Literature DB >> 20091101

The effect of gamma irradiation on physical-mechanical properties and cytotoxicity of polyurethane-polydimethylsiloxane microfibrillar vascular grafts.

Enrica Briganti1, Tamer Al Kayal, Silvia Kull, Paola Losi, Dario Spiller, Sara Tonlorenzi, Debora Berti, Giorgio Soldani.   

Abstract

Poly(ether) urethane (PEtU)-polydimethylsiloxane (PDMS) based materials have been processed by a spray, phase-inversion technique to produce microfibrillar small-diameter vascular grafts; however the effect of sterilization upon these grafts is still unknown. This study investigated the effect of gamma irradiation on grafts made of PEtU-PDMS materials containing different PDMS concentrations. Sterilisation-induced changes in surface chemical structure and morphology were assessed by infrared spectroscopy, light and scanning electron microscopy. Tensile tests were used to examine changes in mechanical properties and the cytotoxicity evaluation was performed on L929 fibroblasts. The study demonstrated that physical-chemical and mechanical properties of PEtU-PDMS grafts, at each PDMS concentration, were not significantly affected by the exposure to gamma irradiation, moreover no sign of cytotoxicity was observed after sterilisation. Although in vitro experiments have been promising, further in vivo studies are necessary to evaluate the biodegradation behaviour of PEtU-PDMS graft after gamma irradiation, before any clinical application.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 20091101     DOI: 10.1007/s10856-009-3943-6

Source DB:  PubMed          Journal:  J Mater Sci Mater Med        ISSN: 0957-4530            Impact factor:   3.896


  19 in total

1.  Isolation of methylene dianiline and aqueous-soluble biodegradation products from polycarbonate-polyurethanes.

Authors:  Y W Tang; R S Labow; J P Santerre
Journal:  Biomaterials       Date:  2003-08       Impact factor: 12.479

2.  Improved technique for polytetrafluoroethylene bypass grafting: long-term results using anastomotic vein patches.

Authors:  R S Taylor; A Loh; R J McFarland; M Cox; J F Chester
Journal:  Br J Surg       Date:  1992-04       Impact factor: 6.939

3.  In vitro experiments and in vivo implants to evaluate a new silicone-based polyurethane material for replacement of small vessels.

Authors:  Giorgio Soldani; Massimo Bernabei; Paola Losi; Adrian Crucean; Dante Chiappino; Silvia Burchielli; Fabio Bernini
Journal:  Cardiol Young       Date:  2004       Impact factor: 1.093

Review 4.  Polyurethane elastomer biostability.

Authors:  K Stokes; R McVenes; J M Anderson
Journal:  J Biomater Appl       Date:  1995-04       Impact factor: 2.646

5.  Light microscopy evaluation of polyurethane vascular grafts porosity by Sudan Black B staining.

Authors:  G Soldani; P Losi; C Milioni; A Raffi
Journal:  J Microsc       Date:  2002-05       Impact factor: 1.758

6.  Effect of different gamma-irradiation doses on cytotoxicity and material properties of porous polyether-urethane polymer.

Authors:  H J Haugen; M Brunner; F Pellkofer; J Aigner; J Will; E Wintermantel
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2007-02       Impact factor: 3.368

7.  Penetrating micropores increase patency and achieve extensive endothelialization in small diameter polymer skin coated vascular grafts.

Authors:  T Okoshi; G Soldani; M Goddard; P M Galletti
Journal:  ASAIO J       Date:  1996 Sep-Oct       Impact factor: 2.872

8.  Microporous small diameter PVDF-TrFE vascular grafts fabricated by a spray phase inversion technique.

Authors:  T Okoshi; H Chen; G Soldani; P M Galletti; M Goddard
Journal:  ASAIO J       Date:  1992 Jul-Sep       Impact factor: 2.872

9.  Silicone based polyurethane materials: a promising biocompatible elastomeric formulation for cardiovascular applications.

Authors:  E Briganti; P Losi; A Raffi; M Scoccianti; A Munaò; G Soldani
Journal:  J Mater Sci Mater Med       Date:  2006-03       Impact factor: 3.896

10.  Effect of hand segment chemistry and strain on the stability of polyurethanes: in vivo biostability.

Authors:  R W Hergenrother; H D Wabers; S L Cooper
Journal:  Biomaterials       Date:  1993-05       Impact factor: 12.479

View more
  2 in total

1.  Development and evaluation of elastomeric hollow fiber membranes as small diameter vascular graft substitutes.

Authors:  Ángel E Mercado-Pagán; Yunqing Kang; Michael W Findlay; Yunzhi Yang
Journal:  Mater Sci Eng C Mater Biol Appl       Date:  2015-01-15       Impact factor: 7.328

2.  Reconfigurable Microfluidic Magnetic Valve Arrays: Towards a Radiotherapy-Compatible Spheroid Culture Platform for the Combinatorial Screening of Cancer Therapies.

Authors:  Alexandre R Brunet; Frédérique Labelle; Philip Wong; Thomas Gervais
Journal:  Sensors (Basel)       Date:  2017-10-04       Impact factor: 3.576

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.