Literature DB >> 2008890

Bending properties of superelastic and nonsuperelastic nickel-titanium orthodontic wires.

S E Khier1, W A Brantley, R A Fournelle.   

Abstract

Cantilever bending properties were evaluated for several clinically popular sizes of three superelastic and three nonsuperelastic brands of nickel-titanium orthodontic wires in the as-received condition, and for 0.016-inch diameter wires after heat treatment at 500 degrees and at 600 degrees C, for 10 minutes and for 2 hours. A torque meter apparatus was used for the bending experiments, and the specimen test-span length was 1/4 inch (6 mm). In general, the bending properties were similar for the three brands of superelastic wires and for the three brands of nonsuperelastic wires. For the three brands of superelastic wires, heat treatment at 500 degrees C for 10 minutes had minimal effect on the bending plots, whereas heat treatment at 500 degrees C for 2 hours caused decreases in the average superelastic bending moment during deactivation; heat treatment at 600 degrees C resulted in loss of superelasticity. The bending properties for the three brands of nonsuperelastic wires were only slightly affected by these heat treatments. The differences in the bending properties and heat treatment responses are attributed to the relative proportions of the austenitic and martensitic forms of nickel-titanium alloy (NiTi) in the microstructures of the wire alloys.

Entities:  

Mesh:

Substances:

Year:  1991        PMID: 2008890     DOI: 10.1016/0889-5406(91)70013-M

Source DB:  PubMed          Journal:  Am J Orthod Dentofacial Orthop        ISSN: 0889-5406            Impact factor:   2.650


  11 in total

1.  Deformation of nickel-titanium closed coil springs: an in vitro study.

Authors:  Camilla Ivini Viana Vieira; José Maurício Dos Santos Nunes Reis; Luiz Geraldo Vaz; Lídia Parsekian Martins; Renato Parsekian Martins
Journal:  Dental Press J Orthod       Date:  2017-02

2.  Superelasticity and force plateau of nickel-titanium springs: an in vitro study.

Authors:  Camila Ivini Viana Vieira; Sergei Godeiro Fernandes Rabelo Caldas; Lídia Parsekian Martins; Renato Parsekian Martins
Journal:  Dental Press J Orthod       Date:  2016-06

3.  Pain and discomfort experienced after placement of a conventional or a superelastic NiTi aligning archwire. A randomized clinical trial.

Authors:  L M Fernandes; B Ogaard; L Skoglund
Journal:  J Orofac Orthop       Date:  1998       Impact factor: 1.938

4.  Flexural properties of rectangular nickel-titanium orthodontic wires when used as ribbon archwires.

Authors:  Li Lin; G Fräns Currier; Onur Kadioglu; Fernando L Esteban Florez; David M Thompson; Sharukh S Khajotia
Journal:  Angle Orthod       Date:  2018-08-03       Impact factor: 2.079

5.  Torsional superelasticity of NiTi archwires.

Authors:  Yves Bolender; Anne Vernière; Christophe Rapin; Marie-Pierryle Filleul
Journal:  Angle Orthod       Date:  2010-11       Impact factor: 2.079

6.  A clinical comparison of three aligning archwires in terms of alignment efficiency: A prospective clinical trial.

Authors:  Reem Sh Abdelrahman; Kazem S Al-Nimri; Emad F Al Maaitah
Journal:  Angle Orthod       Date:  2014-08-04       Impact factor: 2.079

7.  The influence of distal-end heat treatment on deflection of nickel-titanium archwire.

Authors:  Marcelo Faria da Silva; Célia Regina Maia Pinzan-Vercelino; Júlio de Araújo Gurgel
Journal:  Dental Press J Orthod       Date:  2016 Jan-Feb

8.  DSC analysis and evaluation of forces released on deactivation of 0.40-mm (0.016") orthodontic thermo-activated NiTi wires: An in vitro study.

Authors:  Vítor Marques Sapata; Diogo Marques Sapata; Julio Araújo Gurgel; Antônio Medina Neto; Adilson Luiz Ramos
Journal:  J Dent Res Dent Clin Dent Prospects       Date:  2020

9.  Effect of saliva on load-deflection characteristics of superelastic nickel-titanium orthodontic wires.

Authors:  T Hosseinzadeh Nik; H Ghadirian; M Nili Ahmadabadi; T Shahhoseini; M Haj-Fathalian
Journal:  J Dent (Tehran)       Date:  2012-12-31

10.  Comparison of the superelasticity of different nickel-titanium orthodontic archwires and the loss of their properties by heat treatment.

Authors:  Humberto Bellini; Javier Moyano; Javier Gil; Andreu Puigdollers
Journal:  J Mater Sci Mater Med       Date:  2016-09-13       Impact factor: 3.896

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.