS within the vessel recovers with distance. An overall correlation was noted between decreased WSS values and elevated OSI. Results of this study are important because decreased WSS has been implicated in endothelial cell changes and increased restenosis, and clinical research has shown that a link exists between deployment configurations and negative patient outcomes.

Entities:  

Mesh:

Year:  2010        PMID: 20099035     DOI: 10.1007/s10439-010-9915-7

Source DB:  PubMed          Journal:  Ann Biomed Eng        ISSN: 0090-6964            Impact factor:   3.934


  2 in total

Review 1.  Endovascular stent-induced alterations in host artery mechanical environments and their roles in stent restenosis and late thrombosis.

Authors:  Jinxuan Wang; Xuepu Jin; Yuhua Huang; Xiaolin Ran; Desha Luo; Dongchuan Yang; Dongyu Jia; Kang Zhang; Jianhua Tong; Xiaoyan Deng; Guixue Wang
Journal:  Regen Biomater       Date:  2018-05-02

2.  The Time-Domain Integration Method of Digital Subtraction Angiography Images.

Authors:  Shuo Huang; Le Cheng; Bin Zhu; Ping Zhou; Yu Sun; Bing Zhang; Suiren Wan
Journal:  Comput Math Methods Med       Date:  2018-09-30       Impact factor: 2.238

  2 in total